EFFECTlight Application notes for EFFECTlight WL01B-X 1. Specification The EFFECTlight is a module with a very narrow beam for effect lighting of facades, walls or collumns. The modules are adjusted to the electronic ballasts and control gear OSRAM OPTOTRONIC ®. Up to 14 modules can be connected in series. The modules can also be combined with secondary optical elements. EFFECTlight EFFECTlight in application 2. Technical Details EFFECTlight WL01B module Note: Please read the datasheet carefully. You can find detailed information about significant security and mounting notices. For electrical installations of the ballasts please refer to the OPTOTRONIC® “Technical handbook“ (download at www.osram.de/service_corner) and the datasheets of the corresponding ballasts and control gear (see also page 3). Product datasheet Page 1 of 6 Version: May 2006 EFFECTlight Application notes for EFFECTlight WL01B-X 3. Electrical connection Polarity lock Electrical connection with the OSRAM CONNECTsystem LM-2x is possible on both sides of the module. A polarity lock in the electrical connection secures that a polarity reversal is not possible. Additionally the polarity is marked. Please refer to the datasheet LM-2x. Polarity lock with electrical connection Feeder LM-2PIN: The one side open electrical Feeder LM-2PIN is used for connection with the corresponding ballasts. Feeder LM-2PIN Board-to-board connector LM-2CONN: The modules can be connected in a row without gaps. Polarity locked board to board connection system LM-2CONN Please note: Due to the polarity lock system the feeder and connector can only be pinned in one way. If necessary flip one of the modules according to the polarity. Do not use force to connect with boards. When connected board to board a little clearence is normal. Two modules connected Page 2 of 6 Version: May 2006 EFFECTlight Application notes for EFFECTlight WL01B-X Flexible connector (5 cm) LM-2CONN-50: Using the flexible connector it is possible to mount the EFFECTlight modules in edges or across cants on facades, walls or collumns. Flexible connection LM-2CONN-50 4. Power supply Single power: EFFECTlight modules are adjusted to the electronic ballasts OSRAM OPTOTRONIC ®. Using the OSRAM electronic control gear OSRAM OT DIM they can be dimmed with pulse width modulation (PWM). Only parallel connection allows a secure operation of the modules. Please observe that the right polarity is used (+ +, - -). Series connection is not recommended. Unbalanced voltage drops can result in overloads in single modules. red yellow verde blue 1,5 W 1,5 W 1,1 W 1,1 W Number of possible modules: OT 6/100-120/24 4 4 5 5 OT 6/200-240/24 4 4 5 5 OT 8/200-240/24 5 5 7 7 OT 20/120-240/24 S 13 13 18* 18* OT 20/230-240/24 13 13 18* 18* OT 75/120-277/24 E 50* 50* 68* 68* OT 75/220-240/24 50* 50* 68* 68* * Due to the voltage drop and load rating of the circuit board maximum 14 modules can be connected. Page 3 of 6 Version: May 2006 EFFECTlight Application notes for EFFECTlight WL01B-X 5. Mounting Sample mounting EFFECTlight modules can be mounted in plastic or metal C or L-shaped profiles. We recommend e. g. the following manufacturers: Sahlberg - www.sahlberg.biz Murtfeldt - www.murtfeldt.de Stegherr - www.stegherr.com EFFECTlight modules can be mounted in a Cshaped profile or with mounting brackets locking in the mounting noth on the module. Additionally the modules can be glued in a L-shaped profile. The connection of the modules can either be soldered (0,5mm2) or connected with the available CONNECTsystem accessories LM-2PIN, LM2CONN und LM-2CONN-50 (see also 3). It is recommended to verify the projection and adjust when necessary before locating the modules. 6. Outdoor application Important notice EFFECTlight modules are shipped with no anticorrosive. When using in outdoor applications they must be protected against moisture and condensation water. LM-2x are for indoor use only. Page 4 of 6 Version: May 2006 EFFECTlight Application notes for EFFECTlight WL01B-X 7. Thermo- management and lifetime Temperature range: In operation: Tc -30 to 65°C Storage: Tc -40 to 85°C A1: > 50thrs (Tc=40°C) 50thrs (Tc=75°C) Y1: > 50thrs (Tc=40°C) 50thrs (Tc=75°C) V1: in preperation B2: in preperation The position of the Tc spot used to measure the temperature on the LED module is shown in the datasheet. Additional cooling surfaces are not necessary. Please refer to the OSRAM application note „Lifetime of LED modules“. 5. 8. Security notes All components on the circuit board must not be mechanical stressed. The conductors on the circuit boards must not be interrupted or damaged. Please do not operate the LED modules under water. 9. Literature Further literature and application notes: • Datasheet EFFECTlight WL01B • Datasheet CONNECTsystem LM-2x • OPTOTRONIC® “Technical handbook“ • Application notes „Lifetime of LED modules“ (OSRAM LiveLink) • www.osram.com/products/led-systems/ • www.osram.com/products/electronical/optotronic • www.osram.com/service_corner/ Page 5 of 6 Version: May 2006