VI-RAM VE-RAM data sheet

Data Sheet
VI-RAMTM/VE-RAM (RoHS Compliant)
Ripple Attenuator Modules
Features
• RoHS compliant (VE versions)
• Reduces output ripple to <3 mV pp
• Compatible with any VI-200/VI-J00-
based product: 5 to 50 Vdc output
Full attenuation up to 20 A
No adjustments required
93 – 99% efficiency
Converter sense, trim, overvoltage
and overcurrent retained
• Size: 2.28" x 2.4" x 0.5"
(57,9 x 61,0 x 12,7 mm)
• CE Marked
•
•
•
•
Product Highlights
Ripple attenuator modules may be connected
to VI-200 or VI-J00 converters, FlatPACs,
ComPACs or MegaModules, with output
voltages from 5 – 50 V, to limit output noise
to less than 3 mV peak-to-peak at loads up
to 20 A. Combining active and passive
filtering, the VI-RAM attenuates both
low frequency input power source
fundamental and harmonics, as well as high
frequency switching components in the
frequency range of DC to 20 MHz, while
exhibiting efficiencies of 93-99%. No
adjustments are required, and remote sense
and output voltage trim features are retained.
A member of Vicor’s high-power density,
high performance, component-level
power building blocks, the VI-RAM offers
the power systems architect a single,
flexible, component-level solution to almost
any “clean power” problem. At the same
time, the VI-RAM eliminates the space,
efficiency, and weight penalties associated
with linear power sources, and the stability,
efficiency, and adjustment penalties
associated with external “add on” filters for
conventional switchers.
VI-RAM Specifications
(typical at TBP = 25°C, nominal line, 75% load unless otherwise specified)
Parameter
Output Noise & Ripple
VI-200
VI-J00
Min.
Input Voltage Range
Output Voltage Deviation
5 Vdc
Typ.
Max.
3 mV pp
10 mV pp
10 A
20 A
30 A
Overload Current
DC Voltage Drop
Weight
E,C-Grade
I,M-Grade
From 10% of full rated
output current of the
source converter to full load
50 Vdc
0.5%
Full Load Current
Isolation
Size
Remarks
From the output voltage of
the VI-200 source to which
the VI-RAM will be connected
E1, C1, I1 or M1
E2, C2, I2 or M2
At max. operating baseplate
temperature
Up to 10 A
Up to 20 A
Up to 30 A (overload)
0.34
0.41
0.34
0.44
0.34
0.75
Dissipation = (DC voltage drop) x (Load current + 15 mA)
500VRMS
Input/Output to baseplate
2.28" x 2.4" x 0.5"
SlimMod and FinMod
(57,9 x 61,0 x 12,7)
packages available
3.6(102)
3.0(85)
3.7(105)
3.8(107)
Ounces(Grams)
Electrical Considerations
Transient Response and Dynamic Range: Full rated noise attenuation will be maintained at
the VI-RAM output for step load changes up to 10% of the rated output current of the source
converter, with the VI-RAM exhibiting an underdamped output excursion of less than 10 mV pp.
Some degradation in noise attenuation during the transient response period following the step may be
exhibited for larger load changes. Adding output capacitance to the VI-RAM will improve the
rejection over a larger dynamic range.
Sense Connection: Sense -In and Sense -Out connections are provided on the VI-RAM. Sense -In
connections must be connected to the corresponding sense connections on the Vicor converter. Sense -Out
pins on the VI-RAM must be connected between the VI-RAM power-output pins and the point of load.
Output Load Characteristics: When used in combination with Vicor DC-DC converters, and
with sense leads connected, the VI-RAM will be stable for any non-inductive load.
DC Voltage Drop: Below full load, the input to output DC Voltage Drop is controlled to be an
essentially constant voltage which appears between the –IN and –OUT terminals. In overload the DC
voltage drop will rise as current increases. A few tens of millivolts appears between the +IN and
+OUT terminals. Care should be taken not to connect IN and OUT terminals (i.e. through scope probe
returns, grounds, etc.), as attenuation will be adversely affected.
