NX-series Safety Control Units NX-SL/SI/SO CSM_NX-SL_SI_SO_E_4_2 Integration of Safety into Machine Automation Enables Simple, Flexible System Configuration. • EN ISO13849-1 (PLe/Safety Category4), IEC 61508 (SIL3) certified. • One connection using Safety over EtherCAT (FSoE) * protocol enables flexible configuration by mixing the Safety Units with standard NX I/O. • Hardware and safety circuits can be configured using the Sysmac Studio (Ver. 1.07) * Safety over EtherCAT (FSoE): The open protocol Safety over EtherCAT (abbreviated with FSoE "FailSafe over EtherCAT") defines a safety related communication layer for EtherCAT. Safety over EtherCAT meets the requirements of IEC 61508 SIL 3 and enables the transfer of safe and standard information on the same communication system without limitations with regard to transfer speed and cycle time. Features • Integrated safety into machine automation possible by connecting with the NX-series EtherCAT Coupler. • The Safety CPU Unit controls up to 128 Safety I/O Units. • 4 or 8 points per Safety Input Unit. The 4-point Safety Input Unit can be directly connected with OMRON Non-contact Switches and Singlebeam Sensors. • 2 or 4 points per Safety Output Unit. The 2-point Safety Output Unit is characterized by large output breaking current of 2.0 A. • The Safety Units can be freely allocated in any combination with standard NX I/O. • Compliant with IEC61131-3 • Safety programs can be standardized and reused efficiently by using POUs for design and operation. Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products. EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation Gmbh, Germany. Safety over EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation Gmbh, Germany. Other company names and product names in this document are the trademarks or registered trademarks of their respective companies. 1 NX-SL/SI/SO System Configuration Sysmac Studio Support Software EtherCAT master* NJ/NX-series CPU Unit Connection to peripheral USB port or built-in EtherNet/IP port on NJ-series CPU Unit Built-in EtherCAT port Sysmac Studio Support Software ●EtherCAT Slave Terminal Communications cable Ethernet cables Peripheral USB port. NX Series EtherCAT Coupler Unit NX-ECC201/ECC202 Safety CPU Unit NX-SL3300 NX-SL3500 Safety Input Unit NX-SID800 Connection to peripheral USB port on EtherCAT Coupler Unit NX Units End Cover NX Series EtherCAT Coupler Unit NX-ECC201 Safety Output Unit NX-SOD400 Safety Input Unit NX-SIH400 Safety Output Unit NX-SOH200 NX Units End Cover * OMRON CJ1W-NC@81/@82 Position Control Units cannot be connected to the EtherCAT Slave Terminal even though they support EtherCAT. 2 NX-SL/SI/SO Ordering Information Safety CPU Unit Unit type Appearance Maximum number of safety I/O points Specifications Number of safety Program capacity master connections Unit I/O refreshing method version Model 256 points 512KB 32 Free-Run refreshing Ver. 1.1 NX-SL3300 1024 points 2048KB 128 Free-Run refreshing Ver. 1.1 NX-SL3500 Unit version Model Safety CPU Unit Safety Input Units Specifications Unit type Appearance Number of safety input points Number of test output points Internal I/O common Rated input voltage OMRON special safety input devices Number of safety slave connections I/O refreshing method 4 points 2 points Sinking inputs (PNP) 24 VDC Can be connected. * 1 Free-Run refreshing Ver. 1.1 NX-SIH400 8 points 2 points Sinking inputs (PNP) 24 VDC Cannot be connected. 