Download

NX-series Safety Control Units
NX-SL/SI/SO
CSM_NX-SL_SI_SO_E_4_2
Integration of Safety into Machine
Automation Enables Simple,
Flexible System Configuration.
• EN ISO13849-1 (PLe/Safety Category4), IEC 61508 (SIL3) certified.
• One connection using Safety over EtherCAT (FSoE) * protocol
enables flexible configuration by mixing the Safety Units with standard
NX I/O.
• Hardware and safety circuits can be configured using the Sysmac
Studio (Ver. 1.07)
* Safety over EtherCAT (FSoE): The open protocol Safety over EtherCAT (abbreviated with FSoE "FailSafe over EtherCAT") defines a safety
related communication layer for EtherCAT. Safety over EtherCAT meets the requirements of IEC 61508 SIL 3 and enables the transfer of safe
and standard information on the same communication system without limitations with regard to transfer speed and cycle time.
Features
• Integrated safety into machine automation possible by connecting with the NX-series EtherCAT Coupler.
• The Safety CPU Unit controls up to 128 Safety I/O Units.
• 4 or 8 points per Safety Input Unit. The 4-point Safety Input Unit can be directly connected with OMRON Non-contact Switches and Singlebeam
Sensors.
• 2 or 4 points per Safety Output Unit. The 2-point Safety Output Unit is characterized by large output breaking current of 2.0 A.
• The Safety Units can be freely allocated in any combination with standard NX I/O.
• Compliant with IEC61131-3
• Safety programs can be standardized and reused efficiently by using POUs for design and operation.
Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products.
EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation Gmbh, Germany.
Safety over EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation Gmbh, Germany.
Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.
1
NX-SL/SI/SO
System Configuration
Sysmac Studio
Support Software
EtherCAT master*
NJ/NX-series CPU Unit
Connection to peripheral USB port
or built-in EtherNet/IP port on
NJ-series CPU Unit
Built-in EtherCAT port
Sysmac Studio
Support Software
●EtherCAT Slave Terminal
Communications cable
Ethernet cables
Peripheral USB port.
NX Series
EtherCAT Coupler Unit
NX-ECC201/ECC202
Safety CPU Unit
NX-SL3300
NX-SL3500
Safety Input Unit
NX-SID800
Connection to peripheral USB
port on EtherCAT Coupler Unit
NX Units
End Cover
NX Series
EtherCAT Coupler Unit
NX-ECC201
Safety Output Unit
NX-SOD400
Safety Input Unit
NX-SIH400
Safety Output Unit
NX-SOH200
NX Units
End Cover
* OMRON CJ1W-NC@81/@82 Position Control Units cannot be connected to the EtherCAT Slave Terminal even though they support EtherCAT.
2
NX-SL/SI/SO
Ordering Information
Safety CPU Unit
Unit type
Appearance
Maximum number of
safety I/O points
Specifications
Number of safety
Program capacity
master connections
Unit
I/O refreshing method version
Model
256 points
512KB
32
Free-Run refreshing
Ver. 1.1
NX-SL3300
1024 points
2048KB
128
Free-Run refreshing
Ver. 1.1
NX-SL3500
Unit
version
Model
Safety CPU
Unit
Safety Input Units
Specifications
Unit type
Appearance
Number of
safety input
points
Number of
test output
points
Internal I/O
common
Rated input
voltage
OMRON
special
safety input
devices
Number of
safety slave
connections
I/O
refreshing
method
4 points
2 points
Sinking
inputs
(PNP)
24 VDC
Can be
connected.
*
1
Free-Run
refreshing
Ver. 1.1
NX-SIH400
8 points
2 points
Sinking
inputs
(PNP)
24 VDC
Cannot be
connected.
1
Free-Run
refreshing
Ver. 1.0
NX-SID800
Safety Input
Units
* The following OMRON special safety input devices can be connected directly without a special controller.
For detail of connectable OMRON special safety input devices,refer to NX-series Safety Control Units User's Manual(No.Z930-E1).
.
