MPU63 SERIES 63W Desk Top Switching Power Supplies For Medical Equipment. Description: The MPU63 series of AC/DC switching mode power supplies provide 63 Watts of continuous output power. All supplies are UL94V-1 min compliant. They are suited for use in hospital instrument and many other applications. All models meet FCC Part-18 class B and CISPR-11 EN55011 class B emission Limits and are designed to comply with UL/c-UL(UL 60601-1:2ndEdition) ,TUV/T-mark (EN 60601-1:2ndEdition), and new CE requirements. All units are 100% burned in and tested. Features: Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz IEC-320-C14 Input Inlet Single Output Optional Output Connector (See appendix) Input Surge Current, Over Voltage And Over Load protection Output Voltage Protection(Crowbar Design) Energy Star 2.0, Efficiency level V Class I 3 year warranty Safety Approvals : EN 60601-1 S&E IEC 60601-1 PS E RT PS E Agree to apply for the PSE if order on hand Electrical Characteristics: Sym. Parameter Test Conditions Vin Safety Approvals Input Voltage Range fin Po Vo Io Operate Voltage Range Input Frequency Output Power Range Output Voltage Range Output Current Range Vin=90 to 264VAC Iil Iih Input Current (Low Line) Input Current ( High Line) Io=Full load, Vin=115 VAC Io=Full load, Vin=230 VAC I rl Low Line Inrush Current I rh High Line Inrush Current Io=Full load, 25 C , Cool start, Vin= 115VAC Io=Full load, 25 C , Cool start, Vin= 230VAC Io=Full Load, Vin=230VAC Eff REG-i REG -o OVP OCP Ttr Thold Ts Vp-p Ilk Pno TC Efficiency Line Regulation Load Regulation Over Voltage Protection Min. Typ. Max. Unit 100 240 VAC 90 264 63 VAC Hz W V A 47 63 0 See rating chart See rating chart 77 Io=Full Load Vin=230VAC 1.62 0.72 A A 28 38 A 45 55 A 85 88 0.5 3 1 7 132 % % % 112 Over Current Protection 110 150 Time of Transient Response Io=Full Load to Half Load, Vin=100VAC 4 Hold-Up Time Io=Full Load, Vin=110VAC 16 Io=Full Load, Vi n= 10 0V AC Start Up Time 0.3 1 2 Ripple & Noise (Peak to Peak) Full Load, Vin=100VAC 0.5 1 Safety Ground Leakage C urrent Io = Fu ll Load, Vin=240VAC 0.1 No-Load Power Consumption No load,Vin=230VAC 0.3 0.4 0.5 Temperature Coefficient -0.04 All output 0.04 % % mS mS S % mA W %/ C Environmental : Sym. Toper Parameter T e s t Conditions Operating Temperature Min. Typ. Max. Unit 50 70 C Storage Temperature -40 85 C Operating Humidity 0 95 % 0 75 Tstg Ho Hr Storage Humidity MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F Pd Derate linearly from 100% load at 50 C to 50% load at 70 C 0 0.1M % Hrs MPU63 SERIES 63W Desk Top Switching Power Supplies For Medical Equipment. Safety Specifications: Parameter Sym. Test Conditions Dielectric Withstanding Voltage for Primary to secondary Dielectric Withstanding Voltage Vpg for Primary to Ground Ris Isolation Resistance CISPR EMI requirements for CISPR-11 FCC EMI requirements for FCC PART-18 Vps Min. Typ. Max. Unit Primary to secondary 5656 VDC Primary to ground 2828 VDC 50 B B M CLASS CLASS Test Voltage = 500VDC Vin=220VAC Vin=110VAC Output Voltage And Current Rating Chart (Single Output) : Model Number MPU63-102 MPU63-103 MPU63-104 MPU63-105 MPU63-106 MPU63-107 MPU63-108 MPU63-109 MPU63-110 * * * * * * Output Voltage 5 7 9 12 15 18 24 30 36 VDC VDC VDC VDC VDC VDC VDC VDC VDC Output Current 9.00 7.85 6.44 5.25 4.20 3.50 2.62 2.10 1.75 Total Regulation ① A A A A A A A A A 7% 7% 5% 5% 5% 5% 3% 3% 3% M aximum Output Power 45W 55W 58W 63W 63W 63W 63W 63W 63W MPU63-103~109 had been approved by PSE . Mark “ ① * ” means approved by CEC level V and the output cable must be using as below. MPU63-102~103 are required to use AWG#16 / 5C/4FT output cable. MPU63-104~105 are required to use AWG#16 /2C/ 4FT output cable. MPU63-106~107 are required to use AWG#16 /2C/ 4FT output cable. MPU63-108~110 are required to use AWG#18 /2C/ 6FT output cable. The regulation and efficiency will be changed by modified output cable. Mechanical Specifications: Note: 1. Dimensions are shown in inches or mm. 2. Weight: 510-560gs approx. 3. Optional output connector: See page Appendix.