CE Power Entry Modules with Line Filter www.schurter.com/PG06 IEC Appliance Inlet C14 with Filter, Fuseholder 1-or 2-pole (5 x 20 mm or 6.3x32 mm, with or without voltage selector (series-parallel) Standard- or Medical-Filter Fuse drawer and voltage selector insert must be ordered separately. C14 70° C Description -Panel Mount: Screw-on mounting from front side -4 Functions: Appliance Inlet, Fuseholder with interchangeable fuse drawer for Fuselinks 5x20 mm or 6.3x32 mm 1‑ or 2‑pole, Voltage Selector (seriesparallel), Line filter in standard and medical version -Quick connect terminals 4.8 x 0.8 mm Approvals -VDE Certificate Number: 40004665 (FKA, FKB) -UL File Number: E72928 (FKA, FKB) Characteristics -All single elements are already partially wired -For added safety "Extra-Safe" fuse drawers are available -Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 References Alternative: version without line filter KE Alternative: Standard version Weblinks pdf-datasheet, html-datasheet, General Product Information, Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, REACH, Mating Connectors, e-Shop, SCHURTER-Stock-Check, Distributor-StockCheck, CAD-Drawings, Accessories, Detailed request for product Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Allowable Operation Temp. Climatic Category Degree of Protection Protection Class Terminal Panel Thickness s Material: Housing 1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 °C to 85 °C 25/085/21 acc. to IEC 60068-1 from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 4.8 x 0.8 mm Screw: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-Inlet/-Outlet Fuseholder Rated Power Acceptance @ Ta 23 °C Power Acceptance @ Ta > 23°C Voltage Selector Line Filter MTBF C14 acc. to IEC 60320, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I 1 or 2 pole, Shocksafe category PC2 acc. to IEC 60127-6, for fuse-links 5 x 20 or 6.3 x 32 mm 5 x 20: 2.5 W (1 pole)/ 2 W (2-pole) per pole 6.3 x 32: 3.15 W (1 pole)/ 2.5 W (2-pole) per pole Admissible power acceptance at higher ambient temperature see derating curves series-parallel, 4, 3 or 2 switch positions or usable as 2-pole change-over switch Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details > 1'400'000 h acc. to MIL-HB-217 F Connectors 1 CE Power Entry Modules with Line Filter www.schurter.com/PG06 Dimension 55 30 M3/ø 3.6 2 ø 3.2 R6 4.8x0.8 61.5 ±0.15 +0.3 0 53.5 52.2 61.5 69.5 230 ø 6.3x90˚ R 4.5 0 R 3 -0.2 4.8x0.8 56 R 3.1 2.8 28.5 69 27.2 +0.3 0 Technical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ] 1 Standard Version 2 x 10 68 2.2 - 2 Standard Version 2x4 68 2.2 - 4 Standard Version 2 x 1.5 68 2.2 - 6 Standard Version 2 x 0.8 68 2.2 - 10 Standard Version 2 x 0.3 68 2.2 - 1 Medical Version (M5) 2 x 10 68 - 1 2 Medical Version (M5) 2x4 68 - 1 4 Medical Version (M5) 2 x 1.5 68 - 1 1 6 Medical Version (M5) 2 x 0.8 68 - 10 Medical Version (M5) 2 x 0.3 68 - 1 2 Medical Version (M80) 2x4 68 0.47 1 Diagrams Standard version Medical version (M5) 3 L L1 1) F1 Cy PE Cx L2 N X) Cy PE’ F2 8 4 X) 1) Line 2) Load x) External connection to be made by the customer 2 5 Voltage 6 Selector 7 Connectors 2) L1 1) PE 9 10 3 L N Cx X) F1 PE’ R L2 F2 1) Line 2) Load x) External connection to be made by the customer 5 Voltage 6 Selector 7 8 4 X) 9 10 2) CE Power Entry Modules with Line Filter www.schurter.com/PG06 Derating Curves 2.0 I = 1.0 In 1.5 I = 0.7 In I = << In 1.0 0.5 0.0 0 20 40 60 80 100 Ambient air temperature Ta °C 2.0 1.5 I = 