Model and corresponding PL and
safety category
E3ZS and E3FS
D40Z
D40A
UM
SGE (4-wire connection)
Type
OMRON Single-beam Safety Sensors
OMRON Non-contact Door Switches
OMRON Safety Mats
OMRON Safety Edges
Safety Output Units
Specifications
Unit type
Appearance
Number of
safety
output
points
Internal I/O
common
Maximum load current
Rated
voltage
Number of
safety slave
connections
I/O
refreshing
method
2 points
Sourcing
outputs
(PNP)
2.0 A/point, 4.0 A/Unit at 40°C,
and 2.5 A/Unit at 55°C
The maximum load current
depends on the installation
orientation and ambient
temperature.
24 VDC
1
4 points
Sourcing
outputs
(PNP)
0.5 A/point and
2.0 A/Unit
24 VDC
1
Safety Output
Units
Unit
version
Model
Free-Run
refreshing
Ver. 1.0
NX-SOH200
Free-Run
refreshing
Ver. 1.0
NX-SOD400
Option
Product Name
Unit/Terminal Block Coding Pins
Specification
For 10 Units (Terminal Block: 30 pins, Unit: 30 pins)
Model
NX-AUX02
Specification
Product name
No. of
terminals
Terminal number
indications
Ground terminal
mark
Terminal current
capacity
Model
8
A/B
None
10A
NX-TBA082
16
A/B
None
10A
NX-TBA162
Terminal Block
Accessories
Not included.
3
NX-SL/SI/SO
Specifications
Regulations and Standards
Certification body
Standards







TÜV Rheinland *
UL
EN ISO 13849-1: 2008 + AC: 2009
EN ISO 13849-2: 2012
IEC 61508 parts 1-7: 2010
EN 62061: 2005
EN 61131-2: 2007
EN ISO 13850: 2008
EN 60204-1: 2006 + A1: 2009 + AC: 2010







EN 61000-6-2: 2005
EN 61000-6-4: 2007
NFPA 79: 2012
ANSI RIA 15.06-1999
ANSI B11.19-2010
UL1998
IEC 61326-3-1: 2008
cULus: Listed (UL508) and ANSI/ISA 12.12.01
* Certification was received for applications in which OMRON FSoE devices are connected to each other.
The NX-series Safety Control Units allow you to build a safety control system that meets the following standards.
 Requirements for SIL 3 (Safety Integrity Level 3) in IEC 61508, EN 62061, Safety Standard for Safety Instrumented Systems (Functional Safety
of Electrical/Electronic/Programmable Electronic Safety-related Systems)
 Requirements for PLe (Performance Level e) and for safety category 4 in EN ISO13849-1
The NX-series Safety Control Units are also registered for C-Tick and KC compliance.
General Specification
Item
Specification
Enclosure
Mounted in a panel (open)
Grounding method
Ground to 100  or less.
Ambient operating temperature
Operating
environment
0 to 55C (The upper limit of the ambient operating temperature is restricted by the
installation orientation.)
Ambient operating humidity
10% to 95% (with no condensation or icing)
Atmosphere
Must be free from corrosive gases.
Ambient storage temperature
25 to 70C (with no condensation or icing)
Altitude
2,000 m max.
Pollution degree
2 or less: Conforms to JIS B3502 and IEC 61131-2.
Noise immunity
Conforms to IEC 61131-2.
2 kV on power supply line (Conforms to IEC 61000-4-4.)
Insulation class
Class III (SELV)
Overvoltage category
Category II: Conforms to JIS B3502 and IEC 61131-2.
EMC immunity level
Zone B
Conforms to IEC 60068-2-6.
Vibration resistance
5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz, acceleration of 9.8 m/s2, 100 minutes each
in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total)
Conforms to IEC 60068-2-27.
