G3VM-401G1 MOS FET Relays Ultrasensitive MOS FET Relays in 400-V Load series for electric power saving. • Continuous load current of 100 mA. RoHS compliant Note: The actual product is marked differently from the image shown here. ■ Application Examples ■ Terminal Arrangement/Internal Connections 4 • Communication equipment 3 Mold pin mark * • Test & Measurement equipment OMRON logo • Security equipment -401G1 932 Pin 1 mark • Amusement equipment 1 • Industrial equipment Model name LOT.No. 2 Note: The actual product is marked differently from the image shown here. * The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold. • Various battery-driven devices ■ List of Models Package type Contact form SOP4 1a (SPST-NO) Load voltage (peak value) * Terminals Surface-mounting Terminals 400 V Model G3VM-401G1 G3VM-401G1 (TR) Minimum package quantity Number per tube Number per tape and reel 100 - - 2,500 * The AC peak and DC value are given for the load voltage. Input ■ Absolute Maximum Ratings (Ta = 25°C) Item LED forward current Repetitive peak LED forward current Output LED forward current reduction rate LED reverse voltage Connection temperature Load voltage (AC peak/DC) Continuous load current (AC peak/DC) ON current reduction rate Pulse ON current Connection temperature Dielectric strength between I/O (See note 1.) Ambient operating temperature Ambient storage temperature Soldering temperature Symbol IF IFP Rating 30 1 Unit mA A ΔIF/°C VR TJ VOFF IO ΔIO/°C IOP TJ VI-O Ta Tstg - −0.3 5 125 400 100 −1.0 0.3 125 1500 −40 to +85 −55 to +125 260 mA/°C V °C V mA mA/°C A °C Vrms °C °C °C Measurement conditions 100 μs pulses, 100 pps Ta ≥ 25°C Ta ≥ 25°C t = 100 ms, Duty = 1/10 AC for 1 min With no icing or condensation With no icing or condensation 10 s Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. ■ Electrical Characteristics (Ta = 25°C) Output Input Item Symbol Minimum Typical Maximum LED forward voltage VF 1.1 1.27 1.4 Reverse current IR 10 Capacity between terminals CT 30 Trigger LED forward current IFT 0.2 Maximum resistance with output ON RON 18 35 Current leakage when the relay is open ILEAK 1 1000 Capacity between terminals Coff 70 Capacity between I/O terminals CI-O 0.8 Insulation resistance between I/O terminals RI-O 1000 Turn-ON time tON 2 10 Turn-OFF time tOFF 1 5 1 Unit V μA pF mA Ω nA pF pF MΩ ms ms Measurement conditions IF = 10 mA Note: 2. Turn-ON and Turn-OFF Times VR = 5 V IF 1 4 RL VDD V = 0, f = 1 MHz VOUT 2 3 IO = 100 mA IF = 0.5mA, IO = 100 mA, t < 1 s VOFF = 400 V V = 0, f = 1 MHz IF f = 1 MHz, VS = 0 V VI-O = 500 VDC, ROH ≤ 60 % 90% VOUT 10% IF = 0.5 mA, RL = 200 Ω, t ON t OFF VDD = 20 V (See note 2.) G3VM-401G1 MOS FET Relays ■ Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Unit Load voltage (AC peak/DC) Operating LED forward current Continuous load current (AC peak/DC) Ambient operating temperature VDD IF IO Ta −20 0.5 - 320 25 80 65 V mA mA °C ■ Engineering Data Continuous load current vs. Ambient temperature LED forward current vs. LED forward voltage Continuous load current IO (mA) LED forward current IF (mA) IF - Ta 50 40 30 20 10 IO - Ta 150 100 50 100 Ta = 25 °C 10 1 0 0 -40 -20 0 20 40 60 80 0.1 -40 100 -20 0 Ambient temperature Ta (°C) 20 40 60 80 100 IO - VON 80 40 0 -40 0 1 IO = 100 mA IF = 0.5 mA, t < 1 s 40 30 20 0.2 I O = 100 mA t<1s 0.1 0 -40 2 1.6 Trigger LED forward current vs. Ambient temperature 0 -120 1.4 IFT - Ta 50 10 -80 -1 1.2 LED forward voltage VF (V) Trigger LED forward current IFT (mA) Ta = 25 °C I F = 1 mA, t < 1 s -2 1 RON - Ta On-state resistance RON (Ω) 120 0.8 Ambient temperature Ta (°C) Continuous load current vs. On-state voltage On-state resistance vs. Ambient temperature Continuous load current IO (mA) IF - VF LED forward current IF (mA) LED forward current vs. Ambient temperature -20 0 On-state voltage VON (V) 20 40 60 80 -40 100 -20 0 Ambient temperature Ta (°C) 20 40 60 80 100 Ambient temperature Ta (°C) t OFF 1 0.1 t ON VDD = 20 V RL = 200 Ω Ta = 25 °C 0.01 0.1 1 10 100 tON, tOFF - Ta Current leakage ILEAK (nA) tON, tOFF - IF 10 Turn ON, Turn OFF time tON, tOFF (ms) Turn ON, Turn OFF time tON, tOFF (ms) Turn ON, Turn OFF time vs. LED forward current Turn ON, Turn OFF time vs. Ambient temperature Current leakage vs. Ambient temperature 10 t ON 1 ILEAK - Ta 100 VOFF = 400 V 10 1 0.1 VDD = 20 V R L= 200 Ω IF = 0.5 mA t OFF 0.1 0.01 -40 -20 LED forward current IF (mA) 0 20 40 60 80 100 Ambient temperature Ta (°C) -40 -20 0 20 40 60 80 100 Ambient temperature Ta (°C) Current leakage vs. Load voltage ILEAK - VOFF Current leakage ILEAK (nA) 1 Ta = 25 °C 0.8 0.6 0.4 0.2 0 0 100 200 300 400 Load voltage VOFF(v) ■ Safety Precautions • Refer to "Common Precautions" for all G3VM models. 2 Appearance/Dimensions SOP4 type ■ Appearance SOP (Small Outline Package) SOP4 Mold pin mark * OMRON logo Pin 1 mark -401G1 932 Model name LOT.No. Note: The actual product is marked differently from the image shown here. * The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold. ■ Dimensions (Unit: mm) Surface-mounting Terminals Actual Mounting Pad Dimensions Weight: 0.1 g 4.4±0.25 3.9±0.2 (Recommended Value, TOP VIEW) 2.1 max. 6 to 6.3 0.15 0.4±0.1 0.1±0.1 1.2 0.6±0.3 7.0±0.4 2.54±0.25 Note: The actual product is marked differently from the image shown here. 0.8 2.54 • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. K258-E1-02 0613(0613)(O)