Picture for Datasheet is missing !!!

www.osram.com/LED-Systems
LINEARlight Flex - LM10A
Data Sheet
Benefits
Picture for
Datasheet
is missing
!!!

Linear separable LED strip on flexible
printed circuit board with self-adhesive back

Low profile

Available in various colors
Applications

Edge-coupling of transparent or diffused
materials

Path illumination, contour accentuation

Illuminated signs
Technical Operating Data
Product
Color
Number of
LEDs
Voltage
[V DC]*
Power
[W]*
Current
[A]*
Radiance
Angle [°]*
Wavelength [nm]
Color Temp [K]*
Lum. Flux
[lm]*
LM10A-W2-865**
LM10A-W3F-854
LM10A-W2-854**
LM10A-W2-847**
LM10A-W3F-840**
LM10A-W3F-830**
LM10A-W3F-827**
LM10A-A1**
LM10A-Y1**
LM10A-T2**
LM10A-B2**
white
white
white
white
white
white
white
red
yellow
green
blue
600
600
600
600
600
600
600
600
600
600
600
24
24
24
24
24
24
24
24
24
24
24
55,0
86,4
55,0
55,0
72,0
72,0
72,0
72,0
72,0
72,0
48,0
2,3
3,6
2,3
2,3
3
3
3
3
3
3
2
120
120
120
120
120
120
120
120
120
120
120
6500 K
5400 K
5400 K
4700 K
4000 K
3000 K
2700 K
617 nm
587 nm
525 nm
470 nm
1290
2000
1290
1290
2350
2350
1850
1620
1290
1200
460
*) All Data are related to the entire module
Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily
correspond to the actual parameters of each single product which could differ from the typical data.
+) Preliminary Data
**) Discontinued
Technical Features
 One reel comes with one LED-band
 Easy mounting by adhesive tape on isolated
 Light emission vertical to the mounting surface
 Entire Module consists of 600 LEDs
 Size of printed circuit board (L x W x H):
8400 mm x 10 mm x 3 mm
 Easy connection with optional
CONNECTsystem LM-xx Flex: Feeder LM-2PIN
Flex, connector LM-CONN-10 Flex and LMCONN-150 Flex.
 Dimmable by pulse width modulation (PWM)
 Size of smallest unit 10 LED
(L x W): 140 mm x 10 mm
 Smallest unit of 10 LEDs can be cut out at
regular intervals without damaging the rest of
the module
LM10A - 10.03.2010
backside
Page 1 of 4
 Only parallel connection allowed
 Up to 50,000 h lifetime
Minimum and Maximum Ratings
Product
Operating Temperature
at Tc-Point [ °C ] *
Storage Temperature
[ °C ] *
Voltage Range
[ V dc ] *
Reverse Voltage
[ V dc ] *
25
LM10A-W2-865**
-30 ... 75
-40 ... 85
23 ... 25
LM10A-W3F-854
-30 ... 75
-40 ... 85
23 ... 25
0
LM10A-W2-854**
-30 ... 75
-40 ... 85
23 ... 25
25
LM10A-W2-847**
-30 ... 75
-40 ... 85
23 ... 25
25
LM10A-W3F-840**
-30 ... 75
-40 ... 85
23 ... 25
0
LM10A-W3F-830**
-30 ... 75
-40 ... 85
23 ... 25
0
LM10A-W3F-827**
-30 ... 75
-40 ... 85
23 ... 25
0
LM10A-A1**
-30 ... 85
-40 ... 85
23 ... 25
25
LM10A-Y1**
-30 ... 85
-40 ... 85
23 ... 25
25
LM10A-T2**
-30 ... 75
-40 ... 85
23 ... 25
25
LM10A-B2**
-30 ... 75
-40 ... 85
23 ... 25
25
*)
Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the LED Module.
Exceeding maximum ratings for operating voltage will cause hazardous overload and will likely destroy the LED Module.
The temperature of the LED module must be measured at the Tc-point according to EN60598-1 in a thermally constant status with a temperature sensor or a temperature
sensitive label. For exact location of the Tc-point see drawing below.
Drawings
Drawing is missing !!!
LM10A - 10.03.2010
Page 2 of 4
Safety Information
 The LED module itself and all its components must not be mechanically stressed.
 Assembly must not damage or destroy conducting paths on the circuit board.
In order to drive OSRAM LED-Modules safely, it is absolutely necessary to operate them with an electronically
stabilised power supply protecting against short circuits, overload and overheating.
To also ease the luminaire/installation approval, electronic control gear for LED or LED modules should carry the CE mark and be
ENEC certified. In Europe the declarations of conformity must include the following standards:
CE: EC 61347-2-13, EN 55015, IEC 61547 and IEC 61000-3-2 - ENEC: 61347-2-13 and IEC/EN 62384.
Also check for the mark of an independent authorized certification institute.
Please see the relevant brochure for more detailed information (see "Related and Further Information")
OSRAM OPTOTRONIC® electronic control gear complies to all relevant standards and guarantees safe operation.
 Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and safety standards.
Only qualified personnel should be allowed to perform installations.
 Observe correct polarity!
Depending on the product incorrect polarity will lead to emission of red or no light. The module can be destroyed! Correct polarity
immediatelly! (see "reverse voltage", page 2)
 Parallel connection is highly recommended as safe electrical operation mode.
Serial connection is not recommended. Unbalanced voltage drop can cause hazardous overload and damage the LED module.
 Please ensure that the power supply is of adequate power to operate the total load.
 When mounting on metallic or otherwise conductive surfaces, there needs to be a electrical isolation at soldering points between
