G3VM-354C/F MOS FET Relays Analog-switching MOS FET Relays with DPST-NC Contact. RoHS compliant Note: The actual product is marked differently from the image shown here. ■ Application Examples ■ Terminal Arrangement/Internal Connections • Communication equipment 8 7 6 5 • Security systems OMRON logo • FA systems Model name LOT.NO. 932 Pin 1 mark • Test & Measurement equipment 1 2 4 3 Note: The actual product is marked differently from the image shown here. ■ List of Models Package type Contact form Load voltage (peak value) * Terminals PCB Terminals DIP8 2b (DPST-NC) Minimum package quantity Model Number per tube Number per tape and reel G3VM-354C 350 V Surface-mounting Terminals G3VM-354F G3VM-354F (TR) 50 - - 1,500 * The AC peak and DC value are given for the load voltage. ■ Absolute Maximum Ratings (Ta = 25°C) Symbol IF Rating 50 Unit mA Repetitive peak LED forward current LED forward current reduction rate IFP ∆IF/°C 1 −0.5 A mA/°C LED reverse voltage Connection temperature VR TJ 5 125 V °C Load voltage (AC peak/DC) Continuous load current (AC peak/DC) VOFF IO 350 150 V mA ON current reduction rate Connection temperature ∆IO/°C TJ −1.5 125 mA/°C °C Ta ≥ 25°C Dielectric strength between I/O (See note 1.) Ambient operating temperature VI-O Ta 2500 −40 to +85 Vrms °C AC for 1 min With no icing or condensation Ambient storage temperature Soldering temperature Tstg - −55 to +125 260 °C °C With no icing or condensation 10 s Output Input Item LED forward current Measurement conditions 100 µs pulses, 100 pps Ta ≥ 25°C Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. ■ Electrical Characteristics (Ta = 25°C) Item LED forward voltage Symbol Minimum Typical Maximum VF 1.0 1.15 1.3 Unit V Measurement conditions IF = 10 mA IR - - 10 µA VR = 5 V Capacity between terminals CT - 30 - pF V = 0, f = 1 MHz Trigger LED forward current IFC - 1 3 mA IOFF = 10 µA Maximum resistance with output ON RON - 15 25 Ω IO = 150 mA Current leakage when the relay is open ILEAK - - 1.0 µA IF = 5 mA, VOFF = 350 V Capacity between terminals COFF - 85 - pF V = 0, f = 1 MHz Capacity between I/O terminals CI-O - 0.8 - pF f = 1 MHz, VS = 0 V, IF = 5 mA Insulation resistance between I/O terminals RI-O 1000 - - MΩ VI-O = 500 VDC, ROH ≤ 60% Turn-ON time Turn-OFF time tON tOFF - 0.1 1.0 1.0 3.0 ms ms IF = 5 mA, RL = 200 Ω, VDD = 20 V(See note 2.) Output Input Reverse current 1 Note: 2. Turn-ON and Turn-OFF Times IF 1(3) 8(6) 2(4) 7(5) RL IF VOUT 10% tON 90% tOFF VDD VOUT G3VM-354C/F MOS FET Relays ■ Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Load voltage (AC peak/DC) VDD - - 280 Unit V Operating LED forward current IF 5 - 25 mA Continuous load current (AC peak/DC) IO - - 150 mA Ambient operating temperature Ta −20 - 65 °C ■ Engineering Data LED forward current vs. Ambient temperature Continuous load current vs. Ambient temperature IO - Ta 80 60 40 IF - VF 300 LED forward current IF (mA) 100 Continuous load current IO (mA) LED forward current IF (mA) IF - Ta LED forward current vs. LED forward voltage 250 200 150 100 50 30 10 5 3 1 50 0 -20 0 20 40 60 80 100 0.3 0.1 0 -20 120 0 20 40 Ambient temperature Ta (°C) 60 80 100 On-state resistance vs. Ambient temperature On-state resistance RON (Ω) 100 0 1 2 IO = 150 mA t<1s 15 10 0 20 On-state voltage VON (V) 40 60 80 VDD = 20 V, RL = 200 Ω tOFF 500 300 tON 100 50 3 5 10 30 50 3 2 1 -20 0 IF = 5 mA 100 tOFF 800 600 60 80 100 1000 VOFF = 350 V IF = 5 mA 100 10 400 tON 200 0 -40 40 ILEAK - Ta VDD = 20 V, RL = 200 Ω 1000 20 Current leakage vs. Ambient temperature tON, tOFF - Ta 1200 30 1 4 Ambient temperature Ta (°C) Current leakage ILEAK (nA) Ta = 25°C Turn ON, Turn OFF time tON, tOFF (µs) tON, tOFF - IF 1.8 IOFF = 10 µA 0 -40 100 Turn ON, Turn OFF time vs. Ambient temperature 2000 1.6 5 Ambient temperature Ta (°C) Turn ON, Turn OFF time vs. LED forward current 1.4 IFC - Ta 20 0 -20 -200 0 1.2 Trigger LED forward current vs. Ambient temperature 5 -100 1000 1 RON - Ta Ta = 25°C -1 0.8 LED forward voltage VF (V) Trigger LED forward current IFC (mA) IO - VON 200 -2 0.6 120 Ambient temperature Ta (°C) Continuous load current vs. On-state voltage Continuous load current IO (mA) Ta = 25ºC 0.5 20 Turn ON, Turn OFF time t ON, tOFF (µs) 100 1 -20 LED forward current IF (mA) 0 20 40 60 80 100 Ambient temperature Ta (°C) 0 20 40 60 80 100 Ambient temperature Ta (°C) ■ Safety Precautions • Refer to "Common Precautions" for all G3VM models. 2 Appearance/Dimensions DIP8 type ■ Appearance DIP (Dual Inline Package) DIP8 OMRON logo Model name 932 Pin 1 mark LOT.NO. Note: The actual product is marked differently from the image shown here. ■ Dimensions (Unit: mm) PCB Terminals Surface-mounting Terminals PCB Dimensions (BOTTOM VIEW) Weight: 0.54 g Weight: 0.54 g Eight, 0.8-dia. holes 2.54 (0.61) 2.54 9.66±0.25 9.66±0.25 6.4±0.25 7.62±0.25 Actual Mounting Pad Dimensions 0.8±0.25 7.62±0.25 (Recommended Value, TOP VIEW) 3.65+0.15 –0.25 +0.1 0.25–0.05 2.5 min. 1.2±0.15 0.5±0.1 2.54±0.25 (0.61) (1.52) (1.52) 6.4±0.25 7.85 to 8.80 3.65+0.15 −0.25 4.0+0.25 −0.2 1.2±0.15 2.54±0.25 Note: The actual product is marked differently from the image shown here. 2.54 1.0 min. 1.0 min. 10.0 max. 8.3 to 8.8 1.3 1.5 • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. K250-E1-01 0413(0413)(O)