INSTALLATION INSTRUCTIONS TMT–C Series Industrial Power Supply Output Voltage Output Current max. TMT 15105C 5.0 Vdc 3.000A TMT 15112C 12.0 Vdc 1.250A 15.0 Vdc 1.000A TMT 15124C 24.0 Vdc 0.625A TMT 15212C ±12.0 Vdc ±0.625A TMT 15215C ±15.0 Vdc ±0.500A TMT 30105C 5.0 Vdc 6.00A TMT 30112C 12.0 Vdc 2.50A 15.0 Vdc 2.00A 24.0 Vdc 1.25A ±12.0 Vdc ±1.25A ±15.0 Vdc ±1.00A 5.0 Vdc 9.0A 12.0 Vdc 15.0 Vdc 4.2A 3.4A TMT 50124C 24.0 Vdc 2.3A TMT 50148C 48.0 Vdc 1.15A Order Code AC-Input Voltage Range TMT 15115C 15 Watt TMT 30115C TMT 30124C TMT 30212C Output Power max. 30 Watt 115 – 230Vac (103.5 – 253Vac) TMT 30215C TMT 50105C TMT 50112C TMT 50115C 85 – 264Vac* 47 – 63Hz 120 – 370Vdc* 50 Watt TMT 30252C TMT 30522C 30 Watt TMT 30515C 1A (Characteristic C or slow blow) 2A (Characteristic C or slow blow) 3.15A (Characteristic C or slow blow CH1 5.0 Vdc CH1 3.000A CH2 12.0 Vdc CH2 1.200A CH1 5.0 Vdc CH1 3.000A CH2 12.0 Vdc CH2 1.000A CH3 -12.0 Vdc CH3 0.250A CH1 CH2 CH1 CH2 3.000A 0.500A CH3 -15.0 Vdc CH3 0.500A 5.0 Vdc 15.0 Vdc recommended Circuit breaker or fuse 2A (Characteristic C or slow blow) * Within this AC as well as DC input voltage range the TMT power supplies performs very well but by UL approved is an input voltage range of 115 – 230Vac ±10%. Input current: @ Vin = 115VAC @ Vin = 230VAC Power Consumption @ Vin =115VAC @ Vin =230VAC TMT 15xxxC 0.28A typ. 0.18A typ. TMT 15xxxC 18 Watt typ. 18.5 Watt typ. TMT 30xxxC 0.57A typ. 0.36A typ. TMT 30xxxC 38 Watt typ. 37 Watt typ. TMT 50xxxC 1.0A typ. 0.6A typ. TMT 50xxxC 60 Watt typ. 58 Watt typ. TMT 30xyzC 0.64A typ. 0.39A typ. TMT 30xyzC 39 Watt typ. 39 Watt typ. Surrounding air temperature: -25°C – +50°C max Natural Air Convection Cooling -13°F – +122°F max Output Power Derating: For UL 508 only TMT 15xxxC: above +35°C 3.35%/K above 95°F 3.35%/K TMT 50xxxC: above +30°C 2.5%/K above 86°F 2.5%/K Storage temperature range: -25°C – +85°C max -13°F – +185°F max http://www.tracopower.com TMT 30xxxC: above +25°C 2.0%/K above 77°F 2.0%/K TMT 30xyzC: above +25°C 2.0%/K above 77°F 2.0%/K Rev: 4.0 / 3312 0.128 – 2.08mm2 2 TMT 15105C: 0.325 – 2.08mm Other TMT 15xxxC: 0.128 – 2.08mm2 2 TMT 30105C: 0.823 – 2.08mm TMT 30112C, TMT 30115C: 0.519 – 2.08mm2 2 TMT 30124C, TMT 30212C: 0.205 – 2.08mm TMT 30215C: 0.128 – 2.08mm2 2 TMT 50105C: 1.318 – 2.08mm TMT 50112C, TMT 50115C: 0.823 – 2.08mm2 2 TMT 50124C: 0.519 – 2.08mm TMT 50148C: 0.205 – 2.08mm2 TMT 30252C, TMT 30522C and TMT 30515C: CH1: 0.325-2.08 mm2 2 CH2, CH3: 0.128-2.08 mm Use: Single wire, Stranded wire or Stick connector Wire temperature specification: 60°C minimum (>60°C) Wire material: Copper Input wire: Output wire: Wire recommendation: Connections: Case material: AWG: 22 – 14 AWG: 26 – 14 Without C on the order code: PCB mounting version with pins With C on the order code: Screw type terminal COMBICON. Recommended tightening torque; 5lbf.in (0.565Nm): Other than the output terminal of Models TMT30252C, TMT30522C and TMT30515C. 4.5lbf.in (0.508Nm): The output terminal of Models TMT30252C, TMT30522C and TMT30515C. Non-conductive plastic Safety Instructions: Before installation read these instructions carefully and completely. This installation instruction cannot account for every possible condition of installation, operation or maintenance. Further information can be obtained from your local distributor’s office or from the product data sheet, which can be downloaded, from the Internet at http://tracopower.com/products/tmt.pdf. The power supplies are