module and the mounting surface.
 The maximum length of a coherently operable unit is different depending upon color:
A1, Y1, T2 (72 W): 4,2 m
B2 (48 W): 6 m
W2 (55 W): 5 m
W3F (86,4W): 3,5m
By two-pole feed in the middle or from both ends the length can be doubled in each case.
 Pay attention to standard ESD precautions when installing the module.
 The module, as manufactured, has no conformal coating and therefore offers no inherent protection against corrosion. The ability to
customize the length of the module by cutting at specifically marked points is a key feature of the product and hence the reason for
no factory installed conformal coating. For these reasons, it is recommended that the user complete all module modifications first
(cutting, wiring) and then apply a conformal coating in the final stages of installation.
 Damage by corrosion will not be honored as a materials defect claim. It is the user´s responsibility to provide suitable protection
against corrosive agents such as moisture and condensation and other harmful elements.
 For applications involving exposure to humidity and dust the module must be protected by a fixture or housing with a suitable
protection class. The module can be protected against condensation water by treatment with an appropriate circuit board grade
conformal coating. The conformal coating should have the following features:
- Optical transparency
- UV-resistance
- thermal expansion matching the thermal expansion of the module 15-30*10^-6 cm/cm/K
- low permeability of steam for all climatic conditions
- resistance against corrosive environment
LM10A - 10.03.2010
Page 3 of 4
Assembly Information
 Connection with soldering wires on unmounted module: Do not pretin the solderpads but pretin the wires and solder for max 4 s at
300 °C. Allow solderpoints to completely cool down before the next soldering. Prevent shear- or peel forces.
 Soldering of wires with the module mounted on a heatsink: Pretin solderpads and wires and solder for max 3 s at 350 °C. Allow
solderpoints to completely cool down before the next soldering. Prevent shear- or peel forces.
 The smallest unit (140 mm- 10 LEDs) can be removed by cutting with scissors between the designated solder pads.
 The mounting of the module is facilitated by means of the double-sided adhesive on the back-surface of the module. Care must be
taken to provide a clean and dry mounting surface, free of oils or silicone coatings as well as dirt particle. The mounting substrate
must have sufficient structural integrity. Take care to completely remove the protective backing. Once the module is appropriately
positioned, press on the module with about 20N/cm² (refer to application techniques of 3M adhesive transfer tapes). In difficult
cases the use of a primer may help.
 The minimum bending radius is 2 cm. The module may be bent over a smaller radius but only in regions of the circuit board
containing no electronic components and such bends should be made once and fixed in position to avoid cyclic fatigue.
 The thermal length expansion coefficient of the modul is 17*10^-6cm/cm/K. When installing in environments with large variations in
temperature (e.g. outdoor applications) and operating length of more than 2 m, the use of metallic mounting surfaces is necessary.
Otherwise it is advisable to use an additional thicker adhesive tape to absorb the stress of any mismatch in expansion coefficients.
Ordering Guide
Productgroup
S-Unit *
Productname
EAN *
LINEARlight Flex
LM10A-W2-865**
4050300887265
LINEARlight Flex
LM10A-W3F-854
4008321214065
8
LINEARlight Flex
LM10A-W2-854**
4050300887289
8
LINEARlight Flex
LM10A-W2-847**
4008321040145
8
LINEARlight Flex
LM10A-W3F-840**
4008321342102
8
LINEARlight Flex
LM10A-W3F-830**
4008321342874
8
LINEARlight Flex
LM10A-W3F-827**
4008321940490
8
LINEARlight Flex
LM10A-A1**
4008321040060
8
LINEARlight Flex
LM10A-Y1**
4050300946030
8
LINEARlight Flex
LM10A-T2**
4008321168832
8
LINEARlight Flex
LM10A-B2**
4008321168818
8
*) EAN: Ordering number per single module
S-Unit: Modules per shipping unit
Note: Typical performance data are subject to change without any further notice, particularly as LED technology evolves.
Sales and Technical Support
OSRAM GmbH
Hellabrunner Strasse 1
D - 81536 München
Germany
www.osram.com
+49 (0)89 6213-0
Sales and technical support is given by the
local OSRAM subsidiaries.
On our world wide homepage all OSRAM
subsidiaries are listed with complete
address and phone numbers.
Related and Further Information
 The new dimension of light
153 S006 GB
www.osram.com/led-systems-downloads
138 W002 GB
 New creativity in lighting design
LED Modules for illuminated signs
 OPTOTRONIC® Technical Guide
 OPTOTRONIC® Data Sheets
 OSRAM LED systems
 Datasheet CONNECTsystem LM-xx Flex
LM10A - 10.03.2010
130 T008 GB www.osram.com/ecg-downloads
http://catalog.myosram.com
www.osram.com/led-systems
www.osram.com/led-systems-downloads
Page 4 of 4
8