TPMPU12C SERIES 12W Wall Mount Switching Power Supplies For Medical Equipment Description: The 12C series of AC/DC switching mode power supplies provide 12 watts of continuous output power. This series is suitable for use in Blood Pressure measurements, Frequency Therapy Device and Dental Curing light applications. All models are designed to comply with TUV/T-mark (EN 606011) and new CE requirements. Features: Wide Input Voltage 90 to 264 VAC,47 to 63 Hz 2 Prong Plug-In Mains Connector Output Voltage Available From 5VDC Thru 27VDC Optional Output Connector (See appendix) Single Output Safety Approvals: Class II Over Voltage and Over Load protection. Over temperature Detection 3 year warranty Electrical Characteristics: Sym. Parameter Test Conditions Vin fin Input Voltage Input Frequency Operating Voltage Po Vo Output Power Range Output Voltage Range Vin=90 to 264VAC Io Iil Output Current Range Input Current (Low Line) Iih Input Current (High Line) Irl Low Line Inrush Current Irh High Line Inrush Current Eff Efficiency Min. REG-i Line Regulation Io=Full Load REG-o Load Regulation Vin=230VAC Unit 264 63 VAC Hz 90 47 Io=Full load, Vin=115VAC Io=Full load, Io=Full load, Vin=115VAC Io=Full load, Vin=230VAC Io=Full Load, Typ. Max. 0 12 See rating chart W V See rating chart 0.25 0.35 A A Vin=230VAC 25c, Cool start, 0.17 0.22 25c, Cool start, Vin=230VAC 70.8 A 14 16 A 28 30 A 72 85 % 0.5 1 % 5 % OVP Over Voltage Protection 112 132 % OCP Over Current Protection 110 150 % Ttr Time of Transient Response Io=Full Load to Half Load, Vin=100VAC Thold Hold-Up Time 10 0.3 Ts Start Up Time Io=Full Load, Vin=100VAC Ripple & Noise(Peak to Peak) Full Load, Vin=90VAC Tjsd Temperature Coefficient 1 Thermal Shutdown ○ by Junction Temperature Controller 4 Io=Full Load, Vin=110VAC Vrn TC 3 All output The parameter is not subject to production test-verified by design/characterization of integrated controller. 16 mS mS 1 2 S 0.5 1 % -0.04 0.04 %/c -25 130 c 1 As long as faulty conditions have been removed , the adaptor will automatically power up as usual. ○ Environmental : Sym. Parameter Toper Operating Temperature Tstg Storage Temperature Hr Relative Humidity T e s t Conditions 0 No-Condensing MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F Pd Derate linearly from 100% load at 50 C to 50% load at 70 C Total Power International, Inc. Min. Typ. Max. Unit Toll Free: 877-646-0900(US) 50 70 C -40 85 C 5 95 % 0.1 M Hrs www.total-power.com TPMPU12C SERIES 12W Wall Mount Switching Power Supplies For Medical Equipment Safety Specifications: Sym. Vps T e s t Conditions Parameter Dielectric Withstanding Voltage for Primary to secondary E N 5 5 0 2 2 Meet EMI requirements: EN55022 Min. Typ. Max. Primary to secondary Vin=230VAC, 50Hz Unit 5803 VDC B CLASS Output Voltage And Current Rating Chart ( Single Output ) : ① Model Number ① Output Voltage Output Current Total Regulation Maximum Output Power TPMPU12C-102 5 ~ 6 VDC 2.00 ~ 1.66 A 5% 10W TPMPU12C-103 6 ~ 8 VDC 2.00 ~ 1.50 A 5% 12W TPMPU12C-104 8 ~ 11 VDC 1.50 ~ 1.09 A 5% 12W TPMPU12C-105 11 ~ 13 VDC 1.09 ~ 0.92 A 5% 12W TPMPU12C-106 13 ~ 16 VDC 0.92 ~ 0.75 A 5% 12W TPMPU12C-107 16 ~ 21 VDC 0.75 ~ 0.57 A 3% 12W TPMPU12C-108 21 ~ 27 VDC 0.57 ~ 0.44 A 3% 12W The total regulation on model 102~103 is required to use AWG#18 / 6FT output cable. The total regulation on model 104~108 is required to use AWG#20 / 6FT output cable. The regulation and efficiency will be changed by modified output cable. Mechanical Specifications:( European Type) Note: 1. Dimensions are shown in mm. 2. Weight: 140gs approx. 3. Optional output connector: See page Appendix. (OPTIONAL) Total Power International, Inc. Toll Free: 877-646-0900(US) www.total-power.com