TSM036N03PQ56

TSM036N03PQ56
30V N-Channel MOSFET
PDFN56
Key Parameter Performance
Pin Definition:
1. Source
8. Drain
2. Source
7. Drain
3. Source
6. Drain
4. Gate
5. Drain
Parameter
Value
Unit
VDS
30
V
RDS(on) (max)
VGS = 10V
3.6
VGS = 4.5V
5.5
Qg
24
Ordering Information
mΩ
nC
Block Diagram
Part No.
Package
Packing
TSM036N03PQ56 RLG
PDFN56
2.5kpcs / 13” Reel
Note: “G” denotes for Halogen- and Antimony-free as those which contain
<900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and <1000ppm
antimony compounds
N-Channel MOSFET
Absolute Maximum Ratings (Tc = 25℃ unless otherwise noted)
Parameter
Symbol
Limit
Unit
Drain-Source Voltage
VDS
30
V
Gate-Source Voltage
VGS
±20
V
TC = 25℃
Continuous Drain Current
TC = 100℃
Drain Current-Pulsed (Note 1)
ID
95
60
A
IDM
380
A
EAS
125
mJ
Single Pulse Avalanche Current
IAS
50
A
Maximum Power Dissipation @ TC = 25℃
PD
115
W
TSTG
-55 to +175
℃
TJ
-55 to +175
℃
Symbol
Limit
Unit
Thermal Resistance - Junction to Case
RӨJC
1.3
℃/W
Thermal Resistance - Junction to Ambient
RӨJA
62
℃/W
Single Pulse Avalanche Energy
(Note 2)
Storage Temperature Range
Operating Junction Temperature Range
Thermal Performance
Parameter
1/5
Version: A14
TSM036N03PQ56
30V N-Channel MOSFET
Electrical Specifications (TC = 25℃ unless otherwise noted)
Parameter
Conditions
Symbol
Min
Typ
Max
Unit
BVDSS
30
--
--
V
--
2.7
3.6
--
4.1
5.5
1.2
1.6
2.5
V
--
--
1
µA
--
--
10
µA
nA
Static
Drain-Source Breakdown Voltage
Drain-Source On-State Resistance
Gate Threshold Voltage
VGS = 0V, ID = 250µA
VGS = 10V, ID = 24A
VGS = 4.5V, ID = 12A
VDS = VGS, ID = 250µA
RDS(ON)
VGS(TH)
VDS = 30V, VGS = 0V
Zero Gate Voltage Drain Current
VDS = 24V, VGS = 0V,
TJ = 125℃
IDSS
Gate Body Leakage
VGS = ±20V, VDS = 0V
IGSS
--
--
±100
Qg
--
24
--
Qgs
--
4.2
--
Qgd
--
13
--
Ciss
--
2200
--
Coss
--
280
--
Crss
--
177
--
td(on)
--
12.6
--
tr
--
19.5
--
td(off)
--
42.8
--
tf
--
13.2
--
--
--
1
mΩ
Dynamic
Total Gate Charge
Gate-Source Charge
Gate-Drain Charge
VDS = 15V, ID = 24A,
VGS = 4.5V
Input Capacitance
Output Capacitance
VDS = 25V, VGS = 0V,
f = 1.0MHz
Reverse Transfer Capacitance
nC
pF
Switching
Turn-On Delay Time
Turn-On Rise Time
Turn-Off Delay Time
VGS = 10V, VDS = 15V,
RG = 3.3Ω, ID = 15A
Turn-Off Fall Time
Drain-Source Diode Characteristics and Maximum Rating
Drain-Source Diode Forward
VGS = 0V, IS = 1A
VSD
Voltage
Notes:
1. Repetitive Rating: Pulsed width limited by maximum junction temperature.
2. VDD = 25V, VGS = 10V, L = 0.1mH, IAS = 50A, RG = 25W, Starting TJ = 25℃.
3. Pulse test: pulse width ≤ 300µs, duty cycle ≤ 2%
4. Essentially independent of operating temperature.
2/5
ns
V
Version: A14
TSM036N03PQ56
30V N-Channel MOSFET
Electrical Characteristics Curves
Normalized RDS(on) vs. T J
Normalized On Resistance
ID, Continuous Drain Current (A)
Continuous Drain Current vs. Tc
TC, Case Temperature (℃)
TJ, Junction Temperature (℃)
Gate Charge Waveform
VGS, Gate to Source Voltage (V)
Normalized Gate Threshold Voltage
Normalized Vth vs. TJ
Qg, Gate Charge (nC)
Normalized Transient Impedance
Maximum Safe Operation Area
Normalized Thermal Response
ID, Continuous Drain Current (A)
TJ, Junction Temperature (℃)
VDS, Drain to Source Voltage (V)
Square Wave Pulse Duration (s)
3/5
Version: A14
TSM036N03PQ56
30V N-Channel MOSFET
PDFN56 Mechanical Drawing
Unit: Millimeters
Marking Diagram
Y = Year Code
M = Month Code for Halogen Free Product
(O=Jan, P=Feb, Q=Mar, R=Apl, S=May, T=Jun, U=Jul, V=Aug, W=Sep,
X=Oct, Y=Nov, Z=Dec)
L = Lot Code
4/5
Version: A14
TSM036N03PQ56
30V N-Channel MOSFET
Notice
Specifications of the products displayed herein are subject to change without notice. TSC or anyone on its behalf,
assumes no responsibility or liability for any errors or inaccuracies.
Information contained herein is intended to provide a product description only. No license, express or implied, to
any intellectual property rights is granted by this document. Except as provided in TSC’s terms and conditions of
sale for such products, TSC assumes no liability whatsoever, and disclaims any express or implied warranty,
relating to sale and/or use of TSC products including liability or warranties relating to fitness for a particular purpose,
merchantability, or infringement of any patent, copyright, or other intellectual property right.
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications.
Customers using or selling these products for use in such applications do so at their own risk and agree to fully
indemnify TSC for any damages resulting from such improper use or sale.
5/5
Version: A14