OMRON G5LA14CFDC24

G5LA
PCB Power Relay
A Cubic, Single-pole 10A
Power Relay
• Economical cube relay with universal terminal footprint
• Conforms to VDE0435
• UL recognized/CSA certified.
• High switching power: 10A @ 250VAC
• Withstands impulse of up to 4,500V
• Coil power consumption: 360mW
• UL Class F coil insulation type also available
• Tracking resistance: CTI>250
RoHS Compliant
■Model Number Legend
■Application Examples
• Home appliance
G 5 L A -@ @ @ - @ - @
1 2 3
4
• OA equipments
5
1. Number of poles
1:
1-pole
2. Contact Form
None: SPDT (1c)
A:
SPST-NO (1a)
3. Enclosure rating
None: Flux protection
4:
Fully sealed
4. Classification
None: Standard
E:
High capacity (NC side)
G
5
L
A
• Vending machines, etc.
5. UL Insulation System
None: Standard
CF:
Class F
■Ordering Information
Classification
Terminal Shape
Contact form
SPST-NO (1a)
Standard
PCB terminals
High-capacity
SPDT (1c)
SPDT (1c)
Enclosure rating
Model
Flux protection
G5LA-1A(-CF)
Fully-sealed
G5LA-1A4(-CF)
Flux protection
G5LA-1(-CF)
Fully-sealed
G5LA-14(-CF)
Flux protection
G5LA-1-E(-CF)
Fully-sealed
G5LA-14-E(-CF)
Rated coil voltage
5VDC
9VDC
12VDC
24VDC
48VDC
Minimum packing unit
100 pcs/tray
Note. When ordering, add the rated coil voltage to the model number.
Example: G5LA-1 DC 12
Rated coil voltage
■Ratings
●Coil
Rated voltage
(VDC)
Rated current
(mA)
Coil
resistance
(Ω)
5
72
69.4
9
40
225
12
30
400
24
15
1600
48
10
4800
Must operate voltage
(V)
Must release voltage
(V)
Max. voltage
(V)
% of rated voltage
75% max.
10% min.
130% (at 85°C)
170% (at 23°C)
Power
consumption
(mW)
Approx. 360
Approx. 480
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±10%.
2. Please avoid ultrasonic cleaning this relay.
1
G5LA
PCB Power Relay
●Contacts
Item
Standard model
Contact material
Ag-alloy (Cd free)
Load
Resistive load (cosφ=1)
High-capacity (-E) model
NO
10A at 250VAC
10A at 24VDC
NO/NC
5A/5A at 125VAC
5A/5A at 24VDC
5A/5A at 250VAC
5A/5A at 24VDC
Rate carry current
10A (NO), 5A (NC)
10A
Max. switching voltage
250VAC, 24VDC
Max. switching current
10A (NO), 5A (NC)
Rated load
NO
AC2,500VA, DC240W
NO/NC
AC625VA, DC120W
10A
Max. switching power
Failure rate (reference value)
AC1,250VAC, DC120W
100mA at 5VDC
-5
Note. P level: λ60 = 0.1 x 10 /operation
■Characteristics
G
5
L
A
Contact resistance
100 mΩ max.
Operate time
10 ms max.
Release time
5 ms max.
Max. switching frequency
Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulaion resistance
1,000 mΩ min. (at 500 VDC)
Dielectric strength
2,000 VAC, 1mA 50/60Hz for 1 min between coil and contacts
750 VAC 1mA 50/60Hz for 1 min between contacts of same polarity
Vibration resistance
Destruction: 10 to 55Hz, 1.5mm double amplitude
Malfunction: 10 to 55Hz, 1.5mm double amplitude
Shock resistance
Destruction: 1,000m/s2(approx. 100G)
Malfunction: 100 m/s2(approx. 10G)
Endurance
Mechanical: 10,000,000 operations min.
