INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS
TOP 100 Series
Order Code
TOP 100-103
Industrial Power Supply
AC-Input
Voltage Range
TOP 100-105
115Vac / 220Vac /
230Vac / 240Vac
TOP 100-112
Autorange
TOP 100-115
90Vac – 132Vac
187Vac – 264Vac
TOP 100-124
TOP 100-148
* Output Voltage
Adjustment Range
Output
Power max.
Output
66 Watt
3.3Vdc / 20.0A
3.3 – 3.5Vdc
5.0Vdc / 20.0A
5.0 – 5.2Vdc
12.0Vdc / 8.3A
12.0 – 13.0Vdc
15.0Vdc / 6.7A
15.0 – 16.0Vdc
24.0Vdc / 4.2A
24.0 – 26.0Vdc
48.0Vdc / 2.1A
48.0 – 52.0Vdc
100 Watt
47 – 63Hz
recommended Circuit
breaker / fuse
6A
(Characteristic C or
slow blow)
* Adjustable by potentiometer with a screwdriver.
Input current:
TOP 100-103
@ Vin=115VAC
@ Vin=230VAC
Power Consumption @ Vin=115VAC @ Vin=230VAC
TOP 100-103
78 Watt typ.
75 Watt typ.
1.5A typ.
0.9A typ.
TOP 100-105
2.1A typ.
1.2A typ.
TOP 100-105
113 Watt typ.
112 Watt typ.
TOP 100-112
TOP 100-115
2.1A typ.
2.1A typ.
1.2A typ.
1.2A typ.
TOP 100-112
TOP 100-115
113 Watt typ.
113 Watt typ.
112 Watt typ.
112 Watt typ.
TOP 100-124
2.1A typ.
1.2A typ.
TOP 100-124
113 Watt typ.
112 Watt typ.
TOP 100-148
2.1A typ.
1.2A typ.
TOP 100-148
113 Watt typ.
112 Watt typ.
Operating temperature range: -25°C – +70°C max
Natural Air Convection Cooling -13°F – +158°F max
Output Power Derating:
above +40°C
above 104°F
above +40°C
above 104°F
above +50°C
above 122°F
Output Power Derating:
93Vac
187Vac
Storage temperature range:
Power Back Immunity
Over Voltage Protection in
single fault condition:
Connections:
1.8%/K (1.2W/°C)
1.0%/°F (0.67W/°F)
2.0%/K (2.0W/°C)
1.11%/°F (1.11W/°F)
2.0%/K (2.0W/°C)
1.11%/°F (1.11W/°F)
Iout max = 50% up to 103Vac
Iout max = 50% up to 207Vac
TOP 100-103
TOP 100-105
TOP 100-112
TOP 100-115
TOP 100-124
TOP 100-148
TOP 100-103
TOP 100-115
Iout max = 100%
Iout max = 100%
AC Input
5Vdc continuous and 6Vdc for 1second max.
6.3Vdc continuous and 7Vdc for 1second max.
16Vdc continuous and 18Vdc for 1second max.
20Vdc continuous and 23Vdc for 1second max.
35Vdc continuous and 40Vdc for 1second max.
63Vdc continuous and 68Vdc for 1second max.
5Vdc / TOP 100-105
6Vdc / TOP 100-112
16Vdc
20Vdc / TOP 100-124
30Vdc / TOP 100-148
60Vdc
PCB Terminals: Molex 41791 Crimp Terminal Housing: Molex 2139
09-50-3031 (voided)
Crimp Terminal: Molex 2478
09-50-3031
08-52-0072
PCB Terminals: Molex 2139 Crimp Terminal Housing: Molex 2139
Crimp Terminal: Molex 2478
26-60-4060
http://www.tracopower.com
Iout max = 100% up to 132Vac
Iout max = 100% up to 264Vac
-25°C – +85°C max
-13°F – +185°F max
DC Output
Case material:
TOP 100-103
TOP 100-103
TOP 100-105
TOP 100-105
all other TOP 100-1xx models
all other TOP 100-1xx models
09-50-3061
08-52-0072
Open Frame, has to be equipped into a fire proofed enclosure.
Rev: 1.3 / 4309
Safety Instructions:
Before installation read these instructions carefully and
completely. This installation instruction cannot account for
every possible condition of installation, operation or
maintenance. Further information can be obtained from
your local distributor’s office or from the product datasheet,
which can be downloaded, from the Internet at
http://tracopower.com/products/top.pdf. You will find
additional information in our Instruction Manual, which can
also be downloaded from the Internet at:
http://www.tracopower.com/products/top_manual.pdf.
The power supplies are constructed in accordance with the
safety requirements of IEC/EN/UL60950-1. They are
approved (BG-mark) in accordance with EN60950-1 and
fulfil the requirements of the Low Voltage Directive (LVD).
They are approved in accordance to UL60950-1
(recognised) by CSA.
Before any installation, maintenance or modification work
ensure that the main switch is switched off and prevented
from being switched on again. Non-observance, touching
of any live components or improper handling of this power
supply can result in death, severe personal injury or
substantial property damage. Proper and safe operation is
dependent on proper storage, handling, installation and
operation.
Compliance with the relevant national regulations (in the
USA, Europe and other countries) must be ensured.
Before operation is started the following conditions must
be ensured:
Connection to mains supply in compliance with national
regulations (VDE0100 and EN50178).
By use of stranded wires, all strands must be fastened
in the terminal blocks. (Potential danger of contact with
the case)
Power supply and mains cables must be sufficiently
fused.
All output wires must be rated for the power supply
output current and must be connected with the correct
polarity.
Sufficient cooling must be ensured.
Installation Instructions:
This power supply is designed for professional indoor
systems. In operation the power supply must not be
accessible. It may be installed and put into service by
qualified personnel only.
To comply with EMC standards the PE terminal should be
connected to the non-fused earth conductor and a ground
plane is mounted underneath of the TOP power supply.
The correct mounting position for optimal cooling
performance must be observed. Do not cover any
ventilation holes. Leave a free space of minimum 50mm
(2in.) above and below the power supply. Observe power
derating.
The internal fuse is not accessible, as it may not be
replaced by the user. If this internal fuse has blown, the
power supply has an internal defect and, for safety
reasons, must be shipped to the local distributor. In case
this internal fuse has to be replaced in the field, replace
only with same type and rating of fuse for continued protection against risk of fire.
Note: While putting on connectors, no mechanical
stress should be applied to the printed circuit board
and its surface mounted components.
This unit contains an automatic input voltage
selection switch. Do not change the input voltage
from 110/115Vac to 230/240Vac without
disconnecting the input supply line first.
Recycling: The unit contains elements that are suitable for
recycling, and components that need special disposal. You
are therefore requested to make sure that the power
supply will be recycled at the end of its service life.
Never work on the power supply if power is supplied!
Risk of electric arcs and electrical shock, which can cause
death, severe personal injury or substantial property
damage.
Warning: Hazardous voltages and components storing a
very substantial amount of energy are present in this
power supply during normal operating conditions. Improper
handling may result in an electric shock or serious burns!
Do not open the power supply until at least 5 minutes
after it has been disconnected from the mains on all
poles.
Only trained personnel may open the power supply.
Do not introduce any objects into the power supply.
The output voltage adjustment potentiometer may only
be actuated using an insulated screwdriver.
Keep away from fire and water
http://www.tracopower.com
Rev: 1.3 / 4309