XFDM Data sheet Pre-amplified/5V Excitation/Differential Features . . . . . Applications . Industrial instrumentation . Pressure switch, Pneumatic device Two accuracy ranks, 1.5 FS and 2.5 FS available Volt level output On-chip amplification and temperature compensations Pre-calibration of offset voltage and span Very small surface mountable package, Easy to mount on PCB . Medical device Part number for ordering XFDM - 025KP D S R H Accuracy No mark : 2.5 FS H : 1.5 FS(Contact us about availability) Rated pressure(Pa) Model XFDM Terminal leads direction (See Outline Diagram) R: Pressure type Terminal leads configuration D : Differential S : Surface mount package DW : Differential (Bipolar pressure) Pressure type Differential pressure XFDM Model Package configuration Surface mount package Measurable pressure range (kPa) 100 100 0 25 0 50 0 100 0 200 0 1000 Part number for ordering XFDM-100KPDWSR XFDM-025KPDSR XFDM-050KPDSR XFDM-100KPDSR XFDM-200KPDSR XFDM-001MPDSR Specifications Model/Rated pressure 100KPDW 025KPD 050KPD 100KPD 200KPD Recommended operating conditions Pressure type Differential pressure 100 25 50 100 200 Rated pressure 1.020 0.255 0.510 1.020 2.040 Measurable pressure range 100 100 0 25 0 50 0 100 0 200 Pressure media Non-corrosive gas only Excitation voltage 5.0 0.25 Absolute maximum rating Maximum load pressure Twice of rated pressure Maximum excitation voltage 8 Operating temperature 40 125 Storage temperature 40 125 Operating humidity 30 80 (No dew condensation) Electric performances/characteristics (Excitation voltage Vcc=5.0V constant, Ambient temperature Ta=25 ) Current consumption less than 10 Output impedance less than 10 Source current less than 0.2 Sink current less than 2 Mechanical response time 2 (For the reference) Full scale span voltage 4.5 Offset voltage 1, 2, 3 0.2 0.1125, 0.2 0.0675(H) Full scale span voltage 1, 2, 3 4.7 0.1125, 4.7 0.0675(H) Accuracy 2, 3 2.5, 1.5(H) Note ; 1) Output refers to pressure at pressure port 2. 2) Excluding input voltage error. 3) Please consult us availability when you choose the H models. 1 001MPD Unit 1000 10.20 0 1000 kPa kg/cm2 kPa VDC 1.5times of rated pressure VDC RH mA mA mA msec V V V FS/0 85 XFDM Data sheet Pre-amplified/5V Excitation/Differential Outline dimensions Unit : mm 0.15 XFDM 6 5 Ma Projections 4 Pressure port 2 4 10 Labelled faceplate x 8 3.5 5 6 Pressure port 1 2 2.54 6 0.8 3 1 3 2 1 Recommended footprint for PCB 1 10 M 2.54 ax. 2- 1.2(Holes for projections) Index direction 1.4 0.9 0.6 3.5 1 5.5 0.5 5 (11.5) 2 2.54 2.54 2 1 1 3.3 2.5 17.5 11 14 R0.5 1 Land-pads Zooming up the projections 3.4 11 16.6 (Unit : mm) Index Connection diagram Vcc(DC5V) XFDM Vcc Vout Vout GND Remarks : 1) C1 : Connect 680pF capacitor within 2cm distance from leads. 2) C2 : Connect 0.01 F or more capacitor within 2cm distance from leads. 3) 4 and 5 pins must be No Connection. Open them as floating ones completely, and do NOT connect to other line or each other. C2 C1 GND Transfer Function Vout=Vs (P + ) (Pressure Error Temperature Error Multiplier Vs) Vs=5.0volts Notes ; The output voltage (Vout) is no perfect ratiometric with the power supply voltage. P=Input Pressure(kPa) Model pressure range 025KPG(D) 050KPG(D) 100KPG(D) 100KPGV 100KPGW(DW) 200KPG(D) 001MPGW(D) 115KPA Temperature Error Multiplier Temperature Error Multiplier 3.5 3 2.5 2 0 25kPa 0 50kPa 0 100kPa 0 100kPa 0 +100kPa 0 200kPa 0 +1MPa 15 115kPa.abs 1.5 1 0.5 0 -40 -20 0 20 40 60 80 85 100 125 120 Temperature Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538 2 E-mail : [email protected] 0.036 0.018 0.009 0.009 0.0045 0.0045 0.0009 0.009 0.04 0.04 0.04 0.04 0.49 0.04 0.04 0.095 Pressure Error(kPa) 0.625 1.25 2.5 2.5 5.0 5.0 25 2.5