G3VM-401A/D MOS FET Relays Expanded Range of Analog-switching MOS FET Relays with 400-V Load Voltage. • Continuous load current of 120 mA. • Dielectric strength of 2,500 Vrms between I/O. RoHS compliant Note: The actual product is marked differently from the image shown here. ■ Application Examples ■ Terminal Arrangement/Internal Connections • Test & Measurement equipment • Security equipment 4 3 • Amusement equipment Mold pin mark * OMRON logo Model name Pin 1 mark 1 932 LOT.NO. 2 Note: The actual product is marked differently from the image shown here. * The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold. ■ List of Models Package type Contact form Load voltage (peak value) * Terminals PCB Terminals DIP4 1a (SPST-NO) Model G3VM-401A 400 V Surface-mounting Terminals G3VM-401D G3VM-401D (TR) Minimum package quantity Number per tube Number per tape and reel 100 - - 1,500 * The AC peak and DC value are given for the load voltage. ■ Absolute Maximum Ratings (Ta = 25°C) Output Input Item LED forward current Repetitive peak LED forward current LED forward current reduction rate LED reverse voltage Connection temperature Load voltage (AC peak/DC) Continuous load current (AC peak/DC) ON current reduction rate Connection temperature Dielectric strength between I/O (See note 1.) Ambient operating temperature Ambient storage temperature Soldering temperature Symbol IF IFP ∆IF/°C VR TJ VOFF IO ∆IO/°C TJ VI-O Ta Tstg - Rating 50 1 −0.5 5 125 400 120 −1.2 125 2500 −40 to +85 −55 to +125 260 Unit mA A mA/°C V °C V mA mA/°C °C Vrms °C °C °C Measurement conditions 100 µs pulses, 100 pps Ta ≥ 25°C Ta ≥ 25°C AC for 1 min With no icing or condensation With no icing or condensation 10 s Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. ■ Electrical Characteristics (Ta = 25°C) Output Input Item Symbol Minimum Typical Maximum LED forward voltage VF 1.0 1.15 1.3 Reverse current IR 10 Capacity between terminals CT 30 Trigger LED forward current IFT 1 3 Maximum resistance with output ON RON 18 35 Current leakage when the relay is open ILEAK 1.0 Capacity between terminals COFF 40 Capacity between I/O terminals CI-O 0.8 Insulation resistance between I/O terminals RI-O 1000 Turn-ON time tON 1.0 Turn-OFF time tOFF 1.0 1 Unit V µA pF mA Ω µA pF pF MΩ ms ms Measurement conditions IF = 10 mA Note: 2. Turn-ON and Turn-OFF Times VR = 5 V IF 1 4 RL VDD V = 0, f = 1 MHz VOUT 2 3 IO = 120 mA IF = 5 mA, IO = 120 mA VOFF = 400 V V = 0, f = 1 MHz IF f = 1 MHz, VS = 0 V VI-O = 500 VDC, ROH ≤ 60% 90% VOUT 10% IF = 5 mA, RL = 200 Ω, t ON t OFF VDD = 20 V(See note 2.) G3VM-401A/D MOS FET Relays ■ Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Load voltage (AC peak/DC) VDD - - 320 Unit V Operating LED forward current IF 5 7.5 25 mA Continuous load current (AC peak/DC) IO - - 100 mA Ambient operating temperature Ta −20 - 65 °C ■ Engineering Data Continuous load current vs. Ambient temperature IF - Ta LED forward current vs. LED forward voltage IO - Ta 80 60 40 IF - VF 280 LED forward current IF (mA) 100 Continuous load current IO (mA) LED forward current IF (mA) LED forward current vs. Ambient temperature 240 200 160 120 20 40 60 80 100 0 -20 120 0 20 40 80 100 50 IF = 5mA t < 1s 40 30 20 10 2 0 -20 3 0 20 tON, tOFF - IF 3000 Ta = 25°C IF = 5mA VDD = 20V 1000 RL = 200Ω 500 300 100 60 80 tOFF tON, tOFF - Ta 1000 VDD = 20V RL = 200Ω 800 IF = 5mA tON 600 400 t < 1s 4 3 2 1 -20 0 20 40 60 80 100 Ambient temperature Ta (°C) Current leakage vs. Ambient temperature ILEAK - Ta 300 VOFF = 400V 100 30 10 3 1 200 tOFF 0.3 50 30 0.5 1.8 IO = 120mA 0 -40 100 Turn ON, Turn OFF time vs. Ambient temperature Turn ON, Turn OFF time tON, tOFF (µs) Turn ON, Turn OFF time tON, tOFF (µs) Turn ON, Turn OFF time vs. LED forward current tON 40 1.6 5 Ambient temperature Ta (°C) Current leakage ILEAK (nA) 1 On-state voltage VON (V) 1.4 IFT - Ta IO = 120mA -100 0 1.2 LED forward voltage VF (V) Trigger LED forward current IFT (mA) 0 -1 1 RON - Ta 100 -2 0.8 Trigger LED forward current vs. Ambient temperature 60 Ta = 25°C IF = 5mA -200 -3 0.1 0.6 120 On-state resistance vs. Ambient temperature On-state resistance RON (Ω) Continuous load current IO (mA) 60 Ambient temperature Ta (°C) IO - VON 200 3 0.3 Ambient temperature Ta (°C) Continuous load current vs. On-state voltage 10 1 40 0 30 80 20 0 -20 100 1 3 5 10 30 50 100 0 -40 0.1 -20 LED forward current IF (mA) 0 20 40 60 80 100 Ambient temperature Ta (°C) -20 0 20 40 60 80 100 Ambient temperature Ta (°C) ■ Safety Precautions • Refer to "Common Precautions" for all G3VM models. 2 Appearance/Dimensions DIP4 type ■ Appearance DIP (Dual Inline Package) DIP4 Mold pin mark * OMRON logo Model name Pin 1 mark 932 LOT.NO. Note: The actual product is marked differently from the image shown here. * The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold. ■ Dimensions (Unit:mm) PCB Terminals Surface-mounting Terminals PCB Dimensions (BOTTOM VIEW) Weight: 0.25 g Weight: 0.25 g Four, 0.8-dia. holes 2.54 (0.61) 2.54 4.58±0.25 4.58±0.25 6.4±0.25 Actual Mounting Pad Dimensions 7.62±0.25 7.62±0.25 0.8±0.25 3.65+0.15 –0.25 0.25 +0.1 –0.05 2.5 min. 1.2±0.15 0.5±0.1 2.54±0.25 (0.61) (1.52) (1.52) 6.4±0.25 +0.15 3.65–0.25 (Recommended Value, TOP VIEW) 2.54 4.0+0.25 –0.2 1.0 min. 7.85 to 8.80 1.2±0.15 2.54±0.25 Note: The actual product is marked differently from the image shown here. 1.0 min. 8.3 to 8.8 10.0 max. 1.3 1.5 • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. K149-E1-01 0412(0412)(O)