G3VM-81GR1

G3VM-81GR1
MOS FET Relays
MOS FET Relays Designed for Switching Minute Signals and
Analog Signals.
• Low Output Capacitance and ON Resistance (C × R = 32.5 pF • Ω)
RoHS compliant
Note: The actual product is marked differently from the
image shown here.
■ Application Examples
■ Terminal Arrangement/Internal
Connections
• Semiconductor test equipment
4
• Test & Measurement equipment
3
Mold pin
mark *
• Communication equipment
OMRON logo
• Data loggers
932
Pin 1 mark
1
Model name
LOT.No.
2
Note: The actual product is marked differently from the image shown here.
* The indentation in the corner diagonally opposite from the pin 1 mark is from
a pin on the mold.
■ List of Models
Package type Contact form
SOP4
1a
(SPST-NO)
Load voltage
(peak value) *
Terminals
Surface-mounting Terminals
80 V
Model
G3VM-81GR1
G3VM-81GR1 (TR)
Minimum package quantity
Number per tube Number per tape and reel
100
-
-
2,500
* The AC peak and DC value are given for the load voltage.
■ Absolute Maximum Ratings (Ta = 25°C)
Output
Input
Item
LED forward current
Repetitive peak LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Continuous load current (AC peak/DC)
ON current reduction rate
Connection temperature
Dielectric strength between
I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
Symbol
IF
IFP
∆IF/°C
VR
TJ
VOFF
IO
∆IO/°C
TJ
Rating
50
1
−0.5
5
125
80
200
−2.0
125
Unit
mA
A
mA/°C
V
°C
V
mA
mA/°C
°C
VI-O
1500
Vrms
Ta
Tstg
-
−20 to +85
−40 to +125
260
°C
°C
°C
Measurement conditions
100 µs pulses, 100 pps
Ta ≥ 25°C
Ta ≥ 25°C
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Note: 1. The dielectric strength between the input and
output was checked by applying voltage
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
■ Electrical Characteristics (Ta = 25°C)
Output
Input
Item
Symbol Minimum Typical Maximum
LED forward voltage
VF
1.0
1.15
1.3
Reverse current
IR
10
Capacity between terminals
CT
15
Trigger LED forward current
IFT
3
Maximum resistance with output ON
RON
5
8
Current leakage when the relay is open
ILEAK
1
Capacity between terminals
COFF
6.5
11
Capacity between I/O terminals
CI-O
0.7
Insulation resistance between I/O terminals
RI-O
1000
Turn-ON time
tON
0.13
0.5
Turn-OFF time
tOFF
0.17
0.5
1
Unit
V
µA
pF
mA
Ω
nA
pF
pF
MΩ
ms
ms
Measurement conditions
IF = 10 mA
Note: 2. Turn-ON and Turn-OFF Times
VR = 5 V
IF 1
4 RL
VDD
V = 0, f = 1 MHz
VOUT
2
3
IO = 200 mA
IF = 5 mA, IO = 200 mA
VOFF = 80 V, Ta = 50 °C
V = 0, f = 100 MHz, t < 10 s
IF
f = 1 MHz, VS = 0 V
VI-O = 500 VDC, ROH ≤ 60 %
90%
VOUT
10%
IF = 5 mA, RL = 200 Ω,
t ON
t OFF
VDD = 10 V (See note 2.)
G3VM-81GR1
MOS FET Relays
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
Unit
Load voltage (AC peak/DC)
Operating LED forward current
Continuous load current (AC peak/DC)
Ambient operating temperature
VDD
IF
IO
Ta
5
25
-
64
30
200
60
V
mA
mA
°C
■ Engineering Data
IO - Ta
100
80
60
40
LED forward current vs. LED forward voltage
IF - VF
500
LED forward current IF (mA)
Continuous load current IO (mA)
Continuous load current vs. Ambient temperature
IF - Ta
LED forward current IF (mA)
LED forward current vs. Ambient temperature
400
300
200
Ta = 25 °C
50
30
10
5
3
1
0.5
100
20
100
0.3
0
-20
0
0
-20
20
40
60
80
100
120
0
20
40
Ambient temperature Ta (°C)
60
80
100
0.1
120
0.6
0.8
1
1.2
Ambient temperature Ta (°C)
1.4
1.6
1.8
LED forward voltage VF (V)
Continuous load current vs. On-state voltage On-state resistance vs. Ambient temperature Trigger LED forward current vs. Ambient temperature
200
IF = 5 mA
100
0
-100
Trigger LED forward current IFT (mA)
RON - Ta
On-state resistance RON (Ω)
Continuous load current IO (mA)
IO - VON
Ta = 25 °C
20
IO = 200 mA
IF = 5 mA, t < 1s
15
10
5
IFT - Ta
1.5
IO = 200 mA
t < 1s
1.0
0.5
-200
-1
-0.5
0
0.5
0
-20
1
0
20
40
60
80
Ta = 25 °C
VDD = 10 V, RL = 200 Ω
1000
300
tOFF
100
30
tON
10
3
1
0.1
0.3
1
3
10
30
100
20
40
80
100
Current leakage vs. Load voltage
tON, tOFF - Ta
ILEAK - VOFF
400
VDD = 10 V, RL = 200 Ω
IF = 5 mA
300
tOFF
200
60
Ambient temperature Ta (°C)
Current leakage ILEAK (pA)
Turn ON, Turn OFF time tON, tOFF (µs)
Turn ON, Turn OFF time tON, tOFF (µs)
Turn ON, Turn OFF time vs. LED forward current Turn ON, Turn OFF time vs. Ambient temperature
3000
0
Ambient temperature Ta (°C)
On-state voltage VON (V)
tON, tOFF - IF
0
-20
100
30
Ta = 25
Ta=25
? °C
25
20
15
10
tON
100
5
0
-20
0
LED forward current IF (mA)
20
40
60
80
100
Ambient temperature Ta (°C)
0
20
40
60
80
100
Load voltage (V)
Output terminal capacitance vs. Load voltage
Output terminal capacitance COFF/COFF (0V)
COFF - VOFF
1.2
= 25 °C
Ta =Ta25
°C
1.0
0.8
0.6
0.4
0.2
0
0
10
20
30
40
Load voltage (V)
■ Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
SOP4 type
■ Appearance
SOP (Small Outline Package)
SOP4
Mold pin mark *
OMRON logo
Pin 1 mark
932
Model name
LOT.No.
Note: The actual product is marked differently from the image shown here.
* The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold.
■ Dimensions
(Unit: mm)
Surface-mounting Terminals
Actual Mounting Pad
Dimensions
Weight: 0.1 g
4.4±0.25
3.9±0.2
(Recommended Value, TOP VIEW)
2.1 max.
6 to 6.3
0.15
0.4±0.1
0.1±0.1
1.2
0.6±0.3
7.0±0.4
2.54±0.25
Note: The actual product is marked differently from the image shown here.
0.8
2.54
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K189-E1-01
0412(0412)(O)