Product Grade Specifications
Parameter (Up to 10 A)
VI-RAM-E1
(Up to 20 A)
VI-RAM-E2
Storage Temp.
-20°C to +105°C
Operating Temp.
-10°C to +100°
(Baseplate)
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
VI-RAM-C1
VI-RAM-C2
-40°C to +105°C
VI-RAM-I1
VI-RAM-I2
-55°C to +105°C
VI-RAM-M1
VI-RAM-M2
-65°C to +105°C
-25°C to +100°C
-40°C to +100°C
-55°C to +100°C
VI-RAM Ripple Attenuator Modules
Set your site on VICOR at vicorpower.com
Rev.1.6
Page 1 of 4
Comparison of Input to Output Ripple (typical)
Attenuation vs. Frequency (typical)
25 db
30 db
Attenuation
35 db
Input to the converter 10 V/cm
40 db
45 db
50 db
55 db
60 db
10 Hz
100 Hz
1 KHz
10 KHz
100 KHz
1 MHz
10 MHz
Frequency
Output from the RAM 20 mV/cm
Recommended Connection Diagram
.01µF
.01µF
+
L1
+ In
Gate In
C1
+ S In
+S
VI-200
Gate Out
–
+ In
+ Out
– In
Trim
–S
– Out
+ Out
+ S Out
VI-RAM
+
220µF
– S In
– In
0.22µF
N/C
Load
– S Out
– Out
.01µF
.01µF
For important application information please refer to the Design Guide and Applications Manual for VI-200 and VI-J00 Family.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
VI-RAM Ripple Attenuator Modules
Set your site on VICOR at vicorpower.com
Rev.1.6
Page 2 of 4
MECHANICAL DRAWING
2.28
(57,9)
0.49
(12,4)
0.30±0.015
(7,6)±(0,38)
Standard
0.080 Dia (2) places
Solder plate
over copper alloy
1.30
(33,0)
0.65
(16,5)
RoHS
0.080 Dia (2) places
Matte tin over copper
alloy
Pin #
4
9
3
8
2.10
(53,4)
7
VI-RAM
2
6
1
5
FULL R
.15
(3,8)
.15
(3,8)
1.90
(48,3)
.70
.40 (17,8)
(10,2)
1.40
1.00 (35,6)
(25,4)
.35± .015
(8,9)±(0,38)
Function
1
+In
2
+Sense In
3
–Sense In
4
–In
5
+Out
6
+Sense
7
NC
8
–Sense
9
–Out
Standard
RoHS
0.040 (1,0) Dia (7) places
Solder plate
over copper alloy
0.040 (1,0) Dia (7) places
Matte tin over copper
alloy
Product ID
this surface
2.40
(61,0)
.30
(7,6) Min.
0.22
(5,6) Min.
.50
(12,7)
1.75 Max.
(44,4)
+.030 (0,76)
-.000 (0,00)
.01
.12
(3,0)
Aluminum Base
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
VI-RAM Ripple Attenuator Modules
Set your site on VICOR at vicorpower.com
Rev.1.6
Page 3 of 4
Warranty
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal
use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or
maintenance. Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original
purchaser only.
EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
Vicor will repair or replace defective products in accordance with its own best judgement. For service under this warranty, the
buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products
returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the
product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty.
Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is
assumed for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve
reliability, function, or design. Vicor does not assume any liability arising out of the application or use of any product or
circuit; neither does it convey any license under its patent rights nor the rights of others. Vicor general policy does not
recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten life or
injury. Per Vicor Terms and Conditions of Sale, the user of Vicor components in life support applications assumes all risks of
such use and indemnifies Vicor against all damages.
Vicor’s comprehensive line of power solutions includes high density AC-DC
and DC-DC modules and accessory components, fully configurable AC-DC
and DC-DC power supplies, and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its
use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunction
could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available upon request.
Specifications are subject to change without notice.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent
applications) relating to the products described in this data sheet. Interested parties should contact Vicor's Intellectual
Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: [email protected]
Technical Support: [email protected]
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
VI-RAM Ripple Attenuator Modules
Set your site on VICOR at .vicorpower.com
Rev. 1.6
11/08