G3VM-401G1

G3VM-401G1
MOS FET Relays
Ultrasensitive MOS FET Relays in 400-V Load series
for electric power saving.
• Continuous load current of 100 mA.
RoHS compliant
Note: The actual product is marked differently from the
image shown here.
■ Application Examples
■ Terminal Arrangement/Internal Connections
4
• Communication equipment
3
Mold pin
mark *
• Test & Measurement equipment
OMRON logo
• Security equipment
-401G1
932
Pin 1 mark
• Amusement equipment
1
• Industrial equipment
Model name
LOT.No.
2
Note: The actual product is marked differently from the image shown here.
* The indentation in the corner diagonally opposite from the pin 1 mark is from
a pin on the mold.
• Various battery-driven devices
■ List of Models
Package type
Contact form
SOP4
1a
(SPST-NO)
Load voltage
(peak value) *
Terminals
Surface-mounting Terminals
400 V
Model
G3VM-401G1
G3VM-401G1 (TR)
Minimum package quantity
Number per tube Number per tape and reel
100
-
-
2,500
* The AC peak and DC value are given for the load voltage.
Input
■ Absolute Maximum Ratings (Ta = 25°C)
Item
LED forward current
Repetitive peak LED forward current
Output
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Continuous load current (AC peak/DC)
ON current reduction rate
Pulse ON current
Connection temperature
Dielectric strength between I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
Symbol
IF
IFP
Rating
30
1
Unit
mA
A
ΔIF/°C
VR
TJ
VOFF
IO
ΔIO/°C
IOP
TJ
VI-O
Ta
Tstg
-
−0.3
5
125
400
100
−1.0
0.3
125
1500
−40 to +85
−55 to +125
260
mA/°C
V
°C
V
mA
mA/°C
A
°C
Vrms
°C
°C
°C
Measurement conditions
100 μs pulses, 100 pps
Ta ≥ 25°C
Ta ≥ 25°C
t = 100 ms, Duty = 1/10
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Note: 1. The dielectric strength between the input and
output was checked by applying voltage
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
■ Electrical Characteristics (Ta = 25°C)
Output
Input
Item
Symbol Minimum Typical Maximum
LED forward voltage
VF
1.1
1.27
1.4
Reverse current
IR
10
Capacity between terminals
CT
30
Trigger LED forward current
IFT
0.2
Maximum resistance with output ON
RON
18
35
Current leakage when the relay is open
ILEAK
1
1000
Capacity between terminals
Coff
70
Capacity between I/O terminals
CI-O
0.8
Insulation resistance between I/O terminals
RI-O
1000
Turn-ON time
tON
2
10
Turn-OFF time
tOFF
1
5
1
Unit
V
μA
pF
mA
Ω
nA
pF
pF
MΩ
ms
ms
Measurement conditions
IF = 10 mA
Note: 2. Turn-ON and Turn-OFF Times
VR = 5 V
IF 1
4 RL
VDD
V = 0, f = 1 MHz
VOUT
2
3
IO = 100 mA
IF = 0.5mA, IO = 100 mA, t < 1 s
VOFF = 400 V
V = 0, f = 1 MHz
IF
f = 1 MHz, VS = 0 V
VI-O = 500 VDC, ROH ≤ 60 %
90%
VOUT
10%
IF = 0.5 mA, RL = 200 Ω,
t
ON
t OFF
VDD = 20 V (See note 2.)
G3VM-401G1
MOS FET Relays
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
Unit
Load voltage (AC peak/DC)
Operating LED forward current
Continuous load current (AC peak/DC)
Ambient operating temperature
VDD
IF
IO
Ta
−20
0.5
-
320
25
80
65
V
mA
mA
°C
■ Engineering Data
Continuous load current vs. Ambient temperature LED forward current vs. LED forward voltage
Continuous load current IO (mA)
LED forward current IF (mA)
IF - Ta
50
40
30
20
10
IO - Ta
150
100
50
100
Ta = 25 °C
10
1
0
0
-40
-20
0
20
40
60
80
0.1
-40
100
-20
0
Ambient temperature Ta (°C)
20
40
60
80
100
IO - VON
80
40
0
-40
0
1
IO = 100 mA
IF = 0.5 mA, t < 1 s
40
30
20
0.2
I O = 100 mA
t<1s
0.1
0
-40
2
1.6
Trigger LED forward current vs. Ambient temperature
0
-120
1.4
IFT - Ta
50
10
-80
-1
1.2
LED forward voltage VF (V)
Trigger LED forward current IFT (mA)
Ta = 25 °C
I F = 1 mA, t < 1 s
-2
1
RON - Ta
On-state resistance RON (Ω)
120
0.8
Ambient temperature Ta (°C)
Continuous load current vs. On-state voltage On-state resistance vs. Ambient temperature
Continuous load current IO (mA)
IF - VF
LED forward current IF (mA)
LED forward current vs. Ambient temperature
-20
0
On-state voltage VON (V)
20
40
60
80
-40
100
-20
0
Ambient temperature Ta (°C)
20
40
60
80
100
Ambient temperature Ta (°C)
t OFF
1
0.1
t ON
VDD = 20 V
RL = 200 Ω
Ta = 25 °C
0.01
0.1
1
10
100
tON, tOFF - Ta
Current leakage ILEAK (nA)
tON, tOFF - IF
10
Turn ON, Turn OFF time tON, tOFF (ms)
Turn ON, Turn OFF time tON, tOFF (ms)
Turn ON, Turn OFF time vs. LED forward current Turn ON, Turn OFF time vs. Ambient temperature Current leakage vs. Ambient temperature
10
t ON
1
ILEAK - Ta
100
VOFF = 400 V
10
1
0.1
VDD = 20 V
R L= 200 Ω
IF = 0.5 mA
t OFF
0.1
0.01
-40
-20
LED forward current IF (mA)
0
20
40
60
80
100
Ambient temperature Ta (°C)
-40
-20
0
20
40
60
80
100
Ambient temperature Ta (°C)
Current leakage vs. Load voltage
ILEAK - VOFF
Current leakage ILEAK (nA)
1
Ta = 25 °C
0.8
0.6
0.4
0.2
0
0
100
200
300
400
Load voltage VOFF(v)
■ Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
SOP4 type
■ Appearance
SOP (Small Outline Package)
SOP4
Mold pin mark *
OMRON logo
Pin 1 mark
-401G1
932
Model name
LOT.No.
Note: The actual product is marked differently from the image shown here.
* The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold.
■ Dimensions
(Unit: mm)
Surface-mounting Terminals
Actual Mounting Pad
Dimensions
Weight: 0.1 g
4.4±0.25
3.9±0.2
(Recommended Value, TOP VIEW)
2.1 max.
6 to 6.3
0.15
0.4±0.1
0.1±0.1
1.2
0.6±0.3
7.0±0.4
2.54±0.25
Note: The actual product is marked differently from the image shown here.
0.8
2.54
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K258-E1-02