1 Free-Run refreshing Ver. 1.0 NX-SID800 Safety Input Units * The following OMRON special safety input devices can be connected directly without a special controller. For detail of connectable OMRON special safety input devices,refer to NX-series Safety Control Units User's Manual(No.Z930-E1). . Model and corresponding PL and safety category E3ZS and E3FS D40Z D40A UM SGE (4-wire connection) Type OMRON Single-beam Safety Sensors OMRON Non-contact Door Switches OMRON Safety Mats OMRON Safety Edges Safety Output Units Specifications Unit type Appearance Number of safety output points Internal I/O common Maximum load current Rated voltage Number of safety slave connections I/O refreshing method 2 points Sourcing outputs (PNP) 2.0 A/point, 4.0 A/Unit at 40°C, and 2.5 A/Unit at 55°C The maximum load current depends on the installation orientation and ambient temperature. 24 VDC 1 4 points Sourcing outputs (PNP) 0.5 A/point and 2.0 A/Unit 24 VDC 1 Safety Output Units Unit version Model Free-Run refreshing Ver. 1.0 NX-SOH200 Free-Run refreshing Ver. 1.0 NX-SOD400 Option Product Name Unit/Terminal Block Coding Pins Specification For 10 Units (Terminal Block: 30 pins, Unit: 30 pins) Model NX-AUX02 Specification Product name No. of terminals Terminal number indications Ground terminal mark Terminal current capacity Model 8 A/B None 10A NX-TBA082 16 A/B None 10A NX-TBA162 Terminal Block Accessories Not included. 3 NX-SL/SI/SO Specifications Regulations and Standards Certification body Standards TÜV Rheinland * UL EN ISO 13849-1: 2008 + AC: 2009 EN ISO 13849-2: 2012 IEC 61508 parts 1-7: 2010 EN 62061: 2005 EN 61131-2: 2007 EN ISO 13850: 2008 EN 60204-1: 2006 + A1: 2009 + AC: 2010 EN 61000-6-2: 2005 EN 61000-6-4: 2007 NFPA 79: 2012 ANSI RIA 15.06-1999 ANSI B11.19-2010 UL1998 IEC 61326-3-1: 2008 cULus: Listed (UL508) and ANSI/ISA 12.12.01 * Certification was received for applications in which OMRON FSoE devices are connected to each other. The NX-series Safety Control Units allow you to build a safety control system that meets the following standards. Requirements for SIL 3 (Safety Integrity Level 3) in IEC 61508, EN 62061, Safety Standard for Safety Instrumented Systems (Functional Safety of Electrical/Electronic/Programmable Electronic Safety-related Systems) Requirements for PLe (Performance Level e) and for safety category 4 in EN ISO13849-1 The NX-series Safety Control Units are also registered for C-Tick and KC compliance. General Specification Item Specification Enclosure Mounted in a panel (open) Grounding method Ground to 100 or less. Ambient operating temperature Operating environment 0 to 55C (The upper limit of the ambient operating temperature is restricted by the installation orientation.) Ambient operating humidity 10% to 95% (with no condensation or icing) Atmosphere Must be free from corrosive gases. Ambient storage temperature 25 to 70C (with no condensation or icing) Altitude 2,000 m max. Pollution degree 2 or less: Conforms to JIS B3502 and IEC 61131-2. Noise immunity Conforms to IEC 61131-2. 2 kV on power supply line (Conforms to IEC 61000-4-4.) Insulation class Class III (SELV) Overvoltage category Category II: Conforms to JIS B3502 and IEC 61131-2. EMC immunity level Zone B Conforms to IEC 60068-2-6. Vibration resistance 5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz, acceleration of 9.8 m/s2, 100 minutes each in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total) Conforms to IEC 60068-2-27. Shock resistance 147 m/s2, 3 times each in X, Y, and Z directions Insulation resistance 20 M between isolated circuits (at 100 VDC) Dielectric strength 510 VAC for 1 min between isolated circuits, leakage current: 5 mA max. Installation method DIN Track (IEC 60715 TH35-7.5/TH35-15) Applicable standards IEC 61508: 2010 SIL 3, EN 