RID-50 series

RID-50
50W D u a l Ou t p u t S w it c hi ng P ow er S upply
series
Isolated Output
Universal AC input
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
All using 105°C long life electrolytic capacitors
Model Number Output Volts Output Amps
DUAL OUTPUT
RID-50A
RID-50B
5 Volts(DC)
12 Volts(DC)
5 Volts(DC)
24 Volts(DC)
WWW.ASTRODYNE.COM
6 Amps
2 Amps
4 Amps
1.4 Amps
Ripple & Noise
Min Load
80mV pk-pk
120mV pk-pk
80mV pk-pk
150mV pk-pk
0.3 ~ 6Amps
0.2 ~ 3Amps
0.3 ~ 6Amps
0.2 ~ 2Amps
Line Reg
Volt Tolerance
±0.5%
±1.5%
±0.5%
±1.5%
±2.0%
±8.0%
±2.0%
+8,-4%
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
RID-50
50W D u a l Ou t p u t S w it c hi ng P ow er S upply
ENVIRONMENTAL SPECIFICATIONS
INPUT SPECIFICATIONS
Input Voltage Range
Frequency Range
Inrush Current, typ: (cold start)
Input Current
Leakage current
90 ~ 264 VAC; 125~373 Volts(DC)
47-63 Hz
33 Amps / 230VAC 1.3 Amps. @ 115VAC
0.8 Amps. @ 230VAC < 2mAmps /240VAC
OUTPUT SPECIFICATIONS
Voltage and Current
Line Regulation (Note 3)
Load Regulation (Note 4)
Voltage Tolerance (Note 2)
Ripple/Noise (Note 1)
Hold Up Time @ FL
Setup, Rise Time @ FL
Over Voltage Protection
Over Current Protection
DC Voltage Adjust
series
See Selection Chart
See Selection Chart
0.5%
See Selection Chart
See Selection Chart
60mS/230VAC
14mS/115VAC
500ms, 20m/230VAC
1200mS, 30mS/115VAC
5Volts only: 5.75 ~ 6.75VDC
Hiccup mode, auto recover
110 ~ 150% rated output power
Hiccup mode, auto recover
5Volts only: 4.75 ~ 5.5Volts(DC)
Oper. Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
MTBF
Vibration
-25°C to +70°C (See Derate Curve)
-40°C to +85°C, 10~95% RH
20 to +90% RH non cond
0.03% / °C (0-50°C) on +5V output
172.6 KHrs min,MIL-HDBK-217F (25°C)
10~500Hz, 5G10min./1cycle, period for 60min. each along X, Y, Z axes
PHYSICAL SPECIFICATIONS
Size
Millimeters
99 x 97 x 36 Inches
3.90” x 3.82 ” x 1.42 ”
Weight
14.46 oz (410g)
Note
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12”
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Tolerance : includes set up tolerance, line regulation and load regulation.
3. Line regulation is measured from low line to high line at rated load.
4. Load regulation is measured from 20% to 100% rated load, and other
output at 60% rated load.
GENERAL SPECIFICATIONS
Safety
Insulation Resistance
EMI
Harmonic Current
Efficiency
Isolation
EMS
UL60950-1
TUV EN60950-1 Approved ≥ 100MΩ @ 500VDC/25 °C/70%RH
Compliance to EN55022B(CISPR22B) Compliance to EN61000-3-2,-3
80%
3000VAC Input - Output
1500VAC Input - Ground
500VAC Output - Ground
Compliance to
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, (EN50082-2), heavy industry level, criteria A
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
WWW.ASTRODYNE.COM
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
50W D u a l Ou t p u t S w it c hi ng P ow er S upply
WWW.ASTRODYNE.COM
RID-50
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
50W D u a l Ou t p u t S w it c hi ng P ow er S upply
WWW.ASTRODYNE.COM
RID-50
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458