Shock resistance
147 m/s2, 3 times each in X, Y, and Z directions
Insulation resistance
20 M between isolated circuits (at 100 VDC)
Dielectric strength
510 VAC for 1 min between isolated circuits, leakage current: 5 mA max.
Installation method
DIN Track (IEC 60715 TH35-7.5/TH35-15)
Applicable standards
IEC 61508: 2010 SIL 3, EN 62061: 2005 SIL CL3
EN ISO 13849-1, 13849-2: 2008 PL e/Safety Category 4
UL 1998
cULus: Listed UL508, ANSI/ISA 12.12.01
EN 61131-2, C-Tick, KC: KC Registration, NK, LR
4
NX-SL/SI/SO
Specifications of Individual Units
Safety CPU Unit NX-SL3300/SL3500
Unit name
Safety CPU Unit
Model
NX-SL3300
Maximum number of safety I/O points 256 points
Program capacity
512 KB
Number of safety master connections 32
I/O refreshing method
Free-Run refreshing
External connection terminals
None
FS indicator, VALID indicator, DEBUG indicator,
TS indicator, and RUN indicator
NX-SL3500
1024 points
2048 KB
128
FS indicator, VALID indicator, DEBUG indicator,
TS indicator, and RUN indicator
Indicators
Dimensions
30 × 100 × 71 mm (W × H × D)
I/O power supply method
Not supplied.
Current capacity of I/O power supply
terminals
No I/O power supply terminals
NX Unit power consumption
0.90 W max.
Current consumption from I/O power
supply
No consumption
Weight
75 g max.
Installation orientation and
restrictions
Installation orientation: 6 possible orientations
Restrictions: None
5
NX-SL/SI/SO
Safety Input Units NX-SIH400/SID800
Unit name
Safety Input Unit
Model
NX-SIH400
NX-SID800
Number of safety input points
4 points
8 points
Number of test output points
2 points
2 points
Internal I/O common
PNP (sinking inputs)
Rated input voltage
24 VDC (20.4 to 28.8 VDC)
OMRON special safety input
devices
Can be connected.
Number of safety slave
connections
1
I/O refreshing method
Free-Run refreshing
External connection terminals
Screwless clamping terminal block (8 terminals)
Screwless clamping terminal block (16 terminals)
TS indicator, FS indicator, input indicators (yellow), and input
error indicators (red)
TS indicator, FS indicator, input indicators (yellow), and input
error indicators (red)
Cannot be connected.
Indicators
Safety input current
4.5 mA typical
3.0 mA typical
Safety input ON voltage
11 VDC min.
15 VDC min.
Safety input OFF voltage/OFF
current
5 VDC max., 1 mA max.
Test output type
Sourcing outputs (PNP)
Test output load current
25 mA max.
Test output residual voltage
1.2 V max. (Between IOV and all output terminals)
Test output leakage current
0.1 mA max.
Dimensions
12 × 100 × 71 mm (W × H × D)
Isolation method
Photocoupler isolation
Insulation resistance
20 MΩ min. between isolated circuits (at 100 VDC)
Dielectric strength
510 VAC for 1 min between isolated circuits, leakage current: 5 mA max.
I/O power supply method
Power supplied from the NX bus
Current capacity of I/O power
supply terminals
No applicable terminals.
NX Unit power consumption
0.70 W max.
Current consumption from I/O
power supply
20 mA max.
Weight
70 g max.
50 mA max.
0.75 W max.
T0 and T1
Circuit layout
Si0 to Si3
Left-side NX
bus connector
Terminal block
Si0 to Si7
I/O power supply +
I/O power supply +
I/O power supply −
I/O power supply −
Right-side NX
bus connector
Si0 to Si3: Safety input terminals
T0 and T1: Test output terminals
NX-SIH400
Safety
Input Unit
A1
Terminal connection diagram
A8
B1
Internal circuits
Internal circuits
T0 and T1
Terminal block
Left-side NX
bus connector
I/O power supply +
I/O power supply +
I/O power supply −
I/O power supply −
Right-side NX
bus connector
Si0 to Si7: Safety input terminals
T0 and T1: Test output terminals
NX-SID800
Safety
Input Unit
Safety switch
A1
B1
Si0
Si1
Si0
T0
T1
T0
T1
Si2
Si3
T0
T1
Si2
Si3
Si4
Si5
T0
T1
T0
T1
Si6
Si7
T0
T1
B8
Refer to User's manual (Z930-E1) for details.
A8
Safety switch
Si1
B8
Refer to User's manual (Z930-E1) for details.
Installation orientation and
restrictions
Installation orientation: 6 possible orientations.
Restrictions: Maximum ambient temperature is 50ºC for any orientation other than upright installation.