Electrical: Approx. 100,000 operations
Ambient operating temperature
-40° to 85° (with no icing or condensation)
Ambient operating humidity
5% to 85%
Weight
Approx. 7.5g
Note. Values in the above table are the initial values.
2
G5LA
PCB Power Relay
■Engineering Data
●Durability (NO) (Average value)
●Ambient Temperature vs. Maximum
Coil Voltage
Note. The 120 VAC resistive load service life curve also
applies for 250 VAC resistive load.
Durability (x103 operations)
●Maximum switching capacity (NO)
G
5
L
A
Note. The maximum coil voltage refers to the maximum value in
a varying range of operating power voltage not a
continuous voltage.
3
G5LA
PCB Power Relay
■Dimensions
Note. All units are in millimeters unless otherwise indicated.
G5LA-1(-CF)
G5LA-14(-CF)
G5LA-1-E(-CF)
G5LA-14-E(-CF)
+0.2
0
1.1
1.3
+0.2
0
3.3
1.4
2
@0.5
0.4
12.2
1.2
4
15.8 MAX
(15.6)*
+0.2
0
12 ± 0.1
1.1
+0.2
0
2
1
3.3
0.4
1.3
1.4
1
Terminal
Arrangement/Internal
Connections (Bottom View)
1.8
15.8 MAX
(15.6)*
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
Unless specified
2-∅
4
5
12.2 ± 0.1
12
2-∅
19.8 MAX
(19.6)*
1
0.4
G5LA-1A(-CF)
G
5 G5LA-1A4(-CF)
L
A
@0.5
12.2
3
2 ± 0.1
1
19.8 MAX
(19.6)*
0.28
2
2
0.4
3-∅
12 ± 0.1
2-∅
0.28
Terminal
Arrangement/Internal
Connections (Bottom View)
1.8
15.8 MAX
(15.6)*
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
Unless specified
0.4
2 ± 0.1
1.2
12
15.8 MAX
(15.6)*
12.2 ± 0.1
5
3
G5LA
PCB Power Relay
■Approved Standards
●UL Recognized (File No. E41643)
Model
Contact form
Coil ratings
Contact ratings
10 A, 277 VAC, general use, 40°C
10 A, 30 VDC, resistive, 40°C
SPDT-NO (1a)
SPST-NO (1a)
G5LA
1/2 HP, 125-250VAC, 40°C
5 to 48 VDC
100,000
50,000
1,000
10 A, 277 VAC, general use, 85°C (-CF type only)
200 W Tungsten, 125 VAC, 40°C
10 A, 125 VAC, resistive, 40°C
10 A, 277 VAC, general use, 40°C (-E type only)
SPDT-NC (1b)
Number of test operations
10A, 24 VDC, resistive, 40°C (-E type only)
50,000
100,000
6,000
100,000
●CSA Certified (File No. LR31928)
Model
Contact form
Coil ratings
Contact ratings
10 A, 277 VAC, general use, 40°C
G5LA
SPDT-NO (1a)
SPST-NO (1a)
10 A, 24 VDC, resistive, 40°C
5 to 48 VDC
1/2 HP, 125-250VAC, 40°C
6,000
1,000
10 A, 277 VAC, general use, 85°C (-CF type only)
10 A, 125 VAC, resistive, 40°C
SPDT-NC (1b)
Number of test operations
6,000
●VDE Certified (Approval No. 40017051)
Model
Contact form
Coil ratings
Contact ratings
10 A, 250 VAC, resistive, 85°C (flux protection)
SPDT-NO (1a)
SPST-NO (1a)
G5LA
SPDT (1c)
10 A, 250 VAC, resistive, 85°C (fully sealed)
5, 9, 12, 24,
48 VDC
12 A, 250 VAC, resistive, 85°C
Number of test operations
50,000
10,000
5 A, 250 VAC, resistive, 85°C (flux protection)
50,000
5 A, 250 VAC, resistive, 85°C (fully sealed)
10,000
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. J184-E1-02
0113(1012)(O)
5
G
5
L
A