● ● ● ● ● ● Features Unregulated Converters Description UL/CSA and EN Safety certified EN-60601 for Medical Applications Isolation 6.4kVDC Optional Continuous Short Circuit Protected /X2 Option for >9mm Input/Output Clearance Suitable for IGBT Applications ECONOLINE DC/DC-Converter with 3 year Warranty The RxxPxxS_D Series of DC/DC Converters are certified to UL/CSA-60950 as well as EN60950 and EN60601. This makes them ideal for medical and safety applications where approved isolation is required. 1 Watt SIP 7 Single & Dual Output Selection Guide Part Number SIP 7 Input Voltage (VDC) Output Voltage (VDC) Output Current (mA) Efficiency Std (%) Max Capacitive Load(1) RxxP3.3S* 5, 9, 12, 15, 24 3.3 303 70 2200µF RxxP05S* 5, 9, 12, 15, 24 5 200 70-75 1000µF RxxP09S* 5, 9, 12, 15, 24 9 111 70-75 1000µF RxxP12S* 5, 9, 12, 15, 24 12 84 70-75 470µF RxxP15S* 5, 9, 12, 15, 24 15 66 75-80 470µF RxxP3.3D* 5, 9, 12, 15, 24 ±3.3 ±151 70 ±1000µF RxxP05D* 5, 9, 12, 15, 24 ±5 ±100 70-75 ±470µF RxxP09D* 5, 9, 12, 15, 24 ±9 ±55 70-75 ±470µF RxxP12D* 5, 9, 12, 15, 24 ±12 ±41 70-75 ±220µF RxxP15D* 5, 9, 12, 15, 24 ±15 ±33 75-80 ±220µF RxxP1509D* 12, 24 +15/-9 +33/-56 70-80 ±220µF R05P1509D* 5 +15/-9 ±42 70-80 +68µF/-220µF xx = Input Voltage. Other input and output voltage combinations available on request. RoHS E-358085 2011/65EU 6/6 EN-60950-1 Certified IEC/EN-60601-1 Certified* CSA/UL-60950-1 Certified* * +15/-9 Version excluded * add Suffix “P” for Continuous Short Circuit Protection, e.g. R05P05S/P, R05P05D/P * add Suffix “/X2” for single output with alternative pinout, e.g. R05P05S/X2, R05P05S/P/X2 RxxPxx Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up) Input Voltage Range ±10% Output Voltage Accuracy ±5% Load Voltage Regulation 3.3, 5V output types 15% max. Derating-Graph (10% to 100% full load) other output types, RxxP1509D 10% max. (Ambient Temperature) Line Voltage Regulation 1.2%/1% of Vin typ. Output Ripple and Noise (20MHz BW) 200mVp-p max. 20kHz min. / 50kHz typ. / 85kHz max. RxxP1509D 20kHz min. / 60kHz typ. Efficiency at Full Load 65% min. / 75% typ. Minimum Load = 0% Specifications valid for 10% minimum load only Isolation Voltages (tested for 1 second) (rated for 1 minute**) Isolation Capacitance 6400VDC 3200VAC / 60Hz 4pF min. / 10pF max. Isolation Resistance 15 GΩ min. Short Circuit Protection 1 Second P-Suffix Operating Temperature Range (free air convection, without derating) Storage Temperature Range Continuous 100 80 Output Power (%) Operating Frequency 60 40 Safe Operating Area 20 0 -40 0 50 90 100 95 Operating Temperature °C -40°C to +90°C (see Graph) -55°C to +125°C Relative Humidity 95% RH **Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes. continued on next page Refer to Application Notes www.recom-power.com REV: 1/2015 E-69 150 RxxPxxS_D Series ECONOLINE DC/DC-Converter Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)) Package Weight 4.3g