Inclination Switch NS-10/G

Inclination Switch
NS-10/G
Uses
The inclination switch enables the angle of inclination
of objects such as appliances, machines or motor
vehicles to be monitored and emits an alarm signal
when the angle is exceeded. The alarm threshold
can be set symmetrically by the customer in the
range of ±10°.
Construction / measurement
The sensor consists of an electronic control circuit
and the inclination sensor, secured in a sturdy
aluminium housing. It is connected via a cage clamp
bar and the seal and cable grip are provided by a
PG16 screw mount. The two coding switches for
digital setting of the symmetrical alarm threshold and
the light emitting diodes for the status display are
mounted on the printed circuit board.
Applications
•
•
•
•
Function
The inclination switch is controlled by a
microcontroller which controls not only the sensor
element and switch outputs but also the signal
modulation and measurement calculation. The
analog signals from the inclination cell is transmitted
to the microcontroller for further processing by a
precise 16-bit A/D converter. The microcontroller
compares the threshold reading from the coding
switch with the linearized angle of inclination and
switch on and off the switch outputs accordingly. The
light-emitting diodes indicate the operating
conditions.
Zero point detection
End switch
Overload observation
Threshold switch
Advantage
•
•
•
•
Low vibration sensitivity
1
EMS/ESD protection
High precision
IP 67 housing
Specifications
Min
-10
Single step
0.1
-0.1
-0.25
T=-25...+85°C
load
+0.1
0.05
0.08
+14.4
-25
-40
Typ
0.001
10
16
15
Max
+10
9.9
+0.1
+0.25
50
+140
0.15
2.5
+30
20
+85
+85
67
380
80(W) x 57(D) x 75(L)
Units
°
°
°
°
°
mA
VDC
°
2
mm
VDC
mA
°C
°C
1
2
Norm EN 50121-3-2
by input bridge pin 4 - 5
maximum current load 10 mA
Connection:
Ub
1
GND
2
PEint
3
Ucout
4
Ucin 14.4 ... 140 VDC
Ri
Measurement range
Resolution
Switch threshold adjustable
Precision
Precision (absolute)
2
Switch output
Switch voltage
Switch hysteresis
Terminal strip
PG screw
Voltage supply
Current consumption
Operation temperature
Storage temperature
Protection class IP
Weight
Housing dimensions
Conditions
5
Output left
6
Output right
7
g
mm
HL-Planartechnik GmbH
Hauert 13, 44 227 Dortmund, Tel.: +49 (0) 231/97400, Fax.: +49 (0) 231/974020
Internet: http://www.hlplanar.com E-Mail: [email protected]
Stand:03.03.03
Design:Zn