62061: 2005 SIL CL3 EN ISO 13849-1, 13849-2: 2008 PL e/Safety Category 4 UL 1998 cULus: Listed UL508, ANSI/ISA 12.12.01 EN 61131-2, C-Tick, KC: KC Registration, NK, LR 4 NX-SL/SI/SO Specifications of Individual Units Safety CPU Unit NX-SL3300/SL3500 Unit name Safety CPU Unit Model NX-SL3300 Maximum number of safety I/O points 256 points Program capacity 512 KB Number of safety master connections 32 I/O refreshing method Free-Run refreshing External connection terminals None FS indicator, VALID indicator, DEBUG indicator, TS indicator, and RUN indicator NX-SL3500 1024 points 2048 KB 128 FS indicator, VALID indicator, DEBUG indicator, TS indicator, and RUN indicator Indicators Dimensions 30 × 100 × 71 mm (W × H × D) I/O power supply method Not supplied. Current capacity of I/O power supply terminals No I/O power supply terminals NX Unit power consumption 0.90 W max. Current consumption from I/O power supply No consumption Weight 75 g max. Installation orientation and restrictions Installation orientation: 6 possible orientations Restrictions: None 5 NX-SL/SI/SO Safety Input Units NX-SIH400/SID800 Unit name Safety Input Unit Model NX-SIH400 NX-SID800 Number of safety input points 4 points 8 points Number of test output points 2 points 2 points Internal I/O common PNP (sinking inputs) Rated input voltage 24 VDC (20.4 to 28.8 VDC) OMRON special safety input devices Can be connected. Number of safety slave connections 1 I/O refreshing method Free-Run refreshing External connection terminals Screwless clamping terminal block (8 terminals) Screwless clamping terminal block (16 terminals) TS indicator, FS indicator, input indicators (yellow), and input error indicators (red) TS indicator, FS indicator, input indicators (yellow), and input error indicators (red) Cannot be connected. Indicators Safety input current 4.5 mA typical 3.0 mA typical Safety input ON voltage 11 VDC min. 15 VDC min. Safety input OFF voltage/OFF current 5 VDC max., 1 mA max. Test output type Sourcing outputs (PNP) Test output load current 25 mA max. Test output residual voltage 1.2 V max. (Between IOV and all output terminals) Test output leakage current 0.1 mA max. Dimensions 12 × 100 × 71 mm (W × H × D) Isolation method Photocoupler isolation Insulation resistance 20 MΩ min. between isolated circuits (at 100 VDC) Dielectric strength 510 VAC for 1 min between isolated circuits, leakage current: 5 mA max. I/O power supply method Power supplied from the NX bus Current capacity of I/O power supply terminals No applicable terminals. NX Unit power consumption 0.70 W max. Current consumption from I/O power supply 20 mA max. Weight 70 g max. 50 mA max. 0.75 W max. T0 and T1 Circuit layout Si0 to Si3 Left-side NX bus connector Terminal block Si0 to Si7 I/O power supply + I/O power supply + I/O power supply − I/O power supply − Right-side NX bus connector Si0 to Si3: Safety input terminals T0 and T1: Test output terminals NX-SIH400 Safety Input Unit A1 Terminal connection diagram A8 B1 Internal circuits Internal circuits T0 and T1 Terminal block Left-side NX bus connector I/O power supply + I/O power supply + I/O power supply − I/O power supply − Right-side NX bus connector Si0 to Si7: Safety input terminals T0 and T1: Test output terminals NX-SID800 Safety Input Unit Safety switch A1 B1 Si0 Si1 Si0 T0 T1 T0 T1 Si2 Si3 T0 T1 Si2 Si3 Si4 Si5 T0 T1 T0 T1 Si6 Si7 T0 T1 B8 Refer to User's manual (Z930-E1) for details. A8 Safety switch Si1 B8 Refer to User's manual (Z930-E1) for details. Installation orientation and restrictions Installation orientation: 6 possible orientations. Restrictions: Maximum ambient temperature