constructed in accordance with the safety requirements of IEC/EN/UL 60950-1, IEC/EN/UL 60601-1 and UL508. They are approved in accordance with IEC60950-1 (with national deviations tested) and fulfil the requirements of the Low Voltage Directive (LVD). They are UL and cUL approved in accordance to UL60950-1 (recognised) and UL508 (listed) Before any installation, maintenance or modification work ensure that the main switch is switched off and prevented from being switched on again. Non-observance, touching of any live components or improper handling of this power supply can result in death, severe personal injury or substantial property damage. Proper and safe operation is dependent on proper storage, handling, installation and operation. Compliance with the relevant national regulations (in the USA, Europe and other countries) must be ensured. Before operation is started the following conditions must be ensured: Connection to mains supply in compliance with national regulations (VDE0100 and EN50178). By use of stranded wires, all strands must be fastened in the terminal blocks. Power supply and mains cables must be sufficiently fused. Degree of protection II to IEC536. All output wires must be rated for the power supply output current and must be connected with the correct polarity. Sufficient cooling must be ensured. http://www.tracopower.com AWG: 26 – 14 AWG: 22 – 14 AWG: 26 – 14 AWG: 18 – 14 AWG: 20 – 14 AWG: 24 – 14 AWG: 26 – 14 AWG: 16 – 14 AWG: 18 – 14 AWG: 20 – 14 AWG: 24 – 14 Never work on the power supply if power is supplied! Risk of electric arcs and electrical shock, which can cause death, severe personal injury or substantial property damage. Warning: Hazardous voltages and components storing a very substantial amount of energy are present in this power supply during normal operating conditions. However, these are inaccessible. Improper handling may result in an electric shock or serious burns! Do not work on the power supply until at least 5 minutes after it has been disconnected from the mains on all poles. Keep away from fire and water Installation Instructions: This power supply is designed for professional indoor systems. In operation the power supply must not be accessible. It may be installed and put into service by qualified personnel only. The correct mounting position for optimal cooling performance must be observed. Leave a fee space of minimum 50mm (2in.) above and below the power supply. Observe power derating. The external fuse or circuit breaker has to be equipped for continued protection against risk of fire. In case this external fuse has to be replaced in the field, replace only with same type and rating of fuse for continued protection against risk of fire. If this external fuse has blown and keeps blowing after replacing, the power supply may have an internal defect and, for safety reasons, must be shipped to the local distributor. Recycling: The unit contains elements that are suitable for recycling, and components that need special disposal. You are therefore requested to make sure that the power supply will be recycled at the end of its service life. Rev: 4.0 / 3312 INSTRUCTIONS DE MONTAGE Séries TMT–C Code commande Alimentation électrique industrielle Courant de sortie Alimentation AC Puissance de Tension de sortie max. Plage de tension sortie max. Coupe-circuit ou fusible recommandé TMT 15105C 5.0 Vdc 3.000A TMT 15112C 12.0 Vdc 1.250A TMT 15115C 15.0 Vdc 1'000A TMT 15124C 24.0 Vdc 0.625A TMT 15212C ±12.0 Vdc ±0.625A TMT 15215C ±15.0 Vdc ±0.500A TMT 30105C 5.0 Vdc 6.00A TMT 30112C 12.0 Vdc 2.50A TMT 30115C 15.0 Vdc 2.00A 24.0 Vdc 1.25A ±12.0 Vdc ±1.25A ±15.0 Vdc ±1.00A 5.0 Vdc 9.0A 12.0 Vdc 4.2A 3.15A 15.0 Vdc 3.4A 24.0 Vdc 2.1A (caractéristique C ou lent) TMT 30124C TMT 30212C 15 watts 30 watts 115 – 230Vac (103.5 – 253Vac) TMT 30215C TMT 50105C TMT 50112C TMT 50115C 85 – 264Vac* 47 – 63Hz 120 – 370Vdc* 50 watts TMT 50124C TMT 50148C 48.0 Vdc TMT 30252C TMT 30522C 30 Watt TMT 30515C 1A (caractéristique C ou lent) 2A (caractéristique C ou lent) 1.05A CH1 5.0 Vdc CH1 3.000A CH2 12.0 Vdc CH2 1.200A CH1 5.0 Vdc CH1 3.000A CH2 12.0 Vdc CH2 1.000A CH3 -12.0 Vdc CH3 0.250A CH1 5.0 Vdc CH1 3.000A CH2 15.0 Vdc CH2 0.500A CH3 -15.0 Vdc CH3 0.500A 2A (caractéristique C ou lent) * Dans cette plage de tension AC et DC, l’alimentation TMT fonctionne parfaitement, mais, approuvé par UL, la tension d’alimentation est de 115 – 230Vac ±10%. Courant d’alimentation @ Vin = 115VAC @ Vin = 230VAC Puissance absorbée @ Vin =115VAC @ Vin =230VAC TMT 15xxxC Type 0.28A Type 0.18A TMT 15xxxC Type 18 watts Type 18.5 watts TMT 30xxxC Type 0.57A Type 0.36A TMT 30xxxC Type 38 watts Type 37 watts TMT 50xxxC Type 0.87A Type 0.52A TMT 50xxxC Type 60 watts Type 58 watts TMT 30xyzC Type 0.64A Type 0.39A TMT 30xyzC Type 39 watts Type 39 watts Températures de fonctionnement: Refroidissement à circulation naturelle de l’air -25°C – +50°C max -13°F – +122°F max Réduction puissance de sortie: Pur UL508 TMT 15xxxC: plus de +35°C 3.35%/K plus de 95°F 3.35%/K TMT 50xxxC: plus de +30°C 2.5%/K plus de 86°F 2.5%/K Températures de stockage: -25°C – +85°C max -13°F – +185°F max Matériau boîtier: Plastique non conducteur http://www.tracopower.com TMT 30xxxC: plus de +25°C 2.5%/K plus de 77°F 2.5%/K TMT 30xyzC: plus de +25°C 2.5%/K plus de 77°F 2.5%/K Rev: 4.0 / 3312 Fils recommandés: Files d’entrée: 0.128 – 2.08mm2 2 Files sortie: TMT 15105C: 0.325 – 2.08mm Autres TMT 15xxxC: 0.128 – 2.08mm2 2 TMT 30105C: 0.823 – 2.08mm TMT 30112C, TMT 30115C: 0.519 – 2.08mm2 2 TMT 30124C, TMT 30212C: 0.205 – 2.08mm TMT 30215C: 0.128 – 2.08mm2 2 TMT 50105C: 1.318 – 2.08mm TMT 50112C, TMT 50115C: 0.823 – 2.08mm2 2 TMT 50124C: 0.519 – 2.08mm TMT 50148C: 0.205 – 2.08mm2 TMT 30252C, TMT 30522C and TMT 30515C: CH1: 0.325-2.08 mm2 2 CH2, CH3: 0.128-2.08 mm Recourir: Files simple, files toronnée ou Connecteur auto-serrage Température des files: 60°C minimum (>60°C) Matériau du files: Cuivre Connexions: AWG: 22 – 14 AWG: 26 – 14 Sans C sur le code de commande: version de montage PCB avec broches Avec C sur le code de commande: terminal à vis COMBICOM. Couple de serrage recommandé; 5lbf.in (0.585Nm): Autres que le terminal de sortie des modèles TMT30252C, TMT30522C et TMT30515C. 4.5lbf.in (0.508Nm): Le terminal de sortie des modèles TMT30252C, TMT30522C et TMT30515C. Consignes de sécurité : Veuillez lire attentivement et complètement ces instructions avant d’effectuer le montage. Ces instructions de montage ne répondent pas à toutes les conditions de montage, d’opération ou de maintenance. Des informations supplémentaires peuvent être obtenues auprès de votre distributeur local ou sur la feuille de données du produit qui peut être téléchargée du site Internet: http://tracopower.com/products/tmt.pdf. Les alimentations électriques sont construites en conformité avec les directives de sécurité IEC/EN/UL 60950-1, IEC/EN/UL 60601-1 et UL508. Elles sont approuvées conformément à IEC60950-1 (avec divergence nationale