G3VM-61G2

G3VM-61G2
MOS FET Relays
Ultrasensitive MOS FET Relays in 60-V Load series
for electric power saving.
• Trigger LED forward current of 1 mA (maximum) facilitates power saving
designs and prolonged battery life.
• Continuous load current of 400 mA.
RoHS compliant
Note: The actual product is marked differently from the
image shown here.
■ Application Examples
■ Terminal Arrangement/Internal
Connections
• Communication equipment
4
• Test & Measurement equipment
3
Mold pin
mark *
• Security equipment
OMRON logo
• Amusement equipment
932
Pin 1 mark
• Industrial equipment
1
• Various battery-driven devices
Model name
LOT.No.
2
Note: The actual product is marked differently from the image shown here.
* The indentation in the corner diagonally opposite from the pin 1 mark is from
a pin on the mold.
■ List of Models
Package type Contact form
SOP4
1a
(SPST-NO)
Load voltage
(peak value) *
Terminals
Surface-mounting Terminals
60 V
Model
G3VM-61G2
G3VM-61G2 (TR)
Minimum package quantity
Number per tube Number per tape and reel
100
-
-
2,500
* The AC peak and DC value are given for the load voltage.
■ Absolute Maximum Ratings (Ta = 25°C)
Output
Input
Item
LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Continuous load current (AC peak/DC)
ON current reduction rate
Connection temperature
Dielectric strength between
I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
Symbol
IF
∆IF/°C
VR
TJ
VOFF
IO
∆IO/°C
TJ
Rating
50
−0.5
5
125
60
400
−4.0
125
Unit
mA
mA/°C
V
°C
V
mA
mA/°C
°C
VI-O
1500
Vrms
Ta
Tstg
-
−40 to +85
−55 to +125
260
°C
°C
°C
Measurement conditions
Ta ≥ 25°C
Ta ≥ 25°C
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Note: 1. The dielectric strength between the input and
output was checked by applying voltage
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
■ Electrical Characteristics (Ta = 25°C)
Output
Input
Item
Symbol Minimum Typical Maximum
LED forward voltage
VF
1.0
1.15
1.3
Reverse current
IR
10
Capacity between terminals
CT
30
Trigger LED forward current
IFT
0.4
1
Maximum resistance with output ON
RON
1
2
Current leakage when the relay is open
ILEAK
1
1000
Capacity between terminals
Coff
130
Capacity between I/O terminals
CI-O
0.8
Insulation resistance between I/O terminals
RI-O
1000
Turn-ON time
tON
3
8
Turn-OFF time
tOFF
1
3
1
Unit
V
µA
pF
mA
Ω
nA
pF
pF
MΩ
ms
ms
Measurement conditions
IF = 10 mA
Note: 2. Turn-ON and Turn-OFF Times
VR = 5 V
IF 1
4 RL
VDD
V = 0, f = 1 MHz
VOUT
2
3
IO = 400 mA
IF = 2 mA, IO = 400 mA
VOFF = 60 V
V = 0, f = 1 MHz
IF
f = 1 MHz, VS = 0 V
VI-O = 500 VDC, ROH ≤ 60 %
90%
VOUT
10%
IF = 2 mA, RL = 200 Ω,
t ON
t OFF
VDD = 20 V (See note 2.)
G3VM-61G2
MOS FET Relays
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
Unit
Load voltage (AC peak/DC)
Operating LED forward current
Continuous load current (AC peak/DC)
Ambient operating temperature
VDD
IF
IO
Ta
−20
2
-
48
25
320
65
V
mA
mA
°C
■ Engineering Data
Continuous load current vs. Ambient
temperature
50
40
30
20
IO - Ta
500
400
300
200
0
Ta = 25 °C
10
1
0.1
0.8
0
20
40
60
80
100
-40
0
-20
20
Ambient temperature Ta (°C)
Continuous load current vs. On-state
voltage
200
100
0
-100
-200
-300
0
0.8
0.6
0.4
IO = 400 mA
IF = 2 mA
t < 1s
0.2
-40
0.4
0
-20
20
On-state voltage VON (V)
Turn ON, Turn OFF time vs. LED
forward current
Turn ON, Turn OFF time tON, tOFF (ms)
10
tOFF
1
tON
0.1
1
10
100
1.4
60
80
0.7
0.6
0.5
0.4
0.3
0.2
IO = 400 mA
0.1
t < 1s
100
tON, tOFF - Ta
VDD = 20 V
RL = 200 Ω
IF = 2 mA
1.3
0.8
-40
-20
0
Ambient temperature Ta (°C)
10
1.2
0
Turn ON, Turn OFF time vs. Ambient
temperature
tON, tOFF - IF
VDD = 20 V
RL = 200 Ω
Ta = 25 °C
40
1.1
LED forward voltage VF (V)
0
0.1
1.0
IFT - Ta
1.0
-400
-0.2
0.9
Trigger LED forward current vs.
Ambient temperature
1.2
0.2
0.01
100
On-state resistance vs. Ambient
temperature
On-state resistance RON (Ω)
300
100
80
RON - Ta
Ta = 25 °C
IF = 2 mA
-500
-0.4
60
Ambient temperature Ta (°C)
IO - VON
500
400
40
Trigger LED forward current IFT (mA)
0
-20
tON
1
tOFF
20
40
60
80
100
Ambient temperature Ta (°C)
Current leakage vs. Ambient
temperature
Current leakage ILEAK (nA)
-40
Continuous load current IO (mA)
IF - VF
100
100
10
Turn ON, Turn OFF time tON, tOFF (ms)
LED forward current vs. LED forward
voltage
LED forward current IF (mA)
IF - Ta
60
Continuous load current IO (mA)
LED forward current IF (mA)
LED forward current vs. Ambient
temperature
ILEAK - Ta
100
VOFF = 60 V
10
1
0.1
0.01
0.1
-40
-20
0
LED forward current IF (mA)
20
40
60
80
100
Ambient temperature Ta (°C)
0.001
-40
-20
0
20
40
60
80
100
Ambient temperature Ta (°C)
■ Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
SOP4 type
■ Appearance
SOP (Small Outline Package)
SOP4
Mold pin mark *
OMRON logo
Pin 1 mark
932
Model name
LOT.No.
Note: The actual product is marked differently from the image shown here.
* The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold.
■ Dimensions
(Unit: mm)
Surface-mounting Terminals
Actual Mounting Pad
Dimensions
Weight: 0.1 g
4.4±0.25
3.9±0.2
(Recommended Value, TOP VIEW)
2.1 max.
6 to 6.3
0.15
0.4±0.1
0.1±0.1
1.2
0.6±0.3
7.0±0.4
2.54±0.25
Note: The actual product is marked differently from the image shown here.
0.8
2.54
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K153-E1-01
0412(0412)(O)