Protective functions
Overvoltage protection circuit and short detection (test outputs)
6
NX-SL/SI/SO
Safety Output Units NX-SOH200/SOD400
Unit name
Safety Output Unit
Model
NX- SOH200
NX-SOD400
Number of safety output points
2 points
4 points
Internal I/O common
PNP (sourcing outputs)
Maximum load current
2.0 A/point
4.0 A/Unit at 40°C
2.5 A/Unit at 55°C
The maximum load current depends on the installation
orientation and ambient temperature
Rated voltage
24 VDC (20.4 to 28.8 VDC)
Number of safety slave
connections
1
I/O refreshing method
Free-Run refreshing
External connection terminals
Screwless clamping terminal block (8 terminals)
0.5 A/point and 2.0 A/Unit
TS indicator, FS indicator, output indicators (yellow), and
output error indicators (red)
TS indicator, FS indicator, output indicators (yellow), and
output error indicators (red)
Indicators
1.2 V max. (Between IOV and all output terminals)
Safety output OFF
residual voltage
2 V max. (Between IOG and all output terminals)
Safety output leakage current
0.1 mA max.
Dimensions
12 × 100 × 71 mm (W × H × D)
Isolation method
Photocoupler isolation
Insulation resistance
20 MΩ min. between isolated circuits (at 100 VDC)
Dielectric strength
510 VAC for 1 min between isolated circuits, leakage current: 5 mA max.
I/O power supply method
Power supplied from the NX bus
Current capacity of I/O power
supply terminals
IOG: 2 A max./terminal
IOG (A3 and B3): 2 A max./terminal
IOG (A7 and B7): 0.5 A max./terminal
NX Unit power consumption
0.70 W max.
0.75 W max.
Current consumption
from I/O power supply
40 mA max.
60 mA max.
Weight
65 g max.
Circuit layout
Left-side NX
bus connector
So0 and So1
Internal circuits
Internal circuits
Safety output ON
residual voltage
Terminal block
IOG
I/O power supply +
I/O power supply +
I/O power supply −
I/O power supply −
So0 and So1: Safety output terminals
IOG: I/O power supply 0 V
Right-side NX
bus connector
Left-side NX
bus connector
I/O power supply +
I/O power supply −
I/O power supply −
A1
A1
B1
A8
B1
So0
So1
IOG
IOG
IOG
NC
NC
So2
So3
NC
NC
IOG
IOG
IOG
L
Terminal connection diagram
L
L
B8
Refer to User's manual (Z930-E1) for details.
Right-side NX
bus connector
So0 to So3: Safety output terminals
IOG: I/O power supply 0 V
NX-SOD400
Safety
Output Unit
So1
Terminal block
IOG
I/O power supply +
NX-SOH200
Safety
Output Unit
So0
So0 to So3
A8
L
B8
Refer to User's manual (Z930-E1) for details.
7
NX-SL/SI/SO
Unit name
Model
Safety Output Unit
NX- SOH200
NX-SOD400
Installation orientation: 6 possible orientations
Restrictions: For upright installation, the ambient temperature
is restricted as shown below depending on the
total Unit load current.
Installation orientation: 6 possible orientations
Restrictions: None
Load current [A]
4
3
2.5A
2
1
0
0
Installation orientation and
restrictions
10
20
30
40
50 55
Ambient temperature [°C]
For all installation orientations other than upright
installation, the ambient temperature is restricted
as shown below according to the total Unit load
current.
Load current [A]
4
3
2
1
0
0
Protective functions
10
20
30
40
50
Ambient temperature [°C]
Overvoltage protection circuit and short detection
8
NX-SL/SI/SO
Version Information
The combinations that can be used of the unit versions of the Safety Control Units,
NJ/NX-series CPU Units, and NX-series EtherCAT Coupler Unit, and the version of the
Sysmac Studio
Corresponding version *
NX Unit
Model number
NX-SL3300
NX-SL3500
NX-SIH400
Sysmac Studio
ErherNet/IP
Coupler Unit
(NX-EIC202)
Sysmac Studio
1.07 or later
---
---
1.10 or later
1.0 or later
1.10 or later
1.08 or later
---
---
1.10 or later
---
---
1.0
1.07 or later
---
---
1.1
1.10 or later
1.0 or later
1.10 or later
Unit
version
1.0
1.1
1.0
1.1
NX-SID800
NX-SOH200
EtherCAT Coupler Unit
NX-ECC20@
NJ/NX-series CPU Units
1.1 or later
1.06 or later
1.2 or later
1.1 or later
1.0
1.07 or later
1.06 or later
1.07 or later
NX-SOD400
* Some Units do not have all of the versions given in the above table.
