MI-RAM data sheet

Data Sheet
MI-RAM™
Ripple Attenuator Modules
Features
•
•
•
•
•
•
•
•
Reduces output PARD to ≤10 mV pp
Full attenuation up to 20 A load
No adjustments required
Compatible with all MI-Family
converters from 5 to 50 Vdc output
Efficiency: 93% – 99%
Converter sense, trim, OVP & OCP
retained
MIL-STD-810 environments
Size: 2.28” x 2.4” x 0.5”
(57,9 x 61,0 x 12,7 mm)
Product Highlights
The MI-RAM is designed for applications
where extremely low noise outputs are
required. When used with any Vicor
MI-Family DC-DC converter, the MI-RAM
reduces both line frequency related ripple and
switching noise to less than or equal to 10
mV p-p, DC to 20 MHz.
The combination of the MI-RAM with an
MI-Family converter provides the output
noise performance of a linear supply at a
power density in excess of 15 W/in3.
All of the features of the MI-Family converter
remain available while using the MI-RAM,
including output voltage trimming, OVP and
OTP (MI-200 only), current limiting, remote
sense, and output inhibit.
Full encapsulation in a low profile package
enables the MI-RAM to meet
MIL-STD-810 environmental testing
requirements.
MI-RAM Specifications
(typical at TBP = 25°C, nominal line, 75% load unless otherwise specified)
Parameter
Min.
Typ.
2.0
6.0
Max.
Units
3.0
mV
pp
Output noise and ripple
10.0
mV pp
Input voltage range
5.0
50
Vdc
Output voltage accuracy
99.5
100.5
%
10
A
Full load current
20
A
DC voltage drop
0.34
0.38
Dissipation = (DC voltage drop x load current) + (Vin x 15 mA)
Isolation
250
Vrms
3.6
3.7
3.8
ounces
Weight
102
105
107
grams
Notes
MI-200; 10% to 100% load
MI-J00; 10% to 100% load
Of MI source converter
MI-RAM-I1 and MI-RAM-M1
MI-RAM-I2 and MI-RAM-M2
10% to full load
Input / output to baseplate
Electrical Considerations
Transient Response and Dynamic Range: Full rated noise attenuation will be maintained at
the MI-RAM output for step load changes up to 10% of the rated output current of the source
converter, with the MI-RAM exhibiting an underdamped output excursion of less than 10 mV pp.
Some degradation in noise attenuation during the transient response period following the step may be
exhibited for larger load changes. Adding output capacitance to the MI-RAM will improve the
rejection over a larger dynamic range.
Sense Connection: Sense-in and sense-out connections are provided on the MI-RAM. Sense-in
connections must be connected to the corresponding sense connections on the Vicor converter.
Sense-out pins on the MI-RAM must be connected between the MI-RAM power-output pins, and the
point of load.
Output Load Characteristics: When used in combination with Vicor DC-DC converters, and
with sense leads connected, the MI-RAM will be stable for any non-inductive load.
DC Voltage Drop: Below full load, the input to output DC Voltage Drop is controlled to be an
Packaging Options
Standard: Slotted baseplate
SlimMod: Flangeless baseplate, option suffix: - S
Example: MI - RAM - M1 - S
FinMod: Finned heat sink, option suffix:
- F1, - F2, -F3 or -F4
Examples:
MI - RAM - M1 -F1, 0.25" fins, longitudinal
MI - RAM - M1 -F2, 0.50" fins, longitudinal
MI - RAM - M1 -F3, 0.25" fins, transverse
MI - RAM - M1 -F4, 0.50" fins, transverse
essentially constant voltage which appears between the –IN and –OUT terminals. In overload the DC
voltage drop will rise as current increases. A few tens of millivolts appears between the +IN and
+OUT terminals. Care should be taken not to connect IN and OUT terminals (i.e. through scope probe
returns, grounds, etc.), as attenuation will be adversely affected.
Part Numbering
MI
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
-
RAM
Ripple Attenuator Module
-
M
-
Product Grade Temperatures (°C)
Grade Operating
Storage
I = - 40 to + 100 - 55 to + 125
M = - 55 to + 100 - 65 to + 125
MI-RAM Ripple Attenuator Modules
Set your site on VICOR at vicorpower.com
Rev. 1.1
2
Current Rating
1 = Up to 10 A
2 = Up to 20 A
Page 1 of 5
SPECIFICATIONS
PRODUCT GRADE SPECIFICATIONS
Parameter
I-Grade
M-Grade
Storage temperature
-55°C to +125°C
-65°C to +125°C
Operating temperature (baseplate)
-40°C to +100°C
-55°C to +100°C
12 hours, 29 cycles
96 hours, 213 cycles
12 cycles
-65°C to +100°C
12 cycles
-65°C to +100°C
-40°C, +80°C
-55°C, +80°C
2 years
2 years
MIL-STD-810
MIL-STD-810
NAVMAT P-4855-1A
NAVMAT P-4855-1A
Power cycling burn-in
Temperature cycled with power off
17°C per minute rate of change
Test data supplied at these temperatures [a]
Warranty
Environmental compliance
Derating
[a] Test data available for review or download from vicorpower.com
ENVIRONMENTAL QUALIFICATIONS
Parameter
Qualification
MIL-STD-810D, Method 500.2, Procedure III, explosive decompression (40 K ft.).