testée) et sont conformes aux normes d’installations à basse tension (NIBT). Elles sont approuvées UL et cUL conformément à UL60950-1 (reconnu) et UL508 (inscrit) Avant tout travail de montage, de maintenance ou de modification, assurez-vous que l’interrupteur principal est ouvert et que tout ré-enclenchement est empêché. Un usage inapproprié, toucher une ligne sous tension ou une manipulation non conforme de cette alimentation électrique peut provoquer la mort, des blessures graves ou de gros dommages matériels. Un fonctionnement sûr et conforme dépend d’un bon stockage, d’une bonne manipulation, installation et opération. La conformité avec les directives nationales correspondantes (aux USA, en Europe et autres pays) doit être assurée. Les conditions suivantes doivent être assurées avant opération: Connexion à l’alimentation principale selon les prescriptions nationales (VDE0100 et EN50178). Si des fils toronnés sont utilisés, tous les torons doivent être serrés sur les bornes du terminal. L’alimentation et les câbles électriques principaux doivent être suffisamment protégés par fusible. Classe de protection II selon IEC536. Tous les fils de sortie doivent être dimensionnés pour le courant de sortie de l’alimentation électrique et doivent être connectés avec la bonne polarité. Un refroidissement suffisent doit être assuré. http://www.tracopower.com AWG: 26 – 14 AWG: 22 – 14 AWG: 26 – 14 AWG: 18 – 14 AWG: 20 – 14 AWG: 24 – 14 AWG: 26 – 14 AWG: 16 – 14 AWG: 18 – 14 AWG: 20 – 14 AWG: 24 – 14 Ne jamais travailler sur l’alimentation électrique lorsqu’elle est sous tension ! Il y a risque d’arc électrique et d’électrocution pouvant provoquer la mort, de blessures graves ou de gros dommages matériels. Attention : Dans des conditions d’opération normales cette alimentation électrique comprend des composants pouvant stocker de grandes quantités d’énergie et peut présenter des tensions dangereuses. Ils sont toutefois inaccessibles. Une manipulation non conforme peut provoquer une électrocution ou des brûlures graves. Ne pas travailler sur l’alimentation électrique pendant au moins 5 minutes après que tous les pôles aient été déconnectés de l’alimentation principale Tenir à l’abri du feu et de l’eau. Instructions de montage : Cette alimentation électrique est prévue pour des systèmes professionnels intérieurs. En opération, l’alimentation électrique ne doit pas être accessible. Seul du personnel qualifié peut installer et mettre en service cette alimentation électrique. Il est nécessaire de respecter la bonne position de montage afin d’assurer un refroidissement optimal. Laissez un espace d'au moins 50 mm (2 in.) au-dessus et en dessous de l’alimentation. Observez la réduction de charge. Il est nécessaire d’installer un fusible ou un coupe-circuit externe afin d’assurer une protection continue contre le risque d’incendie. Si ce fusible externe doit être remplacé sur place, remplacez-le par un fusible de même type et de même classe afin d’assurer une protection continue contre le risque d’incendie. Si ce fusible externe à sauté et qu’après remplacement il continue de sauter, l’alimentation électrique peut présenter un défaut interne et, pour des raisons de sécurité, doit être renvoyée chez le distributeur local. Recyclage : L'unité comprend des éléments qui sont susceptibles d’être recyclés et des composants qui nécessitent une élimination spéciale. Vous devez vous assurer que l’alimentation électrique sera recyclée en fin de vie. Rev: 4.0 / 3312