INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS
TOP 100 Series
Order Code**
Industrial Power Supply
Input Voltage Range
TOP 100-103 (C)
Output Power
max.
Output
66 Watt
3.3Vdc / 20.0A
3.3 – 3.5Vdc
5.0Vdc / 20.0A
5.0 – 5.2Vdc
12.0Vdc / 8.3A
12.0 – 13.0Vdc
15.0Vdc / 6.7A
15.0 – 16.0Vdc
24.0Vdc / 4.2A
24.0 – 26.0Vdc
48.0Vdc / 2.1A
48.0 – 52.0Vdc
TOP 100-105 (C)
Rated: 115Vac / 230Vac
TOP 100-112 (C)
50 / 60Hz
Operational:
TOP 100-115 (C)
AC:90-132 / 187-264Vac
TOP 100-124 (C)
47-63Hz
TOP 100-148 (C)
100 Watt
* Adjustable by potentiometer with an insulated screwdriver.
Output Voltage
Adjustment Range*
Recommended Circuit
breaker / fuse
6A
(Characteristic C or
slow blow)
**Option C indicates the unit is in an enclosure
Input current
@ Vin=115VAC
@ Vin=230VAC
TOP 100-103 (C)
1.5A
0.9A
all other TOP 100 (C)
2.1A
1.2A
TOP 100 (Open Frame Units)
TOP100 (C Version)
-25°C - +70°C Max
-25°C - +70°C Max
Operating Temperature Range
(with natural air convection cooling)
Output Power Derating
(in respect to ambient temperature)
Model Type
Start of Derating
TOP 100-103 (C)
+40°C
1.2W/K
TOP 100-105 (C)
+40°C
2.0W/K
TOP 100-112 (C)
+50°C
2.0W/K
TOP 100-115 (C)
+50°C
2.0W/K
TOP 100-124 (C)
+50°C
2.0W/K
TOP 100-148 (C)
+50°C
2.0W/K
Power Derating
Output Power Derating
(in respect to input voltage)
Between 90Vac and 103Vac  3.9%/V
Between 187Vac and 207Vac  1%/V
Storage Temperature Range
-25°C – +85°C max
Power Back Immunity
TOP 100-103 (C)  5Vdc continuous and 6Vdc for 1second max.
TOP 100-105 (C)  6.3Vdc continuous and 7Vdc for 1second max.
TOP 100-112 (C)  16Vdc continuous and 18Vdc for 1second max.
TOP 100-115 (C)  20Vdc continuous and 23Vdc for 1second max.
TOP 100-124 (C)  35Vdc continuous and 40Vdc for 1second max.
TOP 100-148 (C)  63Vdc continuous and 68Vdc for 1second max.
Over Voltage Protection
(in single fault condition)
Connections
TOP 100-103 (C)  5Vdc
TOP 100-105 (C)  6Vdc
TOP 100-112 (C)  16Vdc
TOP 100-115 (C)  20Vdc
TOP 100-124 (C)  30Vdc
TOP 100-148 (C)  60Vdc
Input Connector
PCB Terminals :
Crimp Terminal Housing:
Crimp Terminal:
Molex 41791 – 26-62-4030 (Circuit 2 voided)
Molex 2139 – 09-50-3031
Molex 2478 - 08-52-0072
Output Connector
PCB Terminals:
Crimp Terminal Housing:
Crimp Terminal:
Molex 2139-26-60-4060
Molex 2139-09-50-3061
Molex 2478 – 08-52-0072
PE Connection
Class I operation:
Use enclosure provided (C version unit including Quick Connect Tab)
PE Terminal: 0.187” (4.75mm)
Quick Connect Receptacle
2
1. Type: TE Connectivity 3-520410-2 for wire size: AWG 16-14 (1.25 – 2.00mm )
2
2. Type: TE Connectivity 2-520409-2 for wire size: AWG 22-18 (0.30 – 0.90mm )
Use 4 pillars connected to a metal plane wired to Earth. (Open Frame Units)
Class II operation: no Earth connection required
1.
The following end product enclosures are required: Mechanical, Fire &
Electrical in accordance to applicable safety standards
2.
TOP100C: Material of Base & Cover - Zinc-Plated Steel 1mm
Installation
http://www.tracopower.com
Rev: 1.6 / 3514
Safety Instructions:
 Before installation read these instructions carefully and
completely. This installation instruction cannot account for
every possible condition of installation, operation or
maintenance. Further information can be obtained from
your local distributor’s office or from the product datasheet,
which can be downloaded from our website:
http://www.tracopower.com.
 Before any installation, maintenance or modification work
ensure that the main switch is switched off and prevented
from being switched on again. Non-observance, touching
of any live components or improper handling of this power
supply can result in death, severe personal injury or
substantial property damage. Proper and safe operation is
dependent on proper storage, handling, installation and
operation.
 While applying connections, no mechanical stress should
be applied to the printed circuit board and its surface
mounted components.
 Compliance with the relevant national regulations must be
ensured. Before operation is started the following conditions must be ensured:
 Connection to mains supply in compliance with national
regulations.
 Power supply and mains cables must be sufficiently
fused.
 All output wires must be rated for the power supply
output current and must be connected with the correct
polarity.
 Do not disconnect while circuit is alive.
Installation Instructions
 This power supply is designed for professional indoor
systems. In operation the power supply must not be
accessible. It may be installed and put into service by
qualified personnel only.
 All required connections have to be carried out as
described in the table on the front side.
 By use of stranded wires, all strands must be fastened in
the terminal blocks (potential danger of short circuits).
 Do not cover any ventilation holes. Optimal cooling
performance must be ensured. Observe power derating
(see datasheet).
 The internal fuse(s) may not be replaced by the user. If an
internal fuse has blown, the power supply has most
properly an internal defect and, for safety reasons, must be
shipped to the local distributor.
 Recycling: The unit contains elements that are suitable for
recycling, and components that need special disposal. You
are therefore requested to make sure that the power
supply will be recycled environment friendly at the end of
its service life.
 Never work on the power supply if power is supplied:
Risk of electric arcs and electrical shock, which can cause
death, severe personal injury or substantial property
damage.
 Warning: Hazardous voltages and components storing a
very substantial amount of energy are present in this
power supply during normal operating conditions. Improper
handling may result in an electric shock or serious burns!
 Do not open the power supply
 Do not introduce any objects into the power supply. An
output voltage adjustment potentiometer (if existing)
may only be actuated using an insulated screwdriver.
 Keep away from fire, water and chemicals.