Altitude
MIL-STD-810D, Method 500.2, Procedure II, 40,000 ft., 1000 – 1500 ft./ min. to 70,000 ft., unit functioning
Explosive Atmosphere
MIL-STD-810C, Method 511.1, Procedure I
MIL-STD-810D, Method 514.3, Procedure I, category 6, helicopter, 20 g
Vibration
MIL-STD-810D, Method 514.3 random: 10 – 300 Hz @ 0.02 g 2 /Hz, 2000 Hz @ 0.002 g 2 / Hz, 3.9 total G rms
3 hrs / axis. Sine: 30 Hz @ 20 g, 60 Hz @ 10 g, 90 Hz @ 6.6 g, 120 Hz @ 5.0 g, 16.0 total G rms, 3 axes
MIL-STD-810E, Method 514.4, Table 514.4-VII, ±6 db/ octave, 7.7 G rms, 1hr/ axis
MIL-STD-810D, Method 516.3, Procedure I, functional shock, 40 g
MIL-STD-202F, Method 213B, 18 pulses, 60 g, 9 msec
Shock
MIL-STD-202F, Method 213B, 75 g, 11 ms saw tooth shock
MIL-STD-202F, Method 207A, 3 impacts / axis, 1, 3, 5 feet
Acceleration
MIL-STD-810D, Method 513.3, Procedure II Operational test, 9 g for 1 minute along 3 mutually perpendicular axes
Humidity
MIL-STD-810D, Method 507.2, Procedure I, cycle I, 240 hrs, 88% relative humidity
Solder Test
MIL-STD-202, Method 208, 8 hr. aging
Fungus
MIL-STD-810C, Method 508.1
Salt-Fog
MIL-STD-810C, Method 509.1
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MI-RAM Ripple Attenuator Modules
Set your site on VICOR at vicorpower.com
Rev. 1.1
Page 2 of 5
25 db
30 db
Attenuation
35 db
Output from the RAM 20 mV/cm
40 db
45 db
50 db
55 db
60 db
10 Hz
100 Hz
1 KHz
10 KHz
100 KHz
1 MHz
10 MHz
Frequency
Input to the converter 10 V/cm
Figure 1 —
Figure 2 — Attenuation vs. frequency (typical)
.01µF
.01µF
+
L1
+ In
Gate In
C1
+ S In
+S
VI-200
MI-200
Gate Out
–
+ In
+ Out
– In
MI-RAM
VI-RAM N/C
Trim
–S
– Out
+ Out
+ S Out
+
220µF
– S In
– In
0.22µF
Load
– S Out
– Out
.01µF
.01µF
Figure 3 — Connection diagram
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MI-RAM Ripple Attenuator Modules
Set your site on VICOR at vicorpower.com
Rev. 1.1
Page 3 of 5
MECHANICAL DRAWING
2.28
(57,9)
in
(mm)
0.49
(12,4)
0.30±0.015
(7,6)±(0,38)
Standard
0.080 Dia (2) places
Solder plate
over copper alloy
1.30
(33,0)
0.65
(16,5)
RoHS
0.080 Dia (2) places
Matte tin over copper
alloy
Pin #
4
9
3
8
2.10
(53,4)
MI-RAM
VI-RAM
7
2
6
1
5
FULL R
.15
(3,8)
.15
(3,8)
1.90
(48,3)
.70
.40 (17,8)
(10,2)
1.40
1.00 (35,6)
(25,4)
.35± .015
(8,9)±(0,38)
Function
1
+In
2
+Sense In
3
–Sense In
4
–In
5
+Out
6
+Sense
7
NC
8
–Sense
9
–Out
Standard
RoHS
0.040 (1,0) Dia (7) places
Solder plate
over copper alloy
0.040 (1,0) Dia (7) places
Matte tin over copper
alloy
Product ID
this surface
2.40
(61,0)
.30
(7,6) Min.
0.22
(5,6) Min.
.50
(12,7)
1.75 Max.
(44,4)
+.030 (0,76)
-.000 (0,00)
.01
.12
(3,0)
Aluminum Base
Figure 4 — Mechanical drawing
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MI-RAM Ripple Attenuator Modules
Set your site on VICOR at vicorpower.com
Rev. 1.1
Page 4 of 5
Warranty
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal
use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or
maintenance. Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original
purchaser only.
EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
Vicor will repair or replace defective products in accordance with its own best judgement. For service under this warranty, the
buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products
returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the
product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty.
Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is
assumed for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve
reliability, function, or design. Vicor does not assume any liability arising out of the application or use of any product or
circuit; neither does it convey any license under its patent rights nor the rights of others. Vicor general policy does not
recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten life or
injury. Per Vicor Terms and Conditions of Sale, the user of Vicor components in life support applications assumes all risks of
such use and indemnifies Vicor against all damages.
Vicor’s comprehensive line of power solutions includes high density AC-DC
and DC-DC modules and accessory components, fully configurable AC-DC
and DC-DC power supplies, and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its
use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunction
could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available upon request.
Specifications are subject to change without notice.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent
applications) relating to the products described in this data sheet. Interested parties should contact Vicor's Intellectual
Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: [email protected]
Technical Support: [email protected]
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MI-RAM Ripple Attenuator Modules
Set your site on VICOR at vicorpower.com
Rev. 1.1
11/08