If a Unit does not have the specified version, support is provided by the oldest available version after the specified version.
Refer to the user’s manuals for the specific Units for the relation between models and versions.
9
NX-SL/SI/SO
External Interface
Safety CPU Unit
NX-SL3300/SL3500
(C)
(C)
(B)
(E)
(E)
(B)
(B)
(C)
(D)
(A)
(D)
(F)
(G)
(E)
Letter
Item
(E)
Specification
(A)
Marker attachment locations
The locations where markers are attached. The markers made by OMRON are
installed for the factory setting. Commercially available markers can also be
installed. For details, refer to User's Manual (Z930-E1).
(B)
Protrusions for removing the Unit
The protrusions to hold when removing the Unit.
(C)
DIN Track mounting hooks
These hooks are used to mount the NX Unit to a DIN Track.
(D)
NX bus connector
This is the NX-series bus connector. It is used to connect an NX-series Safety I/O
Unit or other NX Unit.
(E)
Unit hookup guides
These guides are used to connect two Units.
(F)
Indicators
The indicators show the current operating status of the NX Unit or signal I/O status.
Refer to User's Manual (Z930-E1).
(G)
Unit specifications
The specifications of the NX Unit are given here.
10
NX-SL/SI/SO
Safety Input Unit NX-SIH400/SID800
Safety Output Unit NX-SOH200/SOD400
(C) (D) (E)
(B)
(B)
(C)
(F)
(A)
(G)
(C)
(H)
Letter
(E)
(C)
Item
Specification
(A)
Marker attachment locations
The locations where markers are attached. The markers made by OMRON are
installed for the factory setting. Commercially available markers can also be
installed. For details, refer to User's Manual (Z930-E1).
(B)
NX bus connector
This is the NX-series bus connector. Connect this connector to another Unit, such as
the NX-series Safety CPU Unit or a Safety I/O Unit.
(C)
Unit hookup guides
These guides are used to connect two Units.
(D)
DIN Track mounting hooks
These hooks are used to mount the NX Unit to a DIN Track.
(E)
Protrusions for removing the Unit
The protrusions to hold when removing the Unit.
(F)
Indicators
The indicators show the current operating status of the NX Unit or signal I/O status.
Refer to User's Manual (Z930-E1).
(G)
Terminal block
The terminal block is used to connect to external devices. It connects the safety
outputs. The number of terminals depends on the NX Unit.
(H)
Unit specifications
The specifications of the NX Unit are given here.
Terminal Blocks
(A)
(B)
A1
B1
A1
B1
A2
B2
A2
B2
A3
B3
A3
B3
A4
B4
A4
B4
A5
B5
A5
B5
A6
B6
A6
B6
A7
B7
A7
B7
A8
B8
A8
B8
(C)
8-terminal type
Letter
(A)
16-terminal type
Item
Terminal number
indications
Specification
The terminal numbers are given by column letters A and B, and row numbers 1 to 8. The combination of
the column and row gives the terminal numbers from A1 to A8 and B1 to B8. The terminal number
indicators are the same regardless of the number of terminals on the terminal block, as shown above.
(B)
Release holes
Insert a flat-blade screwdriver into these holes to connect and remove the wires.
(C)
Terminal holes
The wires are inserted into these holes.
11
NX-SL/SI/SO
Applicable Terminal Blocks for Each Unit Model
Terminal Blocks
Unit model
number
No. of
terminals
Model
Terminal number
indications
Ground terminal
mark
Terminal current
capacity
NX-SIH400
NX-TBA082
8
A/B
None
NX-SID800
NX-TBA162
16
A/B
None
10A
10A
NX-SOH200
NX-TBA082
8
A/B
None
10A
NX-SOD400
NX-TBA082
8
A/B
None
10A
Applicable Wires
Using Ferrules
If you use ferrules, attach the twisted wires to them.
