G3VM-353B/E

G3VM-353B/E
MOS FET Relays
DIP 6-pin package, Analog-switching
MOS FET Relays with SPST-NC Contact.
RoHS compliant
Note: The actual product is marked differently from the
image shown here.
■ Application Examples
■ Terminal Arrangement/Internal Connections
• Communication equipment
6
5
4
• Security systems
OMRON logo
• FA systems
Model
name
LOT.NO.
932
Pin 1 mark
• Test & Measurement equipment
1
3
2
Note: The actual product is marked differently from the image shown here.
■ List of Models
Package type Contact form
DIP6
1b
(SPST-NC)
Terminals
Load voltage
(peak value) *
Model
350 V
G3VM-353B
G3VM-353E
G3VM-353E (TR)
PCB Terminals
Surface-mounting Terminals
Minimum package quantity
Number per tube Number per tape and reel
50
-
-
1,500
* The AC peak and DC value are given for the load voltage.
■ Absolute Maximum Ratings (Ta = 25°C)
Output
Input
Item
LED forward current
Repetitive peak LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Connection A
Continuous
Connection B
load current
Connection C
Connection A
ON current
reduction
Connection B
rate
Connection C
Connection temperature
Dielectric strength between I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
Symbol
IF
IFP
∆IF/°C
VR
TJ
VOFF
IO
∆IO/°C
TJ
VI-O
Ta
Tstg
-
Rating
50
1
−0.5
5
125
350
150
150
300
−1.5
−1.5
−3.0
125
2500
−40 to +85
−55 to +125
260
Unit
mA
A
mA/°C
V
°C
V
mA
mA/°C
°C
Vrms
°C
°C
°C
Measurement conditions
100 µs pulses, 100 pps
Ta ≥ 25°C
Note: 1. The dielectric strength between the input and output was
checked by applying voltage between all pins as a group on
the LED side and all pins as a group on the light-receiving side.
Connection Diagram
Connection
A
Connection A: AC peak/DC
Connection B and C: DC
Ta ≥ 25°C
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Connection
B
Connection
C
1
6
Load
2
5
3
4
or AC
DC
1
6
2
5
3
4
1
6
2
5
3
4
Load
DC
Load
DC
■ Electrical Characteristics (Ta = 25°C)
Output
Input
Item
Symbol Minimum Typical Maximum
LED forward voltage
VF
1.0
1.15
1.3
Reverse current
IR
10
Capacity between terminals
CT
30
Trigger LED forward current
IFC
1
3
Connection A
15
25
Maximum
resistance with Connection B
RON
8
14
output ON
Connection C
4
7
Current leakage when the relay is open
ILEAK
1.0
Capacity between terminals
COFF
85
Capacity between I/O terminals
CI-O
0.8
Insulation resistance between I/O terminals
RI-O
1000
Turn-ON time
tON
0.1
1.0
Turn-OFF time
tOFF
1.0
3.0
Unit
V
µA
pF
mA
Ω
Ω
Ω
µA
pF
pF
MΩ
ms
ms
Measurement conditions
IF = 10 mA
VR = 5 V
Note: 2. Turn-ON and Turn-OFF Times
V = 0, f = 1 MHz
IF 1
IOFF = 10 µA
6 RL
VDD
IO = 150 mA
VOUT
2
4
IO = 150 mA
IO = 300 mA
IF = 5 mA, VOFF = 350 V
V = 0, f = 1 MHz, IF = 5 mA
IF
f = 1 MHz, VS = 0 V
VI-O = 500 VDC, ROH ≤ 60%
90%
VOUT
10%
IF = 5 mA, RL = 200 Ω,
t ON
t OFF
VDD = 20 V(See note 2.)
1
G3VM-353B/E
MOS FET Relays
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
Load voltage (AC peak/DC)
VDD
-
-
280
Unit
V
Operating LED forward current
IF
5
-
25
mA
Continuous load current (AC peak/DC)
IO
-
-
150
mA
Ambient operating temperature
Ta
−20
-
65
°C
■ Engineering Data
LED forward current vs. Ambient
temperature
Continuous load current vs. Ambient
temperature
IO - Ta
80
60
40
20
400
Connection C
300
200
Connection A and B
0
20
40
60
80
100
20
40
60
80
100
0.6
0.8
1
1
IO = 150 mA
t<1s
15
10
-20
2
0
20
40
On-state voltage VON (V)
60
80
IOFF = 10 µA
4
3
2
1
0
-40
100
Turn ON, Turn OFF time vs. Ambient
temperature
tON, tOFF - IF
0
-20
20
VDD = 20 V, RL = 200 Ω
tOFF
500
300
tON
100
50
VDD = 20 V, RL = 200 Ω
IF = 5 mA
80
100
ILEAK - Ta
1200
tOFF
1000
60
Current leakage vs. Ambient
temperature
Current leakage ILEAK (nA)
Turn ON, Turn OFF time tON, tOFF (µs)
Ta = 25ºC
40
Ambient temperature Ta (°C)
tON, tOFF - Ta
2000
1.8
5
Ambient temperature Ta (°C)
Turn ON, Turn OFF time vs. LED
forward current
1.6
IFC - Ta
20
0
-200
1.4
Trigger LED forward current vs.
Ambient temperature
5
-100
0
1.2
LED forward voltage VF (V)
Trigger LED forward current IFC (mA)
0
1000
3
120
On-state resistance vs. Ambient
temperature
On-state resistance RON (Ω)
Continuous load current IO (mA)
100
-1
5
RON - Ta
Ta = 25°C
-2
10
Ambient temperature Ta (°C)
IO - VON
200
30
0.1
0
Ambient temperature Ta (°C)
Continuous load current vs. On-state
voltage
50
0.3
-20
120
Ta = 25°C
1
0
-20
100
0.5
100
0
Turn ON, Turn OFF time tON, tOFF (µs)
IF - VF
500
LED forward current IF (mA)
100
Continuous load current IO (mA)
LED forward current IF (mA)
IF - Ta
LED forward current vs. LED forward
voltage
800
600
1000
VOFF = 350 V
IF = 5 mA
100
10
400
tON
200
30
1
3
5
10
30
50
100
1
0
-40
-20
LED forward current IF (mA)
■ Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
0
20
40
60
80
100
Ambient temperature Ta (°C)
0
20
40
60
80
100
Ambient temperature Ta (°C)
Appearance/Dimensions
DIP6 type
■ Appearance
DIP (Dual Inline Package)
DIP6
OMRON logo
Model name
932
Pin 1 mark
LOT.NO.
Note: The actual product is marked differently from the image shown here.
■ Dimensions
(Unit: mm)
PCB Terminals
Surface-mounting
Terminals
Weight: 0.4 g
PCB Dimensions (BOTTOM VIEW)
Six, 0.8-dia. holes
2.54
Weight: 0.4 g
(0.61)
2.54
7.12±0.25
7.12±0.25
6.4±0.25
(0.61)
(1.52)
(1.52)
6.4±0.25
Actual Mounting Pad Dimensions
7.62±0.25
0.8±0.25
7.62±0.25
(Recommended Value, TOP VIEW)
3.65 +0.15
−0.25
0.25 +0.1
−0.05
2.5 min.
1.2±0.15
0.5±0.1
2.54±0.25
3.65 +0.15
−0.25
4.0 +0.25
−0.2
2.54
2.54
1.0 min.
7.85 to 8.80
1.2±0.15
2.54±0.25
Note: The actual product is marked differently from the
image shown here.
1.0 min.
10.0 max.
8.3 to 8.8
1.3
1.5
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K249-E1-01
0413(0413)(O)