DR120 series

DR120
1 2 0 W S i n g l e O u t put Industrial DIN Rail Power Supply
series
Universal AC input
Protections: Short circuit / Overload / Over voltage/ Over
temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
Isolation class II
LED indicator for power on
UL508 (industrial control equipment) approved
Fixed switching frequency at 55KHz
Model Number Output Volts Output Amps Min Load Efficiency Ripple and Noise DC Volt Adjust OVP
OTP SINGLE OUTPUT
DR120-12
12 Volts(DC)
DR120-24
24 Volts(DC)
DR120-48
48 Volts(DC)
85°C ±5°C
90°C ±5°C
90°C±-5°C
10 Amps
5 Amps
2.5 Amps
WWW.ASTRODYNE.COM
0 ~ 10Amps 80%
0 ~ 5Amps 84%
0 ~ 2.5Amps 85%
80mVpk-pk
80mVpk-pk
100mVpk-pk
12~14V
24~28V
48~53V
15~16.5V
298~33V
58~65V
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
DR120
1 2 0 W S i n g l e O u t put Industrial DIN Rail Power Supply
INPUT SPECIFICATIONS
Input Voltage Range
Frequency Range
Inrush Current, typ: (cold start)
Input Current
Leakage current
GENERAL SPECIFICATIONS
90~264VAC / 120-370 Volts (DC)
47-63 Hz
20 Amps @ 115VAC
40 Amps @ 230VAC
1.6 Amps. @ 115VAC
0.96 Amps. @ 230VAC
< 1mA / 240VAC
OUTPUT SPECIFICATIONS
Voltage and Current
Line Regulation
Load Regulation
Voltage Tolerance (Note 2)
Ripple/Noise (Note 1)
Hold Up Time @ FL
Setup, Rise Time @ FL
Over Current Protection
Over Voltage Protection
Over Temperature Protection
DC Voltage Adjust
series
See Selection Chart
± 0.5% max
± 1%
± 2% 12Volts(DC) only
± 1% 24~48Volts(DC)
See Selection Chart
36mS @ 230VAC
32ms@115VAC
500ms, 60ms/230VAC
70ms, 60ms/115VAC
105~160% rated output power
Constant current limit,auto recover
See Selection Chart
Shut down o/p voltage, re-power
See Selection Chart
Shut down o/p voltage, auto recover
See Selection Chart
Safety
Insulation Resistance
EMI
Harmonic Current
Isolation
EMS
UL508
TUV EN60950-1 approved
UL60950-1
≥ 100MΩ @ 500VDC
Compliance to EN55011
EN55022B (CISPR22B)
Compliance to EN61000-3-2,-3
3000VAC Input - Output
1500VAC Input - Ground
500VAC Output - Ground
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11,
ENV50204, EN55024, EN61000-6-2, EN61204-3,
heavy industry level,criteria A
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature Storage Temperature Relative Humidity
Temperature Coefficient
MTBF
Vibration
Mounting: -10°C to +60°C (See Derate Curve)
-20°C to +85°C, 10~95% RH
20 to +90% RH non cond
0.03% / °C (0-50°C)
136.8KHrs, MIL-HDBK-217F(25°C
10~500Hz, 2G10min./1cycle, period
for 60min. each along X, Y, Z axes
Compliance to IEC60068-2-6 PHYSICAL SPECIFICATIONS
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
Size
Millimeters
65.5 x 125.2 x 100
Inches
2.58” x 4.93 ” x 3.94 ”
Weight
27.87 oz (790g)
NOTE
1. Ripple & Noise are measured at 20MHz of bandwidth by using a 12”
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Tolerance: includes set up tolerance , line regulation and load regulation.
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
1 2 0 W S i n g l e O u t put Industrial DIN Rail Power Supply
WWW.ASTRODYNE.COM
DR120
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
1 2 0 W S i n g l e O u t put Industrial DIN Rail Power Supply
WWW.ASTRODYNE.COM
DR120
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458