FIAM110

FIAM™
110 V Input
Actual size:
2.28 x 2.2 x 0.5 in
57,9 x 55,9 x 12,7 mm
Filter Input Attenuator Module
Absolute Maximum Rating
Features
• RoHS Compliant (with F or G pin style)
• EMI filtering-EN50121-3-2*
• Transient protection-EN50155,
•
•
•
•
•
Parameter
+In to –In
EN50121-3-2
Low profile mounting options
500 W output power
60950-1 compliance
Mini-size package
Inrush current limiting
+Out to –Out
Mounting torque
Unit
Notes
154
Vdc
Continuous
385
V
20 ms
154
Vdc
Continuous
5(0.57)
in-lbs
6 each, #4-40 or M3
Operating temperature
– 55 to +100
°C
M -Grade
Storage temperature
– 65 to +125
°C
M -Grade
500 (260)
°F(°C)
<5 sec; wave solder
750 (390)
°F(°C)
<7 sec; hand solder
Pin soldering temperature
Product Highlights
The FIAM110 is a DC front-end module
designed for rail applications providing
transient protection, inrush current limiting and
EMI filtering (EN50121-3-2) in a Mini-size
package. The FIAM enables designers using
Vicor 110 Vin Mini, Micro, or Maxi or
VI/VE-200 and VI/VE-J00 (T input) DC-DC
converters to meet the transient immunity and
EMI requirements required for the rail industry
and protect system hardware from inrush
current. The FIAM110 accepts an input voltage
of 66 – 154 Vdc and provide up to 500 W of
output power and remote on/off control.
Rating
Thermal Resistance
Parameter
Min
Baseplate to sink
flat, greased surface
thermal pad (P/N 20264)
Typ
Max
Unit
0.16
°C/Watt
0.14
°C/Watt
8.0
°C/Watt
1.9
°C/Watt
Baseplate to ambient
Free Convection
1000 LFM
The FIAM110 is housed in an industry
standard "half brick" module measuring 2.28"
x 2.2" x 0.5" and depending upon model
selected, may be mounted on-board or in-board
for height critical applications.
Compatible Products
Part Numbering
• Mini, Micro, Maxi 110 V Input
DC-DC converters
FIAM 110
• VI / VE-200, VI / VE-J00 (“T” input)
Product
*
EMI performance is subject to a wide variety
of external influences such as PCB
construction, circuit layout etc. As such,
external components in addition to those listed
herein may be required in specific instances to
gain full compliance to the standards
specified.
110 Vin
Nominal
C
Product Grade Temperatures (°C)
Grade
Operating
Storage
E = – 10 to +100 – 20 to 125
C = – 20 to +100 – 40 to 125
T = – 40 to +100 – 40 to 125
H = – 40 to +100 – 55 to 125
M = – 55 to +100 – 65 to 125
[1]
Not intended for socket or Surfmate mounting
FIAM™
Rev 1.5
vicorpower.com
Page 1 of 6
12/2014
800 927.9474
1
1
2
S
N
F
G
K
=
=
=
=
=
=
=
Pin Style
Short
Long
Short ModuMate
Long ModuMate
Short RoHS
Long RoHS
[1]
Extra Long RoHS
1
Baseplate
1 = Slotted
2 = Threaded
3 = Thru-hole
110 V Input
Specifications
(typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified)
INPUT SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Input voltage
66
110
154
Vdc
Continuous
Inrush limiting
0.06
A/µF
Transient immunity
176
165
385
Vdc
Vdc
Vdc
Consistent with 100 ms per NF F 01-510
Consistent with 1 s per RIA 12
Consistent with 20 ms per RIA 12
Max
Unit
Notes
500
W
Output power derates linearly below 77 Vin to 400 W @ 66 Vin
2.5
%
V
500 W at 25°C baseplate
100
µF
Max
Unit
OUTPUT SPECIFICATIONS
Parameter
Min
Typ
Output power
Efficiency
Internal Voltage Drop
98
External capacitance
CONTROL PIN SPECIFICATIONS
Parameter
Min
Typ
ON / OFF control
Enable (ON)
0.0
1.0
Disable (OFF)
3.5
5.0
Notes
Referenced to –Vout
Vdc
100kΩ internal pull-up resistor
EMI
Standard
Notes
EN50121-3-2
150 kHz to 500 kHz - 99 dBµV quasi-peak
500 kHz to 30 MHz - 93 dBµV quasi-peak
EMI performance is subject to a wide variety of external influences such as PCB construction, circuit layout etc. As such, external components
in addition to those listed herein may be required in specific instances to gain full compliance to the standards specified.