Packing Quantity 25 pcs per Tube } 2974 x 103 hours 728 x 103 hours MTBF (+25°C) Detailed Information see using MIL-HDBK 217F Application Notes chapter "MTBF" (+85°C) using MIL-HDBK 217F Certifications UL/cUL General Safety Report: E358085-A8 EN General Safety Report: SPCLVD1305069 EN Medical Safety Report: SPCMDD1205098-4 UL 60950-1 2nd Ed. EN60950-1:2006 + A12: 2011 IEC/EN60601-1:2006, 3rd Edition Notes Note 1 Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter. Tolerance Envelope +10% Typical L o +5% +5% ad Line V Nom. 1.5% Output Voltage 5% 10% 50% 100% Typical Characteristics Deviation / Load Efficiency / Load 25.000 100 R05P09S Deviation from Nominal (%) 20.000 60 R12P05S 40 Efficiency % RxxP05S RxxP09S R05P05S 80 R12P09S 20 0 0% 20% 40% 60% 80% 15.000 0.000 -5.000 -10.000 0% 20% 40% 60% Total Output current (%) 80% 100% 25.000 R05P05D R05P09D 20.000 Deviation from Nominal (%) 80 60 R12P09D 40 R12P05D 20 0% 20% 40% Total Output current (%) E-70 R12P05S Deviation / Load Efficiency / Load 0 R05P09S R05P05S 5.000 100% 100 RxxP05D RxxP09D R12P05D 10.000 Total Output current (%) Efficiency % RxxPxx Output Load Current (%) REV: 1/2015 60% 80% 100% 15.000 R12P09D R05P09D R05P05D 10.000 5.000 0.000 -5.000 -10.000 R12P05D 0% 20% 40% 60% Total Output current (%) 80% 100% www.recom-power.com RxxPxxS_D Series ECONOLINE DC/DC-Converter Typical Characteristics RxxP12S RxxP15S Efficiency / Load Deviation / Load 100 25.000 R12P12S R24P15S 20.000 Deviation from Nominal (%) 80 60 Efficiency % 40 R24P12S 20 0 0% 20% 40% 80% 60% 100% R24P12S R12P12S 15.000 10.000 5.000 0.000 R24P15S -5.000 -10.000 Total Output current (%) 0% 20% 40% 60% Total Output current (%) 80% 100% RxxP12D RxxP15D Deviation / Load Efficiency / Load 100 25.000 R12P12D R24P12D 20.000 60 Efficiency % 40 R24P15D 20 0 0% 20% 40% 80% 60% 100% Total Output current (%) R24P12D R12P12D 15.000 10.000 5.000 0.000 R24P15D -5.000 -10.000 RxxPxx Deviation from Nominal (%) 80 0% 20% 40% 60% Total Output current (%) 80% 100% Application IGBT Application Circuit IGBT Driver Control Signal Rg IGBT +Vout 7 1 C2 + -Vin Isolated DC/DC Converter C1 + 2 6 C3 + 5 -Vout www.recom-power.com REV: 1/2015 E-71 RxxPxxS_D Series ECONOLINE DC/DC-Converter Package Style and Pinning (mm) 7 PIN SIP Package 9.8 12.5 4.1 RECOM R05P05D **** 7.62 0.5 1 2 0.5 Bottom View 1.00ø+0.15/0 2.54 15.24 2.54 RxxPxx Top View 1.00ø+0.15/0 2.54 19.5 0.25 5 6 7 1 2 5 7 RECOM RxxPxxS/X2 **** 5 6 7 1 2 6 7 Pin Connections Pin # 1 2 5 6 7 Single +Vin -Vin –Vout No Pin +Vout Dual +Vin –Vin –Vout Com +Vout /X2 +Vin –Vin No Pin –Vout +Vout XX.X ± 0.5 mm XX.XX ± 0.25 mm 2.4 1.9 RECOM RxxPxxS **** RECOM RxxP1509D **** 1 2 /X2 Bottom View RECOM RxxPxxD 0.25 2.4 1.9 Single Output Recommended Footprint Details pin clearance 19.5 Dual Output 10.16 pin clearance 2.54 /X2 Top View The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. E-72 REV: 1/2015 www.recom-power.com