G3VM-354C/F

G3VM-354C/F
MOS FET Relays
Analog-switching MOS FET Relays with
DPST-NC Contact.
RoHS compliant
Note: The actual product is marked differently from the
image shown here.
■ Application Examples
■ Terminal Arrangement/Internal Connections
• Communication equipment
8
7
6
5
• Security systems
OMRON logo
• FA systems
Model
name
LOT.NO.
932
Pin 1 mark
• Test & Measurement equipment
1
2
4
3
Note: The actual product is marked differently from the image shown here.
■ List of Models
Package type Contact form
Load voltage
(peak value) *
Terminals
PCB Terminals
DIP8
2b
(DPST-NC)
Minimum package quantity
Model
Number per tube Number per tape and reel
G3VM-354C
350 V
Surface-mounting Terminals
G3VM-354F
G3VM-354F (TR)
50
-
-
1,500
* The AC peak and DC value are given for the load voltage.
■ Absolute Maximum Ratings (Ta = 25°C)
Symbol
IF
Rating
50
Unit
mA
Repetitive peak LED forward current
LED forward current reduction rate
IFP
∆IF/°C
1
−0.5
A
mA/°C
LED reverse voltage
Connection temperature
VR
TJ
5
125
V
°C
Load voltage (AC peak/DC)
Continuous load current (AC peak/DC)
VOFF
IO
350
150
V
mA
ON current reduction rate
Connection temperature
∆IO/°C
TJ
−1.5
125
mA/°C
°C
Ta ≥ 25°C
Dielectric strength between I/O (See note 1.)
Ambient operating temperature
VI-O
Ta
2500
−40 to +85
Vrms
°C
AC for 1 min
With no icing or condensation
Ambient storage temperature
Soldering temperature
Tstg
-
−55 to +125
260
°C
°C
With no icing or condensation
10 s
Output
Input
Item
LED forward current
Measurement conditions
100 µs pulses, 100 pps
Ta ≥ 25°C
Note: 1. The dielectric strength between the input and
output was checked by applying voltage
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
■ Electrical Characteristics (Ta = 25°C)
Item
LED forward voltage
Symbol Minimum Typical Maximum
VF
1.0
1.15
1.3
Unit
V
Measurement conditions
IF = 10 mA
IR
-
-
10
µA
VR = 5 V
Capacity between terminals
CT
-
30
-
pF
V = 0, f = 1 MHz
Trigger LED forward current
IFC
-
1
3
mA
IOFF = 10 µA
Maximum resistance with output ON
RON
-
15
25
Ω
IO = 150 mA
Current leakage when the relay is open
ILEAK
-
-
1.0
µA
IF = 5 mA, VOFF = 350 V
Capacity between terminals
COFF
-
85
-
pF
V = 0, f = 1 MHz
Capacity between I/O terminals
CI-O
-
0.8
-
pF
f = 1 MHz, VS = 0 V, IF = 5 mA
Insulation resistance between I/O terminals
RI-O
1000
-
-
MΩ
VI-O = 500 VDC, ROH ≤ 60%
Turn-ON time
Turn-OFF time
tON
tOFF
-
0.1
1.0
1.0
3.0
ms
ms
IF = 5 mA, RL = 200 Ω,
VDD = 20 V(See note 2.)
Output
Input
Reverse current
1
Note: 2. Turn-ON and Turn-OFF Times
IF 1(3)
8(6)
2(4)
7(5)
RL
IF
VOUT
10%
tON
90%
tOFF
VDD
VOUT
G3VM-354C/F
MOS FET Relays
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
Load voltage (AC peak/DC)
VDD
-
-
280
Unit
V
Operating LED forward current
IF
5
-
25
mA
Continuous load current (AC peak/DC)
IO
-
-
150
mA
Ambient operating temperature
Ta
−20
-
65
°C
■ Engineering Data
LED forward current vs. Ambient
temperature
Continuous load current vs. Ambient
temperature
IO - Ta
80
60
40
IF - VF
300
LED forward current IF (mA)
100
Continuous load current IO (mA)
LED forward current IF (mA)
IF - Ta
LED forward current vs. LED forward
voltage
250
200
150
100
50
30
10
5
3
1
50
0
-20
0
20
40
60
80
100
0.3
0.1
0
-20
120
0
20
40
Ambient temperature Ta (°C)
60
80
100
On-state resistance vs. Ambient
temperature
On-state resistance RON (Ω)
100
0
1
2
IO = 150 mA
t<1s
15
10
0
20
On-state voltage VON (V)
40
60
80
VDD = 20 V, RL = 200 Ω
tOFF
500
300
tON
100
50
3
5
10
30
50
3
2
1
-20
0
IF = 5 mA
100
tOFF
800
600
60
80
100
1000
VOFF = 350 V
IF = 5 mA
100
10
400
tON
200
0
-40
40
ILEAK - Ta
VDD = 20 V, RL = 200 Ω
1000
20
Current leakage vs. Ambient
temperature
tON, tOFF - Ta
1200
30
1
4
Ambient temperature Ta (°C)
Current leakage ILEAK (nA)
Ta = 25°C
Turn ON, Turn OFF time tON, tOFF (µs)
tON, tOFF - IF
1.8
IOFF = 10 µA
0
-40
100
Turn ON, Turn OFF time vs. Ambient
temperature
2000
1.6
5
Ambient temperature Ta (°C)
Turn ON, Turn OFF time vs. LED
forward current
1.4
IFC - Ta
20
0
-20
-200
0
1.2
Trigger LED forward current vs.
Ambient temperature
5
-100
1000
1
RON - Ta
Ta = 25°C
-1
0.8
LED forward voltage VF (V)
Trigger LED forward current IFC (mA)
IO - VON
200
-2
0.6
120
Ambient temperature Ta (°C)
Continuous load current vs. On-state
voltage
Continuous load current IO (mA)
Ta = 25ºC
0.5
20
Turn ON, Turn OFF time t ON, tOFF (µs)
100
1
-20
LED forward current IF (mA)
0
20
40
60
80
100
Ambient temperature Ta (°C)
0
20
40
60
80
100
Ambient temperature Ta (°C)
■ Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
DIP8 type
■ Appearance
DIP (Dual Inline Package)
DIP8
OMRON logo
Model name
932
Pin 1 mark
LOT.NO.
Note: The actual product is marked differently from the image shown here.
■ Dimensions
(Unit: mm)
PCB Terminals
Surface-mounting Terminals PCB Dimensions (BOTTOM VIEW)
Weight: 0.54 g
Weight: 0.54 g
Eight, 0.8-dia. holes
2.54
(0.61)
2.54
9.66±0.25
9.66±0.25
6.4±0.25
7.62±0.25
Actual Mounting Pad Dimensions
0.8±0.25
7.62±0.25
(Recommended Value, TOP VIEW)
3.65+0.15
–0.25
+0.1
0.25–0.05
2.5 min.
1.2±0.15
0.5±0.1
2.54±0.25
(0.61)
(1.52)
(1.52)
6.4±0.25
7.85 to 8.80
3.65+0.15
−0.25
4.0+0.25
−0.2
1.2±0.15
2.54±0.25
Note: The actual product is marked differently from the
image shown here.
2.54
1.0 min.
1.0 min.
10.0 max.
8.3 to 8.8
1.3
1.5
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K250-E1-01
0413(0413)(O)