is 50ºC for any orientation other than upright installation. Protective functions Overvoltage protection circuit and short detection (test outputs) 6 NX-SL/SI/SO Safety Output Units NX-SOH200/SOD400 Unit name Safety Output Unit Model NX- SOH200 NX-SOD400 Number of safety output points 2 points 4 points Internal I/O common PNP (sourcing outputs) Maximum load current 2.0 A/point 4.0 A/Unit at 40°C 2.5 A/Unit at 55°C The maximum load current depends on the installation orientation and ambient temperature Rated voltage 24 VDC (20.4 to 28.8 VDC) Number of safety slave connections 1 I/O refreshing method Free-Run refreshing External connection terminals Screwless clamping terminal block (8 terminals) 0.5 A/point and 2.0 A/Unit TS indicator, FS indicator, output indicators (yellow), and output error indicators (red) TS indicator, FS indicator, output indicators (yellow), and output error indicators (red) Indicators 1.2 V max. (Between IOV and all output terminals) Safety output OFF residual voltage 2 V max. (Between IOG and all output terminals) Safety output leakage current 0.1 mA max. Dimensions 12 × 100 × 71 mm (W × H × D) Isolation method Photocoupler isolation Insulation resistance 20 MΩ min. between isolated circuits (at 100 VDC) Dielectric strength 510 VAC for 1 min between isolated circuits, leakage current: 5 mA max. I/O power supply method Power supplied from the NX bus Current capacity of I/O power supply terminals IOG: 2 A max./terminal IOG (A3 and B3): 2 A max./terminal IOG (A7 and B7): 0.5 A max./terminal NX Unit power consumption 0.70 W max. 0.75 W max. Current consumption from I/O power supply 40 mA max. 60 mA max. Weight 65 g max. Circuit layout Left-side NX bus connector So0 and So1 Internal circuits Internal circuits Safety output ON residual voltage Terminal block IOG I/O power supply + I/O power supply + I/O power supply − I/O power supply − So0 and So1: Safety output terminals IOG: I/O power supply 0 V Right-side NX bus connector Left-side NX bus connector I/O power supply + I/O power supply − I/O power supply − A1 A1 B1 A8 B1 So0 So1 IOG IOG IOG NC NC So2 So3 NC NC IOG IOG IOG L Terminal connection diagram L L B8 Refer to User's manual (Z930-E1) for details. Right-side NX bus connector So0 to So3: Safety output terminals IOG: I/O power supply 0 V NX-SOD400 Safety Output Unit So1 Terminal block IOG I/O power supply + NX-SOH200 Safety Output Unit So0 So0 to So3 A8 L B8 Refer to User's manual (Z930-E1) for details. 7 NX-SL/SI/SO Unit name Model Safety Output Unit NX- SOH200 NX-SOD400 Installation orientation: 6 possible orientations Restrictions: For upright installation, the ambient temperature is restricted as shown below depending on the total Unit load current. Installation orientation: 6 possible orientations Restrictions: None Load current [A] 4 3 2.5A 2 1 0 0 Installation orientation and restrictions 10 20 30 40 50 55 Ambient temperature [°C] For all installation orientations other than upright installation, the ambient temperature is restricted as shown below according to the total Unit load current. Load current [A] 4 3 2 1 0 0 Protective functions 10 20 30 40 50 Ambient temperature [°C] Overvoltage protection circuit and short detection 8 NX-SL/SI/SO Version Information The combinations that can be used of the unit versions of the Safety Control Units, NJ/NX-series CPU Units, and NX-series EtherCAT Coupler Unit, and the version of the Sysmac Studio Corresponding version * NX Unit Model number NX-SL3300 NX-SL3500 NX-SIH400 Sysmac Studio ErherNet/IP Coupler Unit (NX-EIC202) Sysmac Studio 1.07 or later --- --- 1.10 or later 1.0 or later 1.10 or later 