IMMUNITY
Parameter
Typ. Value
Units
Notes
EN50121-3-2 (Table 7.3 Surges)
±2,000
±1,000
Vdc
Vdc
Waveform – 1.2 / 50 µs, 42 Ω, 0.5 µF, line to ground
Waveform – 1.2 / 50 µs, 42 Ω, 0.5 µF, line to line
Performance Criteria B - no damage to the product but a temporary change in
the intended DC voltage is acceptable as long as it self-recovers without user
intervention.
EN50121-3-2 (Table 7.2 Fast Transients)
±2,000
Vdc
5/50 ns, 5 kHz
Performance Criteria A - no damage to the product and no change to the
intended DC voltage level for a duration greater than 1.0 µsec.
EN50121-3-2 (Table 7.1 RF Common Mode)
0.15 to 80 MHz, 10 Vrms, 80% AM, 1 kHz
Performance Criteria A - no damage to the product and no change to the
intended DC voltage level greater than +/- 5%.
SAFETY SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
1,000
VRMS
1,414
Vdc
Notes
Dielectric withstand (I/O to baseplate)
FIAM™
Rev 1.5
vicorpower.com
Page 2 of 6
12/2014
800 927.9474
110 V Input
Specifications (Cont.)
AGENCY APPROVALS
Safety Standards
Markings
UL60950-1, CSA60950-1, EN60950-1, IEC 60950-1
EN60950-1
Notes
cTUVus
CE
Pending
Low Voltage Directive
GENERAL SPECIFICATIONS
Parameter
Min
Weight
Typ
Max
Unit
3.1
(88)
4
(113)
ounces
(grams)
2
years
Warranty
Remarks
MODULE ENVIRONMENTAL QUALIFICATION
Altitude
MIL-STD-810F, Method 500.4, Procedure I & II, 40,000 ft. and 70,000 ft. Operational.
Explosive Atmosphere
MIL-STD-810F, Method 511.4, Procedure I, Operational.
Vibration
EN 61373, Random Vibration: Category <0.3Kg, Freq range: 5-150Hz @ 5grms, 5hrs per axis.
MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J Main Rotor
with overall level of 5.6 G rms for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity Curve per Figure 514.5C-17
with overall level of 7.7 G rms for 1 hour per axis.
Shock
EN 61373, Shock: Long. / Trans. / Vert. Axis, peak acceleration: 5g / 2g / 1g, Duration: 50 ms/ 20 ms.
MIL-STD-810F, Method 516.5, Procedure I, Functional Shock, 40 g. MIL-S-901D, Lightweight Hammer Shock, 3 impacts/axis, 1,3,5 ft.
MIL-STD-202F, Method 213B, 60 g, 9 ms half sine. MIL-STD-202F, Method 213B, 75 g, 11 ms Saw Tooth Shock.
Acceleration
MIL-STD-810F, Method 513.5, Procedure II, table 513.5-II, Operational, 2-7 g, 6 directions.
Humidity
MIL-STD-810F, Method 507.4.
Solder Test
MIL-STD-202G, Method 208H, 8 hour aging.
MODULE ENVIRONMENTAL STRESS SCREENING
Parameter
H-Grade
M-Grade
Operating temperature
-40°C to +100°C
-55°C to +100°C
Storage temperature
-55°C to +125°C
-65°C to +125°C
Temperature cycling*
12 cycles
-65°C to +100°C
12 cycles
-65°C to +100°C
Ambient test @ 25°C
Yes
Yes
Power cycling burn-in
12 hours, 29 cycles
24 hours, 58 cycles
Functional and parametric ATE tests
-40°C and +100°C
-55°C and +100°C
Hi-Pot test
Yes
Yes
Visual inspection
Yes
Yes
vicorpower.com
vicorpower.com
Test data
*Temperature cycled with power off, 17°C per minute rate of change.
FIAM™
Rev 1.5
vicorpower.com
Page 3 of 6
12/2014
800 927.9474
110 V Input
Conducted Noise
Figure 1 — Conducted Noise (EN50121-3-2); FIAM110M21
and model V110A24C400BG DC-DC converter
operating at 110 Vdc, 375 W.
Figure 2 — Conducted Noise (EN50121-3-2); FIAM110M21
and model VE-2T3-EW + (3) VI-BT3-IW DC-DC
converters operating at 110 Vdc, 375 W.
Insertion Loss
Transient Immunity
Figure 3 — Insertion loss curve.
