● Features ● ● Regulated Converters ● ● ● ● Connector Set available Class II Power Supply Universal Input Voltage Range compact 4“ x 2“ size 3kVAC Isolation OCP, OVP, SCP Standby Power ErP conform (<0.5W) The RAC48/OF series offers compact AC/DC open frame power supplies with universal AC input (90-265VAC) and fully protected DC outputs which are trimmable to compensate for voltage drops on the output connections. The power supplies are CB, UL, and CE certified and ErP conform. Uses include industry controls, test and measurement systems and energy efficient products. Description Selection Guide Part Number Input Output Output Voltage Adj. Range Voltage Current Range Range * (VAC) (VDC) (A) (V) RAC48-05S/OF 90-264 5 0-8 4.5-5.5 Output Power (W) 40 POWERLINE AC/DC-Converter with 3 year Warranty 48 Watt Open Frame Single Output Efficiency Max. typ. Capacitive % Load 79 18800µF RAC48-12S/OF 90-264 12 0-4 10-13 48 82 18800µF RAC48-15S/OF 90-264 15 0-3.2 13.5-18 48 84 12700µF RAC48-24S/OF 90-264 24 0-2 22-27 48 85 4700µF * refer to „Package Style and Pinning“ Specifications (typical at 25°C and 230VAC) RoHS 90-264VAC or 127-370VDC Rated Power 48 Watts max. Input Frequency Range (for AC Input) 47-63Hz Operating Frequency 65kHz typ. Input Current (full load) 115VAC 1.5A max. 230VAC 1A max. Inrush Current (Cold Start) 115VAC 30A typ. 230VAC 60A typ. No Load Power Consumption <0.5W Start-up Time (at cold first start) 115VAC/230VAC 500ms Rise Time Full Load <30ms Hold Time 115VAC, Full Load 13ms typ. 230VAC, Full Load 60ms typ. Leakage Current 240VAC <0.75mA Output Voltage Accuracy 24VDC ±1% (includes Line-, Load-regulation and Set-up Tolerance) 05, 12, 15VDC Output Ripple and Noise (20MHz limited) ±2% 5VDC 80mVp-p max. 12VDC 120mVp-p max. 15VDC 150mVp-p max. (measured with 0.1μF & 47μF parallel capacitor) 24VDC 200mVp-p max. Isolation Voltage I/P to O/P Isolation Resistance I/P to FG 1.5kVAC / 1 minute O/P to FG 0.5kVAC / 1 minute 500VDC Short Circuit Protection Over Voltage Protection Latch Mode, re-power on to recover Over Load Protection 3kVAC / 1 minute 100 MΩ Hiccup Mode, Automatic Restart 5VDC 5.75-6.5VDC 12VDC 13.5-15VDC 15VDC 16.9-18.75VDC 24VDC 27-30VDC 115-150% rated output power, Hiccup Mode, Automatic Restart 2011/65/EU 6/6 E196683 CB-Report UL-60950-1 Certified EN-60950-1 Certified EN-55022 Certfied EN-55024 Certified RAC48/OF Derating-Graph (Ambient Temperature) 100 Output Power (%) Input Voltage Range 80 50 60 40 20 0 0 20 50 -20 70 Ambient Temperature Range (°C) Refer to Application Notes continued on next page www.recom-power.com REV: 2/2015 PA-53 RAC48-xx/OF Series POWERLINE AC/DC-Converter Specifications (typical at 25°C and 230VAC) Operating Temperature Range Full Load without derating -20°C to +50°C with derating -20°C to +70°C Storage Temperature Range -40°C to +80°C Operation Humidity non-condensing 20% - 90% RH Storage Humidity 10% - 90% RH Vibration 10-500Hz, 2G, 10 Min. along X, Y and Z Weight 145g Dimensions (LxWxH) 101.6 x 50.8 x 30mm Package Quantity 30pcs / carton Package Dimensions Carton (LxWxH) 325 x 270 x 220mm MTBF (using MIL-HDBK-217F, 25°C) >450 x 10³ hours Certifications: General Safety Report: E196683 IEC/EN General Safety Report: PSE103-0658 EMC UL-60950-1 2nd IEC/EN-60950-1 2nd Conducted and Radiated Report: HA080035-SCCE EN55022, Class B Immunity Report: HA080035-SCCE EN55024 Report: HA080035-SBFD FCC, Part 15, Class B Report: HA080035-SCCE EN61000-3-2 Harmonics EN61000-3-3 EN61000-4-2, 3, 4, 5, 6, 8, 11, Critertia A Emission ErP Notes Note1: EN61000-6-3 2004/125/EC Mounting holes A, B must be grounded for EMI (Filter Ground). Package Style and Pinning 101.6 95.3 3.175 POWER LED 2 50.8 44.5 1 CN1 1 CN2 2 3 4 AC Input Connector (CN1): Pin# Terminal 1 AC/N WST I39606PS-2 or equivalent 2 AC/L Mating Housing WST P3-I39606 or equivalent B A 3.175 TRIM VR F.G. F.G. 4x 3.3 DC Output Connector (CN2): Pin# Terminal 1, 2 V+ WST I39606PS-2 or equivalent 3, 4 V- Mating Housing WST P4-I39606 or equivalent Note: Detail information about the connectors on www.wst.com.tw 30 RAC48/OF Report: HA080035-SCCE complies to European Directive for Energy Related Products The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. PA-54 REV: 2/2015 www.recom-power.com