TPMPU12C SERIES - Total Power International

TPMPU12C SERIES
12W Wall Mount Switching Power Supplies For Medical Equipment
Description:
The 12C series of AC/DC switching mode power supplies
provide 12 watts of continuous output power.
This series is suitable for use in Blood Pressure measurements,
Frequency Therapy Device and Dental Curing light applications.
All models are designed to comply with TUV/T-mark (EN 606011) and new CE requirements.
Features:
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
2 Prong Plug-In Mains Connector
Output Voltage Available From 5VDC Thru 27VDC
Optional Output Connector (See appendix)
Single Output
Safety Approvals:
Class II
Over Voltage and Over Load protection.
Over temperature Detection
3 year warranty
Electrical Characteristics:
Sym.
Parameter
Test Conditions
Vin
fin
Input Voltage
Input Frequency
Operating Voltage
Po
Vo
Output Power Range
Output Voltage Range
Vin=90 to 264VAC
Io
Iil
Output Current Range
Input Current (Low Line)
Iih
Input Current (High Line)
Irl
Low Line Inrush Current
Irh
High Line Inrush Current
Eff
Efficiency
Min.
REG-i Line Regulation
Io=Full Load
REG-o Load Regulation
Vin=230VAC
Unit
264
63
VAC
Hz
90
47
Io=Full load, Vin=115VAC
Io=Full load,
Io=Full load,
Vin=115VAC
Io=Full load,
Vin=230VAC
Io=Full Load,
Typ. Max.
0
12
See rating chart
W
V
See rating chart
0.25 0.35
A
A
Vin=230VAC
25c, Cool start,
0.17 0.22
25c, Cool start,
Vin=230VAC
70.8
A
14
16
A
28
30
A
72
85
%
0.5
1
%
5
%
OVP
Over Voltage Protection
112
132
%
OCP
Over Current Protection
110
150
%
Ttr
Time of Transient Response Io=Full Load to Half Load, Vin=100VAC
Thold Hold-Up Time
10
0.3
Ts
Start Up Time
Io=Full Load, Vin=100VAC
Ripple & Noise(Peak to Peak)
Full Load, Vin=90VAC
Tjsd
Temperature Coefficient
1
Thermal Shutdown ○
by
Junction Temperature
Controller
4
Io=Full Load, Vin=110VAC
Vrn
TC
3
All output
The parameter is not subject
to production test-verified
by design/characterization
of integrated controller.
16
mS
mS
1
2
S
0.5
1
%
-0.04
0.04
%/c
-25
130
c
1 As long as faulty conditions have been removed , the adaptor will automatically power up as usual.
○
Environmental :
Sym.
Parameter
Toper
Operating Temperature
Tstg
Storage Temperature
Hr
Relative Humidity
T e s t Conditions
0
No-Condensing
MTBF
Operating Temperature at 25 C, Calculated per MIL-HDBK-217F
Pd
Derate linearly from 100% load at 50 C to 50% load at 70 C
Total Power International, Inc.
Min. Typ. Max. Unit
Toll Free: 877-646-0900(US)
50
70
C
-40
85
C
5
95
%
0.1
M Hrs
www.total-power.com
TPMPU12C SERIES
12W Wall Mount Switching Power Supplies For Medical Equipment
Safety Specifications:
Sym.
Vps
T e s t Conditions
Parameter
Dielectric Withstanding Voltage
for Primary to secondary
E N 5 5 0 2 2 Meet EMI requirements: EN55022
Min. Typ. Max.
Primary to secondary
Vin=230VAC, 50Hz
Unit
5803
VDC
B
CLASS
Output Voltage And Current Rating Chart ( Single Output ) :
①
Model Number
①
Output Voltage
Output Current
Total
Regulation
Maximum
Output Power
TPMPU12C-102
5 ~
6 VDC
2.00 ~ 1.66 A
5%
10W
TPMPU12C-103
6 ~
8 VDC
2.00 ~ 1.50 A
5%
12W
TPMPU12C-104
8 ~ 11 VDC
1.50 ~ 1.09 A
5%
12W
TPMPU12C-105
11 ~ 13 VDC
1.09 ~ 0.92 A
5%
12W
TPMPU12C-106
13 ~ 16 VDC
0.92 ~ 0.75 A
5%
12W
TPMPU12C-107
16 ~ 21 VDC
0.75 ~ 0.57 A
3%
12W
TPMPU12C-108
21 ~ 27 VDC
0.57 ~ 0.44 A
3%
12W
The total regulation on model 102~103 is required to use AWG#18 / 6FT output cable.
The total regulation on model 104~108 is required to use AWG#20 / 6FT output cable.
The regulation and efficiency will be changed by modified output cable.
Mechanical Specifications:( European Type)
Note:
1. Dimensions are shown in mm.
2. Weight: 140gs approx.
3. Optional output connector:
See page Appendix.
(OPTIONAL)
Total Power International, Inc.
Toll Free: 877-646-0900(US)
www.total-power.com