1.0 In I = 0.7 In 1.0 I = << In 0.5 0.0 0 20 40 60 80 100 Ambient air temperature Ta °C Fuses 6.3 x 32 mm (2-pole, per pole) 3.15 2.5 I = 1.0 In 2.0 I = 0.7 In 1.5 I = << In 1.0 0.5 0.0 0 20 40 60 80 100 Admissible power acceptance in Watt 2.5 Fuses 6.3 x 32 mm (1-pole) Admissible power acceptance in Watt Fuses 5 x 20 mm (2-pole, per pole) Admissible power acceptance in Watt Admissible power acceptance in Watt Fuses 5 x 20 mm (1-pole) Ambient air temperature Ta °C Attenuation Loss 2.5 2.0 I = 1.0 In 1.5 I = 0.7 In I = << In 1.0 0.5 0.0 0 20 40 60 80 100 Ambient air temperature Ta °C - - - - differential mode _____ common mode Standard version 1A 2A 4A 6A 2A 4A 6A 10 A Medical version (M5) 1A 10 A Connectors 3 CE Power Entry Modules with Line Filter www.schurter.com/PG06 All Variants Rated Current [A] Filter-Type Fuseholder Order Number 1 Standard Version 1-pole CE16.5100.151 2 Standard Version 1-pole CE26.5100.151 4 Standard Version 1-pole CE36.5100.151 6 Standard Version 1-pole CE46.5100.151 10 Standard Version 1-pole CE66.5100.151 1 Standard Version 2-pole CE10.6100.151 2 Standard Version 2-pole CE20.6100.151 4 Standard Version 2-pole CE30.6100.151 █ 6 Standard Version 2-pole CE40.6100.151 █ 10 Standard Version 2-pole CE60.6100.151 █ 1 Medical Version (M5) 2-pole CEG0.6100.151 2 Medical Version (M5) 2-pole CEA0.6100.151 4 Medical Version (M5) 2-pole CEC0.6100.151 6 Medical Version (M5) 2-pole CEE0.6100.151 █ 10 Medical Version (M5) 2-pole CEL0.6100.151 █ █ Most Popular. Availability for all products can be searched real-time:http://www.schurter.com/en/Stock-Check/ Stock-Check-SCHURTER Suffix ".21" corresponds to the version with V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Packaging unit 10 Pcs Required Accessory Description Voltage Selectors Insert 1 Voltage Selector Insert to KE, CE, KG, CG 3 or 4 switch positions 4305.0048.01 3, 3 or 4 switch positions, 130, 110, 240, 220 4305.0048.02 2, 2 switch positions, 110, 220 4305.0048.03 ... Fusedrawer 1 Fusedrawer for Fuse Links 5x20 mm resp. 6.3x32 mm 5 x 20, 2-pole 4305.0001 5 x 20, 1-pole 4305.0006 6.3 x 32, 2-pole 4305.0011 6.3 x 32, 1-pole 4305.0016 ... Jumper Wire 1 Connection with Stranded Cable Type A, 70 mm 0881.0074 Type A, 100 mm 0881.0075 Type B, 70 mm 0881.0076 Type B, 100 mm 0881.0077 4 4305.0048.00 1, 3 or 4 switch positions, 100, 120, 220, 240 Connectors CE Power Entry Modules with Line Filter www.schurter.com/PG06 Accessories Assorted Covers Rear Cover 0859.0108 Cord retaining kits Cord retaining strain relief Flat head, A 4700.0001 Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal 4787 IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 Appliance Outlet further types to CE Connector Overview complete 4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4782 4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4022 4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4785 4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06 4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4012 Connector further types to CE ... Mating Outlets/Connectors shuttered Power Cord Overview complete VAC17KS, North America, 2.0 m, Connector C17, cord end: 6051.2801 VAC17KS, Europlug, 2.0 m, Connector IEC C17, cord end: 6051.2803 VAC17KS, Europlug, 2.0 m, Connector IEC C17, cord end: 6051.2813 VAC13KS, Overview, diverse Connector IEC C13, cord end: VAC13KS Power Cord further types to CE 24.08.2015 The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. Connectors 5