G3VM-201G MOS FET Relays MOS FET Relays Designed for Switching Minute Signals and Analog Signals. • Leakage current of 1 nA max. when output relay is open. RoHS compliant Note: The actual product is marked differently from the image shown here. ■ Application Examples ■ Terminal Arrangement/Internal Connections 4 • Semiconductor test equipment 3 Mold pin mark * • Test & Measurement equipment OMRON logo • Communication equipment 932 Pin 1 mark • Data loggers 1 Model name LOT.No. 2 Note: The actual product is marked differently from the image shown here. * The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold. ■ List of Models Package type Contact form SOP4 1a (SPST-NO) Load voltage (peak value) * Terminals Surface-mounting Terminals 200 V Model G3VM-201G G3VM-201G (TR) Minimum package quantity Number per tube Number per tape and reel 100 - - 2,500 * The AC peak and DC value are given for the load voltage. ■ Absolute Maximum Ratings (Ta = 25°C) Output Input Item LED forward current Repetitive peak LED forward current LED forward current reduction rate LED reverse voltage Connection temperature Load voltage(AC peak/DC) Continuous load current(AC peak/DC) ON current reduction rate Connection temperature Dielectric strength between I/O (See note 1.) Ambient operating temperature Ambient storage temperature Soldering temperature Symbol IF IFP ∆IF/°C VR TJ VOFF IO ∆IO/°C TJ Rating 50 1 −0.5 5 125 200 50 −0.5 125 Unit mA A mA/°C V °C V mA mA/°C °C VI-O 1500 Vrms Ta Tstg - −40 to +85 −55 to +125 260 °C °C °C Measurement conditions 100 µs pulses, 100 pps Ta ≥ 25°C Ta ≥ 25°C AC for 1 min With no icing or condensation With no icing or condensation 10 s Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. ■ Electrical Characteristics (Ta = 25°C) Output Input Item Symbol Minimum Typical Maximum LED forward voltage VF 1.0 1.15 1.3 Reverse current IR 10 Capacity between terminals CT 30 Trigger LED forward current IFT 1 3 Maximum resistance with output ON RON 40 50 Current leakage when the relay is open ILEAK 1 Capacity between terminals COFF 15 20 Capacity between I/O terminals CI-O 0.8 Insulation resistance between I/O terminals RI-O 1000 Turn-ON time tON 0.5 Turn-OFF time tOFF 0.2 1 Unit V µA pF mA Ω nA pF pF MΩ ms ms Measurement conditions IF = 10 mA Note: 2. Turn-ON and Turn-OFF Times VR = 5 V IF 1 4 RL VDD V = 0, f = 1 MHz VOUT 2 3 IO = 50 mA IF = 5 mA, IO = 50 mA VOFF = 160 V, Ta = 25 °C V = 0, f = 100 MHz, t < 10 s IF f = 1 MHz, VS = 0 V VI-O = 500 VDC, ROH ≤ 60 % 90% VOUT 10% IF = 5 mA, RL = 200 Ω, t ON t OFF VDD = 20 V (See note 2.) G3VM-201G MOS FET Relays ■ Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Unit Load voltage (AC peak/DC) Operating LED forward current Continuous load current (AC peak/DC) Ambient operating temperature VDD IF IO Ta 5 25 7.5 - 160 15 40 60 V mA mA °C ■ Engineering Data LED forward current vs. Ambient temperature Continuous load current vs. Ambient temperature IO - Ta 40 20 60 40 100 Ta = 25°C 10 20 1 0 0 -20 0 20 40 60 80 0.1 -40 100 -20 0 20 Ambient temperature Ta (°C) Continuous load current vs. On-state voltage 60 80 0.6 100 On-state resistance vs. Ambient temperature IO - VON 0.8 1 On-state resistance RON (Ω) Ta = 25°C IF = 5 mA 30 20 10 0 -10 1.2 1.6 1.8 Trigger LED forward current vs. Ambient temperature IFT - Ta 40 IO = 50 mA IF = 5 mA t < 1s 30 1.4 LED forward voltage VF (V) RON - Ta 50 40 40 Ambient temperature Ta (°C) Trigger LED forward current IFT (mA) -40 Continuous load current IO (mA) IF - VF LED forward current IF (mA) 60 Continuous load current IO (mA) LED forward current IF (mA) IF - Ta LED forward current vs. LED forward voltage 20 -20 10 -30 1.5 IO = 50 mA t < 1s 1.0 0.5 -40 0 -1.5 -1.0 -0.5 0 0.5 1.0 1.5 0 -40 2.0 -20 0 20 On-state voltage VON (V) Turn ON, Turn OFF time vs. LED forward current 80 Turn ON, Turn OFF time tON, tOFF (µs) Ta = 25°C VDD = 10 V RL = 200 Ω t < 1s tOFF 10 tON -20 0 10 100 20 40 60 80 100 Ambient temperature Ta (°C) Current leakage vs. Ambient temperature ILEAK - Ta 1000 VDD = 10 V RL = 200 Ω IF = 5 mA tON 100 10 VOFF = 200 V 1 0.1 tOFF 10 1 1 -40 100 tON, tOFF - Ta tON, tOFF - IF Turn ON, Turn OFF time tON, tOFF (µs) 60 Turn ON, Turn OFF time vs. Ambient temperature 1000 100 40 Ambient temperature Ta (°C) Current leakage ILEAK (nA) -50 -2.0 0.01 -40 -20 0 LED forward current IF (mA) 20 40 60 80 100 Ambient temperature Ta (°C) 20 40 60 80 100 Ambient temperature Ta (°C) ■ Safety Precautions • Refer to "Common Precautions" for all G3VM models. 2 Appearance/Dimensions SOP4 type ■ Appearance SOP (Small Outline Package) SOP4 Mold pin mark * OMRON logo Pin 1 mark 932 Model name LOT.No. Note: The actual product is marked differently from the image shown here. * The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold. ■ Dimensions (Unit: mm) Surface-mounting Terminals Actual Mounting Pad Dimensions Weight: 0.1 g 4.4±0.25 3.9±0.2 (Recommended Value, TOP VIEW) 2.1 max. 6 to 6.3 0.15 0.4±0.1 0.1±0.1 1.2 0.6±0.3 7.0±0.4 2.54±0.25 Note: The actual product is marked differently from the image shown here. 0.8 2.54 • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. K159-E1-01 0412(0412)(O)