CD - Power Entry Modules with Line Filter

CD
Power Entry Modules with Line Filter
www.schurter.com/pg06
Medical version
IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole (5x20 mm or 6.3x32 mm), Line Switch 1- or 2pole, Voltage Selector (Step)
Fuse drawer must be ordered separately (see
accessories).
C14
70° C
Description
Characteristics
Approvals
References
-Panel Mount:
Screw-on mounting from front side
-5 Functions:
Appliance Inlet, Line Switch, Fuseholder with interchangeable fuse drawer for Fuse-links 5 x 20 mm or 6.3 x 32 mm, with or without voltage
selector (step switch), Line filter in standard and medical version
-Quick connect terminals 4.8 x 0.8 mm
-All single elements are already wired
-The fuse drawer “Fingergrip” can be removed by hand
For added safety "Extra-Safe" fuse drawers are available
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuse drawer can only be opened with the aid of a tool
The fuseholder is accessible from the equipment front
-Qualified for use in equipment according IEC/EN 60950
Alternative: version without line filter KD -VDE Certificate Number: 40004665 (FKSO, FKSP, FKSU, FKSV)
-UL File Number: E72928 (FKSO, FKSP, FKSU, FKSV)
Weblinks
pdf, html, General Product Information, Approvals, RoHS, CHINA-RoHS,
Mating Connectors, e-Store, SCHURTER-Stock-Check, DistributorStock-Check, Accessories
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Quick connect terminals 4.8 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
Fuseholder
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Voltage Selectors
Line Filter
MTBF
EMC Products
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 or 6.3 x 32 mm
5 x 20: 2.5 W (1 pole)/ 2 W (2-pole) per
pole
6.3 x 32: 3.15 W (1 pole)/ 2.5 W (2-pole)
per pole
Admissible power acceptance at higher ambient temperature see derating
curves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical details
optional, step, 2-4 digits
IEC 60939, IEC 60601‑1, UL 1283, UL
544, EN 133 200, CSA C22.2 no. 8
Technical details
> 1'200'000 h acc. to MIL-HB-217 F
CD
Power Entry Modules with Line Filter
www.schurter.com/pg06
Medical version
Dimensions
CD
69 mm
30
55
M3/ø 3.6
2
ø 3.2
R6
+0.3
67.5 0
66.2
83.5
75.5
4.8x0.8
75.5 ±0.15
230
ø 6.3x90˚
R 4.5
0
R 3 -0.2
56
R 3.1
2.8
28.5
69
27.2
+0.3
0
Technical Data of Filter-Components
Rated Current
[A]
Filter-Type
Inductances
L [mH]
Capacitance
CX [nF]
Capacitance
CY [nF]
R [MΩ]
2 x 10
68
-
1
1
Medical Version (M5)
2
Medical Version (M5)
2x4
68
-
1
4
Medical Version (M5)
2 x 1.5
68
-
1
6
Medical Version (M5)
2 x 0.8
68
-
1
10
Medical Version (M5)
2 x 0.3
68
-
1
Diagrams
Medical version
with voltage selector
1) Line
2) Load
x) External connection to be made by the
customer
2.0
I = 1.0 In
1.5
I = 0.7 In
I = < < In
1.0
0.5
0.0
0
20
40
60
80
Ambient air temperature Ta °C
100
Fuses
6.3 x 32 mm (1-pole)
Fuses
6.3 x 32 mm (2-pole, per pole)
3.15
2.0
1.5
I = 1.0 In
I = 0.7 In
1.0
I = < < In
0.5
0.0
0
20
40
60
80
Ambient air temperature Ta °C
100
2.5
I = 1.0 In
2.0
I = 0.7 In
1.5
I = < < In
1.0
0.5
0.0
0
20
40
60
80
Ambient air temperature Ta °C
EMC Products
100
Admissible power acceptance in Watt per pole
Admissible power acceptance in Watt
2.5
Admissible power acceptance in Watt per pole
Fuses
5 x 20 mm (2-pole, per pole)
Admissible power acceptance in Watt
Derating Curves
Fuses
5 x 20 mm (1-pole)
2.5
2.0
I = 1.0 In
1.5
I = 0.7 In
I = << In
1.0
0.5
0.0
0
20
40
60
80
Ambient air temperature Ta °C
100
CD
Power Entry Modules with Line Filter
www.schurter.com/pg06
Attenuation Loss
Medical version
- - - - differential mode _____ common mode
Medical version (M5)
1A
2A
4A
6A
Filter-Type
Fuseholder
Line Switch
Voltage Selectors
Order Number
10 A
Variants
Type
Rated Current
[A]
CD
1
Medical Version (M5)
2-pole
2-pole
2-4 digits
CDG4.4101.151
CD
2
Medical Version (M5)
2-pole
2-pole
2-4 digits
CDA4.4101.151
CD
4
Medical Version (M5)
2-pole
2-pole
2-4 digits
CDC4.4101.151
CD
6
Medical Version (M5)
2-pole
2-pole
2-4 digits
CDE4.4101.151
CD
10
Medical Version (M5)
2-pole
2-pole
2-4 digits
CDL4.4101.151
Packaging unit 10 Pcs Required Accessory
Description
Fusedrawer 3
Fusedrawer for Fuse Links 5x20mm resp. 6.3x32mm
Fingergrip, 5 x 20, 2-pole, Voltage Selectors
4303.2014.00
Fingergrip, 5 x 20, 2-pole, Voltage Selectors, 100, 120, 220, 240
4303.2014.01
Fingergrip, 5 x 20, 2-pole, Voltage Selectors, 110, 150, 220
4303.2014.02
Fingergrip, 5 x 20, 2-pole, Voltage Selectors, 110, 220
4303.2014.03
...
EMC Products
CD
Medical version
Power Entry Modules with Line Filter
www.schurter.com/pg06
Accessories
Assorted Covers
Rear Cover
0859.0077
Wire Harness
Wire harness for SCHURTER products
Cord retaining kits
Cord retaining strain relief
Flat head, A
4700.0001
Mating Outlets/Connectors
Category / Description
Appliance OutletOverview complete
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal
4787
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal
4788
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal
5091
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal
5092
Appliance Outletfurther types toCD
ConnectorOverview complete
IEC Connector C15, Rewireable, Straight
0101
IEC Connector C15A, Rewireable, Straight
0102
IEC Connector C15A, Rewireable, Straight
0102-G
IEC Connector C15A, Rewireable, Angled
0112
IEC Connector C13, Rewireable, Angled
4012
Connectorfurther types toCD
...
Power CordOverview complete
Power Cord with IEC Connector C13, Angled
0311
Power Cord with IEC Connector C13, Angled
3011
Power Cord with IEC Connector C13, Angled
3012
Power Cord with IEC Connector C13, Angled
3013
Power Cord with IEC Connector C13
3020
Power Cordfurther types toCD
...
The
specifications,
descriptions and illustrations indicated in this document are based on
EMC
Products