1.08 or later --- --- 1.10 or later --- --- 1.0 1.07 or later --- --- 1.1 1.10 or later 1.0 or later 1.10 or later Unit version 1.0 1.1 1.0 1.1 NX-SID800 NX-SOH200 EtherCAT Coupler Unit NX-ECC20@ NJ/NX-series CPU Units 1.1 or later 1.06 or later 1.2 or later 1.1 or later 1.0 1.07 or later 1.06 or later 1.07 or later NX-SOD400 * Some Units do not have all of the versions given in the above table. If a Unit does not have the specified version, support is provided by the oldest available version after the specified version. Refer to the user’s manuals for the specific Units for the relation between models and versions. 9 NX-SL/SI/SO External Interface Safety CPU Unit NX-SL3300/SL3500 (C) (C) (B) (E) (E) (B) (B) (C) (D) (A) (D) (F) (G) (E) Letter Item (E) Specification (A) Marker attachment locations The locations where markers are attached. The markers made by OMRON are installed for the factory setting. Commercially available markers can also be installed. For details, refer to User's Manual (Z930-E1). (B) Protrusions for removing the Unit The protrusions to hold when removing the Unit. (C) DIN Track mounting hooks These hooks are used to mount the NX Unit to a DIN Track. (D) NX bus connector This is the NX-series bus connector. It is used to connect an NX-series Safety I/O Unit or other NX Unit. (E) Unit hookup guides These guides are used to connect two Units. (F) Indicators The indicators show the current operating status of the NX Unit or signal I/O status. Refer to User's Manual (Z930-E1). (G) Unit specifications The specifications of the NX Unit are given here. 10 NX-SL/SI/SO Safety Input Unit NX-SIH400/SID800 Safety Output Unit NX-SOH200/SOD400 (C) (D) (E) (B) (B) (C) (F) (A) (G) (C) (H) Letter (E) (C) Item Specification (A) Marker attachment locations The locations where markers are attached. The markers made by OMRON are installed for the factory setting. Commercially available markers can also be installed. For details, refer to User's Manual (Z930-E1). (B) NX bus connector This is the NX-series bus connector. Connect this connector to another Unit, such as the NX-series Safety CPU Unit or a Safety I/O Unit. (C) Unit hookup guides These guides are used to connect two Units. (D) DIN Track mounting hooks These hooks are used to mount the NX Unit to a DIN Track. (E) Protrusions for removing the Unit The protrusions to hold when removing the Unit. (F) Indicators The indicators show the current operating status of the NX Unit or signal I/O status. Refer to User's Manual (Z930-E1). (G) Terminal block The terminal block is used to connect to external devices. It connects the safety outputs. The number of terminals depends on the NX Unit. (H) Unit specifications The specifications of the NX Unit are given here. Terminal Blocks (A) (B) A1 B1 A1 B1 A2 B2 A2 B2 A3 B3 A3 B3 A4 B4 A4 B4 A5 B5 A5 B5 A6 B6 A6 B6 A7 B7 A7 B7 A8 B8 A8 B8 (C) 8-terminal type Letter (A) 16-terminal type Item Terminal number indications Specification The terminal numbers are given by column letters A and B, and row numbers 1 to 8. The combination of the column and row gives the terminal numbers from A1 to A8 and B1 to B8. The terminal number indicators are the same regardless of the number of terminals on the terminal block, as shown above. (B) Release holes Insert a flat-blade screwdriver into these holes to connect and remove the wires. (C) Terminal holes The wires are inserted into these holes. 