MPU60A SERIES 63W Desk Top Switching Power Supplies For Medical Equipment Description: The MPU60A series of AC/DC switching mode power supplies provide 63 Watts of continuous output power . All supplies are UL94V-1 min compliant, include IEC-320-C14 input for worldwide applications. They are suited for use in hospital instrument and many other applications. All models meet FCC Part-18 class B and CISPR-11 EN55011 class B emission Limits and are designed to comply with UL/c-UL(UL 60601-1) ,TUV/T-mark (EN 60601-1), and new CE requirements. All units are 100% burned in and tested. Features: Wide Input Voltage 90 to 264 VAC,47 to 63 Hz IEC-320-C14 Input Inlet Single Output Output Voltage Available From 12VDC Thru 36VDC Optional Output Connector (See appendix) Input Surge Current, Over Voltage And Over Load protection Output Voltage Protection(Crowbar Desing) CEC level V and Engergy Star 2.0 Compliance Class I 3 year warranty Safety Approvals : EN 60601-1 IEC 60601-1 Electrical Characteristics: Sym. * Parameter Test Conditions Vin fin Po Vo Io Input Voltage Input Frequency Output Power Range Output Voltage Range Output Current Range Vin=90 to 264VAC Iil Iih Input Current (Low Line) Input Current ( High Line) Io=Full load, Vin=115 VAC Io=Full load, Vin=230 VAC I rl Low Line Inrush Current I rh High Line Inrush Current Io=Full load, 25 C , Cool start, Vin= 115VAC Io=Full load, 25 C , Cool start, Vin= 230VAC Io=Full Load, Vin=230VAC Operating Voltage Min. Typ. Max. Unit 264 63 90 47 63 0 See rating chart See rating chart 1.62 0.72 A A 26 30 A 43 47 A 92 % % % Eff REG-i REG -o Efficiency OVP 112 Over Current Protection 110 150 Time of Transient Response Io=Full Load to Half Load, Vin=100VAC 4 Hold-Up Time Io=Full Load, Vin=110VAC 16 Io=Full Load, Vi n= 10 0V AC Start Up Time 0.3 1 2 Ripple & Noise (Peak to Peak) Full Load, Vin=100VAC 1 Safety Ground Leakage C urrent Io = Fu ll Load, Vin=240VAC 0.1 No-Load Power Consumption No load,Vin=240VAC 0.3 0.4 0.5 Temperature Coefficient -0.04 All output 0.04 OCP Ttr Thold Ts Vrn Ilk Pno TC Line Regulation Load Regulation Over Voltage Protection VAC Hz W V A 87 Io=Full Load Vin=230VAC 1 5 132 % % mS mS S % mA W %/ C * Note: The specifics for testing the energy efficiency of MPU60 Series are outlined in a separate document titled "Test Method for Calculating the Energy Efficiency of Single-Voltage External Ac-Dc and Ac-Ac PowerSupplies (August 11, 2004)," which is available on the ENERGY STAR Website. Environmental : Sym. Toper Tstg Hr MTBF Pd Parameter Test Conditions Operating Temperature Storage Temperature Relative Humidity Operating Temperature at 25 C, Calculated per MIL-HDBK-217F Derate linearly from 100% load at 50 C to 50% load at 70 C - 17 - Min. Typ. Max. Unit 50 C C % Hrs 0 -40 5 0.1M 70 85 95 MPU60A SERIES 63W Desk Top Switching Power Supplies For Medical Equipment Safety Specifications: Sym. Parameter Test Conditions Vps Dielectric Withstanding Voltage for Primary to secondary Dielectric Withstanding Voltage Vpg for Primary to Ground Ris Isolation Resistance CISPR EMI requirements for CISPR-11 FCC EMI requirements for FCC PART-18 Min. Typ. Max. Unit Primary to secondary 5656 VDC Primary to ground 2800 VDC 50 B B M CLASS CLASS Test Voltage = 2100VDC Vin=220VAC Vin=110VAC Output Voltage And Current Rating Chart (Single Output) : Model Number * * Output Voltage MPU60A-105 MPU60A-106 MPU60A-107 MPU60A-108 MPU60A-109 MPU60A-110 12 15 18 24 30 36 VDC VDC VDC VDC VDC VDC Output Current 5.25 4.20 3.50 2.62 2.10 1.75 Total Regulation A A A A A A 5% 5% 5% 3% 3% 3% M aximum Output Power 63W 63W 63W 63W 63W 63W Mark " * " means " PSE approval " The total regulation on model 105~107 is required to use AWG#16/2C/4FT output cable. The total regulation on model 108~110 is required to use AWG#18/2C/6FT output cable. The regulation and efficiency will be changed by modified output cable. Note: 1. Dimensions are shown in inches or mm. 2. Weight: 330-380gs approx. 3. Optional output connector: See page Appendix. Mechanical Specifications: - 18 -