Figure 4 — Transient Immunity: FIAM output response to an
input transient.
Inrush Limiting
Figure 5 — Inrush current. (100 μ F external capacitance)
FIAM™
Rev 1.5
vicorpower.com
Page 4 of 6
12/2014
800 927.9474
110 V Input
Transient and Surge Protection
Note: The FIAM is shown in the on state. To disable,
open the connection between ON/OFF and –Out.
0.01 µF
4,700 pF
F1
FIAM110
+IN
NC
+OUT
+IN
GATE IN
GATE OUT
Input
0.2 µF
ON
OFF
PR
–OUT
–IN
EMI
GND
–IN
PC
C1
Mini, Maxi, Micro
110 Vdc Input
DC-DC Converter or
VI / VE-200 or VI / VE-J00
T input DC-DC Converter
+OUT
+S
SC
–S
–OUT
0.01 µF
4,700 pF
C1=100µF
F1=12 A Bussmann ABC — 12 or equivalent UL listed fuse.
Figure 6 — Typical connection diagram
Mechanical Diagram
Converter Pins
No.
Function
Label
1
+In
+
2
No
Connection
NC
3
Ground
EMI/GND
4
– In
–
5
– Out
–
6
ON/OFF
ON/OFF
7
*
Gout/NC
8
*
Gin/NC
9
+Out
+
* VI/VE-200/J00 modules only
connect to respective pins.
Otherwise, do not connect.
DIMENSION L
PIN SHORT – .54 [13.7]
PIN LONG–– .62 [15.7]
PIN EXTRA LONG–––- .71 [18.0]
NOTES:
1. MATERIAL:
BASE:
6000 SERIES ALUMINUM
COVER: LCP, ALUMINUM 3003 H14
PINS:
RoHS PINS GOLD PLATE 30 MICRO INCH MIN; NON-RoHS
PINS:
TIN/LEAD 90/10 BRIGHT
2. DIMENSIONS AND VALUES IN BRACKETS ARE METRIC
3. MANUFACTURING CONTROL IS IN PLACE TO ENSURE THAT THE SPACING
BETWEEN THE MODULES LABEL SURFACE TO THE PRINTED CIRCUIT BOARD
OF THE APPLICATION RANGES FROM DIRECT CONTACT (ZERO), TO THE
MAXIMUM GAP AS CALCULATED FROM THE TOLERANCE STACK-UP
AND IS NOT SUBJECT NEGATIVE TOLERANCE ACCUMULATION
PCB Mounting Specifications
ALL MARKINGS
THIS SURFACE
PCB THICKNESS
0.062 ±0.010
1,57 ±0,25
PLATED
THROUGH HOLE
DIA
1.790**
45,47
0.06
R
(4X)
1,5
ONBOARD
SOLDER
MOUNT
SHORT PIN STYLE
LONG PIN STYLE
(7X)
0.094 ±0.003
2,39 ±0,08
0.094 ±0.003
2,39 ±0,08
(2X)
0.164 ±0.003
4,16 ±0,08
0.164 ±0.003
4,16 ±0,08
ALUMINUM
BASEPLATE
0.158
4,01
1
2
3
PINS STYLES
SOLDER:TIN / LEAD PLATED
MODUMATE: GOLD PLATED COPPER
RoHS: GOLD PLATED COPPER
4
1.575**
40,00
1.900*
48.26
48,26
9
8
7
6
5
0.400*
10,16
0.43
0.45
0.45
11,5
0.700*
17,78
0.195
4,95
INBOARD
SOLDER
MOUNT
1.000*
25,40
1.400*
35,56
* DENOTES TOL =
0.53
13,5
±0.003
±0,08
** PCB WINDOW
FIAM™
Rev 1.5
vicorpower.com
Page 5 of 6
12/2014
800 927.9474
Consult Vicor Application Note:
Soldering methods and procedures for
1st and 2nd Generation modules.
110 V Input
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no
representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make
changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and
is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls
are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of
all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Vicor’s Standard Terms and Conditions
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request.
Product Warranty
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the
“Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment
and is not transferable.
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR
DISCLAIMS ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW)
WITH RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY,
FITNESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER
MATTER.
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable
for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes
no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and
components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and
operating safeguards.
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact
Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be
returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the
product was defective within the terms of this warranty.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS
PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support
devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform
when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the
user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products
and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the
products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is
granted by this document. Interested parties should contact Vicor's Intellectual Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: [email protected]
Technical Support: [email protected]
FIAM™
Rev 1.5
vicorpower.com
Page 6 of 6
12/2014
800 927.9474