Observe the application instructions for your ferrules for the wire stripping length when attaching ferrules.
Always use plated one-pin ferrules. Do not use unplated ferrules or two-pin ferrules.
The applicable ferrules, wires, and crimping tool are given in the following table.
Terminal types
Terminals other
than ground
terminals
Manufacturer
Phoenix Contact
Ferrule model
number
Applicable wire
(mm2 (AWG))
AI0,34-8
0.34 (#22)
AI0,5-8
0.5 (#20)
Crimping tool
Phoenix Contact (The figure in parentheses is the applicable wire size.)
CRIMPFOX 6 (0.25 to 6 mm2, AWG24 to 10)
AI0,5-10
AI0,75-8
0.75 (#18)
AI0,75-10
AI1,0-8
1.0 (#18)
AI1,0-10
AI1,5-8
1.5 (#16)
AI1,5-10
Ground terminals
Terminals other
than ground
terminals
Weidmuller
AI2,5-10
2.0 *
H0.14/12
0.14 (#26)
H0.25/12
0.25 (#24)
H0.34/12
0.34 (#22)
H0.5/14
0.5 (#20)
Weidmuller (The figure in parentheses is the applicable wire size.)
PZ6 Roto (0.14 to 6 mm2, AWG 26 to 10)
H0.5/16
H0.75/14
0.75 (#18)
H0.75/16
H1.0/14
1.0 (#18)
H1.0/16
H1.5/14
1.5 (#16)
H1.5/16
* Some AWG 14 wires exceed 2.0 mm2 and cannot be used in the screwless clamping terminal block.
When you use any ferrules other than those in the above table, crimp them to the twisted wires so that the following processed dimensions are
achieved.
Finished Dimensions of Ferrules
8 to 10 mm
1.6 mm max. (except ground terminals)
2.4 mm max. (except ground terminals)
2.0 mm max. (ground terminals)
2.7 mm max. (ground terminals)
12
NX-SL/SI/SO
Using Twisted Wires/Solid Wires
If you use the twisted wires or the solid wires, use the following table to determine the correct wire specifications.
Terminals
Classification
Current capacity
Wire type
Twisted wires
Plated
2 A max.
All terminals except
ground terminals
Ground terminals
Greater than
2 A and 4 A or less
Possible
Greater than
4A
Possible
*1
---
Possible
Solid wire
Unplated
Plated
Unplated
Possible
Possible
Possible
Not
Possible
Possible
Possible
*1
Not
Possible
Possible
*2
Not
Possible
Possible
*2
Wire size
Conductor length
(stripping length)
0.08 to 1.5 mm2
AWG28 to 16
8 to 10 mm
2.0 mm2
9 to 10 mm
*1 Secure wires to the screwless clamping terminal block. Refer to the Securing Wires in the USER'S MANUAL for how to secure wires.
*2 With the NX-TB@@@1 Terminal Block, use twisted wires to connect the ground terminal. Do not use a solid wire.
Conductor length (stripping length)
<Additional Information> If more than 2 A will flow on the wires, use plated wires or use ferrules.
13
NX-SL/SI/SO
Dimensions
(Unit/mm)
Safety CPU Unit NX-SL3300/SL3500
100
30
71
Safety Input Units NX-SIH400/SID800
Safety Output Units NX-SOH200/SOD400
14.1
12.0
0.55
1.5
104.5
100
1.5
65.2
71
80.1
Related Manuals
Cat. No.
Z930
Z931
Model number
Manual name
Application
Description
NX-SL@@@@
NX-SI@@@@
NX-SO@@@@
NX-series Safety
Control Unit User's
Manual
Learning how to use NX-series Describes the hardware, setup methods, and
Safety Control Units.
functions of the NX-series Safety Control Units.
NX-SL@@@@
NX-series Safety
Control Unit
Instructions
Reference Manual
Learning about the
specifications of instructions
for the Safety CPU Unit.
Describes the instructions for the Safety CPU Unit.
When programming, use this manual together with
the NX-series Safety Control Units User's Manual
(Cat. No. Z930).
14
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2016.4
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2016 All Right Reserved.