RAC48/OF - recom

●
Features
●
●
Regulated
Converters
●
●
●
●
Connector Set available
Class II Power Supply
Universal Input Voltage Range
compact 4“ x 2“ size
3kVAC Isolation
OCP, OVP, SCP
Standby Power ErP conform (<0.5W)
The RAC48/OF series offers compact AC/DC open frame power supplies
with universal AC input (90-265VAC) and fully protected DC outputs which
are trimmable to compensate for voltage drops on the output connections.
The power supplies are CB, UL, and CE certified and ErP conform.
Uses include industry controls, test and measurement systems and energy
efficient products.
Description
Selection Guide
Part
Number
Input Output
Output
Voltage Adj.
Range Voltage Current Range Range *
(VAC)
(VDC)
(A)
(V)
RAC48-05S/OF 90-264
5
0-8
4.5-5.5
Output
Power
(W)
40
POWERLINE
AC/DC-Converter
with 3 year Warranty
48 Watt
Open Frame
Single Output
Efficiency Max.
typ.
Capacitive
%
Load
79
18800µF
RAC48-12S/OF 90-264
12
0-4
10-13
48
82
18800µF
RAC48-15S/OF 90-264
15
0-3.2
13.5-18
48
84
12700µF
RAC48-24S/OF 90-264
24
0-2
22-27
48
85
4700µF
* refer to „Package Style and Pinning“
Specifications (typical at 25°C and 230VAC)
RoHS
90-264VAC or 127-370VDC
Rated Power
48 Watts max.
Input Frequency Range (for AC Input)
47-63Hz
Operating Frequency
65kHz typ.
Input Current (full load)
115VAC
1.5A max.
230VAC
1A max.
Inrush Current (Cold Start)
115VAC
30A typ.
230VAC
60A typ.
No Load Power Consumption
<0.5W
Start-up Time (at cold first start)
115VAC/230VAC
500ms
Rise Time
Full Load
<30ms
Hold Time
115VAC, Full Load
13ms typ.
230VAC, Full Load
60ms typ.
Leakage Current
240VAC
<0.75mA
Output Voltage Accuracy
24VDC
±1%
(includes Line-, Load-regulation and Set-up Tolerance) 05, 12, 15VDC
Output Ripple and Noise (20MHz limited)
±2%
5VDC
80mVp-p max.
12VDC
120mVp-p max.
15VDC
150mVp-p max.
(measured with 0.1μF & 47μF parallel capacitor)
24VDC
200mVp-p max.
Isolation Voltage
I/P to O/P
Isolation Resistance
I/P to FG
1.5kVAC / 1 minute
O/P to FG
0.5kVAC / 1 minute
500VDC
Short Circuit Protection
Over Voltage Protection
Latch Mode, re-power on to recover
Over Load Protection
3kVAC / 1 minute
100 MΩ
Hiccup Mode, Automatic Restart
5VDC
5.75-6.5VDC
12VDC
13.5-15VDC
15VDC
16.9-18.75VDC
24VDC
27-30VDC
115-150% rated output power, Hiccup Mode, Automatic Restart
2011/65/EU
6/6
E196683
CB-Report
UL-60950-1 Certified
EN-60950-1 Certified
EN-55022 Certfied
EN-55024 Certified
RAC48/OF
Derating-Graph
(Ambient Temperature)
100
Output Power (%)
Input Voltage Range
80
50
60
40
20
0
0
20
50
-20
70
Ambient Temperature Range (°C)
Refer to Application Notes
continued on next page
www.recom-power.com
REV: 2/2015
PA-53
RAC48-xx/OF
Series
POWERLINE
AC/DC-Converter
Specifications (typical at 25°C and 230VAC)
Operating Temperature Range
Full Load without derating
-20°C to +50°C
with derating
-20°C to +70°C
Storage Temperature Range
-40°C to +80°C
Operation Humidity
non-condensing
20% - 90% RH
Storage Humidity
10% - 90% RH
Vibration
10-500Hz, 2G, 10 Min. along X, Y and Z
Weight
145g
Dimensions (LxWxH)
101.6 x 50.8 x 30mm
Package Quantity
30pcs / carton
Package Dimensions Carton (LxWxH)
325 x 270 x 220mm
MTBF
(using MIL-HDBK-217F, 25°C)
>450 x 10³ hours
Certifications:
General Safety
Report: E196683
IEC/EN General Safety
Report: PSE103-0658
EMC
UL-60950-1 2nd
IEC/EN-60950-1 2nd
Conducted and Radiated
Report: HA080035-SCCE
EN55022, Class B
Immunity
Report: HA080035-SCCE
EN55024
Report: HA080035-SBFD
FCC, Part 15, Class B
Report: HA080035-SCCE
EN61000-3-2
Harmonics
EN61000-3-3
EN61000-4-2, 3, 4, 5, 6, 8, 11, Critertia A
Emission
ErP
Notes
Note1:
EN61000-6-3
2004/125/EC
Mounting holes A, B must be grounded for EMI (Filter Ground).
Package Style and Pinning
101.6
95.3
3.175
POWER LED
2
50.8
44.5
1
CN1
1
CN2 2
3
4
AC Input Connector (CN1):
Pin#
Terminal
1 AC/N
WST I39606PS-2
or equivalent
2 AC/L
Mating Housing
WST P3-I39606
or equivalent
B
A
3.175
TRIM
VR
F.G.
F.G.
4x
3.3
DC Output Connector (CN2):
Pin#
Terminal
1, 2 V+
WST I39606PS-2
or equivalent
3, 4 V-
Mating Housing
WST P4-I39606
or equivalent
Note: Detail information about the connectors on www.wst.com.tw
30
RAC48/OF
Report: HA080035-SCCE
complies to European Directive for Energy Related Products
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
PA-54
REV: 2/2015
www.recom-power.com