G3VM-101HR

G3VM-101HR
MOS FET Relays
Higher power, 1.4-A switching with a 100-V load voltage,
SOP package. Low 100-mΩ ON Resistance.
• Continuous load current of 1.4 A. (Connection C: 2.8 A)
RoHS compliant
Note: The actual product is marked differently from the
image shown here.
■ Application Examples
■ Terminal Arrangement/Internal Connections
6
5
4
• Communication equipment
• Test & Measurement equipment
OMRON logo
• Data loggers
Pin 1 mark
• Industrial equipment
1
101HR
Model name
932
LOT.No.
3
2
Note: The actual product is marked differently from the image shown here.
■ List of Models
Package type Contact form
Terminals
Load voltage
(peak value) *
Model
100 V
G3VM-101HR
G3VM-101HR (TR)
1a
Surface-mounting Terminals
(SPST-NO)
* The AC peak and DC value are given for the load voltage.
SOP6
Minimum package quantity
Number per tube Number per tape and reel
75
2,500
■ Absolute Maximum Ratings (Ta = 25°C)
Output
Input
Item
LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Connection A
Continuous
Connection B
load current
Connection C
Connection A
ON current
reduction
Connection B
rate
Connection C
Pulse ON current
Connection temperature
Dielectric strength between
I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
Symbol
IF
∆IF/°C
VR
TJ
VOFF
Unit
mA
mA/°C
V
°C
V
Iop
TJ
Rating
30
−0.3
5
125
100
1.4
1.4
2.8
−18.7
−18.7
−37.3
4
125
VI-O
1500
Vrms
Ta
Tstg
-
−40 to +85
−55 to +125
260
°C
°C
°C
IO
∆IO/°C
A
mA/°C
Measurement conditions
Ta ≥ 25°C
Note: 1. The dielectric strength between the input and output was
checked by applying voltage between all pins as a group on
the LED side and all pins as a group on the light-receiving side.
Connection Diagram
Connection A: AC peak/DC
Connection B and C: DC
Connection A
Ta ≥ 50°C
Connection B
A
°C
t = 100 ms
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Connection C
1
6
2
5
3
4
1
6
2
5
3
4
1
6
2
5
3
4
■ Electrical Characteristics (Ta = 25°C)
Output
Input
Item
Symbol Minimum Typical Maximum
LED forward voltage
VF
1.18
1.33
1.48
Reverse current
IR
10
Capacity between terminals
CT
70
Trigger LED forward current
IFT
0.4
3
Connection A
0.1
0.2
Maximum
resistance
Connection B
RON
0.05
0.1
with output ON Connection C
0.025
Current leakage when the relay is open
ILEAK
10
Capacity between terminals
Coff
1000
Capacity between I/O terminals
CI-O
0.8
Insulation resistance between I/O terminals
RI-O
1000
Turn-ON time
tON
1.0
5.0
Turn-OFF time
tOFF
0.15
1.0
1
Unit
V
µA
pF
mA
Ω
Ω
Ω
nA
pF
pF
MΩ
ms
ms
Measurement conditions
IF = 10 mA
VR = 5 V
V = 0, f = 1 MHz
Note: 2. Turn-ON and Turn-OFF Times
IO = 100 mA
IF 1
6 RL
VDD
IF = 5 mA, IO = 1.4 A, t < 1 s
VOUT
2
4
IF = 5 mA, IO = 1.4 A, t < 1 s
IF = 5 mA, IO = 2.8 A, t < 1 s
VOFF = 100 V
V = 0, f = 1 MHz
IF
f = 1 MHz, VS = 0 V
VI-O = 500 VDC, ROH ≤ 60 %
90%
VOUT
10%
IF = 5 mA, RL = 200 Ω,
t ON
t OFF
VDD = 20 V (See note 2.)
Load
or AC
DC
Load
DC
Load
DC
G3VM-101HR
MOS FET Relays
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
Load voltage (AC peak/DC)
VDD
-
-
100
Unit
V
Operating LED forward current
IF
5
7.5
20
mA
Continuous load current (AC peak/DC)
IO
-
-
1.1
A
Ambient operating temperature
Ta
−20
-
65
°C
■ Engineering Data
Continuous load current vs. Ambient temperature
Continuous load current IO (A)
LED forward current IF (mA)
IF - Ta
50
40
30
20
IO - Ta
5
4
3
Connection C
2
-40
-20
0
20
40
60
80
100
Ta = 25°C
10
Connection A and B
0
-40
0
IF - VF
100
1
1
10
LED forward current vs. LED forward voltage
LED forward current IF (mA)
LED forward current vs. Ambient temperature
-20
20
0
Ambient temperature Ta (°C)
40
60
0.1
0.6
100
80
0.8
1.0
1.2
Ambient temperature Ta (°C)
1.4
1.6
1.8
LED forward voltage VF (V)
Continuous load current vs. On-state voltage On-state resistance vs. Ambient temperature Trigger LED forward current vs. Ambient temperature
IF = 5 mA,
Connection A
1
Ta = 25°C
0.5
0
-0.5
IFT - Ta
Trigger LED forward current IFT (mA)
RON - Ta
On-state resistance RON (mΩ)
Continuous load current IO (A)
IO - VON
1.5
200
Io = 1.4 A
IF = 5 mA,
t < 1s, Connection A
150
100
50
2.0
IO = 100 mA
t < 1s
1.5
1.0
0.5
-1
-1.5
-0.15
-0.1
-0.05
0
0.05
0.1
0
-40
0.15
-20
0
On-state voltage VON (V)
20
40
60
80
Turn ON, Turn OFF time vs. LED forward current Turn ON, Turn OFF time vs. Ambient temperature
VDD = 20 V,
RL = 200 Ω,
tON
1
0.1
tOFF
VDD = 20 V,
tON
IF = 5 mA
1
tOFF
10
1
100
LED forward current IF (mA)
40
60
80
100
Current leakage vs. Load voltage
2.0
Ta = 25°C
1.5
1.0
0.1
0.5
0.01
0.1
20
ILEAK - VOFF
10
RL = 200 Ω,
0
Ambient temperature Ta (°C)
Current leakage ILEAK (nA)
10
0.01
-20
tON, tOFF - Ta
Turn ON, Turn OFF time tON, tOFF (ms)
Turn ON, Turn OFF time tON, tOFF (ms)
tON, tOFF - IF
Ta = 25°C
0.0
-40
100
Ambient temperature Ta (°C)
-40
-20
0
20
40
60
80
100
Ambient temperature Ta (°C)
0.0
0
20
40
60
80
100
Load voltage (V)
Output terminal capacitance COFF/COFF (0V)
Output terminal capacitance vs. Load voltage
COFF - VOFF
1.2
Ta = 25°C
1
0.8
0.6
0.4
0.2
0
0
10
20
30
40
Load voltage (V)
■ Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
SOP6 type
■ Appearance
SOP (Small Outline Package)
SOP6
OMRON logo
Model name
932
Pin 1 mark
LOT.No.
Note: The actual product is marked differently from the image shown here.
■ Dimensions
(Unit: mm)
Surface-mounting Terminals
Actual Mounting Pad
Dimensions
Weight: 0.13 g
4.4±0.25
(Recommended Value, TOP VIEW)
2.1 max.
6.3±0.25
6 to 6.3
1.2
0.15
0.8
2.54±0.25
0.1±0.1
0.4±0.1
Note: The actual product is marked differently from the image shown here.
0.6±0.3
7.0±0.4
2.54
2.54
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K180-E1-01
0412(0412)(O)