11 NX-SL/SI/SO Applicable Terminal Blocks for Each Unit Model Terminal Blocks Unit model number No. of terminals Model Terminal number indications Ground terminal mark Terminal current capacity NX-SIH400 NX-TBA082 8 A/B None NX-SID800 NX-TBA162 16 A/B None 10A 10A NX-SOH200 NX-TBA082 8 A/B None 10A NX-SOD400 NX-TBA082 8 A/B None 10A Applicable Wires Using Ferrules If you use ferrules, attach the twisted wires to them. Observe the application instructions for your ferrules for the wire stripping length when attaching ferrules. Always use plated one-pin ferrules. Do not use unplated ferrules or two-pin ferrules. The applicable ferrules, wires, and crimping tool are given in the following table. Terminal types Terminals other than ground terminals Manufacturer Phoenix Contact Ferrule model number Applicable wire (mm2 (AWG)) AI0,34-8 0.34 (#22) AI0,5-8 0.5 (#20) Crimping tool Phoenix Contact (The figure in parentheses is the applicable wire size.) CRIMPFOX 6 (0.25 to 6 mm2, AWG24 to 10) AI0,5-10 AI0,75-8 0.75 (#18) AI0,75-10 AI1,0-8 1.0 (#18) AI1,0-10 AI1,5-8 1.5 (#16) AI1,5-10 Ground terminals Terminals other than ground terminals Weidmuller AI2,5-10 2.0 * H0.14/12 0.14 (#26) H0.25/12 0.25 (#24) H0.34/12 0.34 (#22) H0.5/14 0.5 (#20) Weidmuller (The figure in parentheses is the applicable wire size.) PZ6 Roto (0.14 to 6 mm2, AWG 26 to 10) H0.5/16 H0.75/14 0.75 (#18) H0.75/16 H1.0/14 1.0 (#18) H1.0/16 H1.5/14 1.5 (#16) H1.5/16 * Some AWG 14 wires exceed 2.0 mm2 and cannot be used in the screwless clamping terminal block. When you use any ferrules other than those in the above table, crimp them to the twisted wires so that the following processed dimensions are achieved. Finished Dimensions of Ferrules 8 to 10 mm 1.6 mm max. (except ground terminals) 2.4 mm max. (except ground terminals) 2.0 mm max. (ground terminals) 2.7 mm max. (ground terminals) 12 NX-SL/SI/SO Using Twisted Wires/Solid Wires If you use the twisted wires or the solid wires, use the following table to determine the correct wire specifications. Terminals Classification Current capacity Wire type Twisted wires Plated 2 A max. All terminals except ground terminals Ground terminals Greater than 2 A and 4 A or less Possible Greater than 4A Possible *1 --- Possible Solid wire Unplated Plated Unplated Possible Possible Possible Not Possible Possible Possible *1 Not Possible Possible *2 Not Possible Possible *2 Wire size Conductor length (stripping length) 0.08 to 1.5 mm2 AWG28 to 16 8 to 10 mm 2.0 mm2 9 to 10 mm *1 Secure wires to the screwless clamping terminal block. Refer to the Securing Wires in the USER'S MANUAL for how to secure wires. *2 With the NX-TB@@@1 Terminal Block, use twisted wires to connect the ground terminal. Do not use a solid wire. Conductor length (stripping length) <Additional Information> If more than 2 A will flow on the wires, use plated wires or use ferrules. 13 NX-SL/SI/SO Dimensions (Unit/mm) Safety CPU Unit NX-SL3300/SL3500 100 30 71 Safety Input Units NX-SIH400/SID800 Safety Output Units NX-SOH200/SOD400 14.1 12.0 0.55 1.5 104.5 100 1.5 65.2 71 80.1 Related Manuals Cat. No. Z930 Z931 Model number Manual name Application Description NX-SL@@@@ NX-SI@@@@ NX-SO@@@@ NX-series Safety Control Unit User's Manual Learning how to use NX-series Describes the hardware, setup methods, and Safety Control Units. functions of the NX-series Safety Control Units. NX-SL@@@@ NX-series Safety Control Unit Instructions Reference Manual Learning about the specifications of instructions for the Safety CPU Unit. Describes the instructions for the Safety CPU Unit. When programming, use this manual together with the NX-series Safety Control Units User's Manual (Cat. No. Z930). 14 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2016.4 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2016 All Right Reserved.