RS100 1 0 0 W S i n g l e O u t put Switching Power Supply series Universal AC input Protections:Short circuit/Over load/Over voltage Cooling by free air convection LED indicator for power on All using 105°C long life electrolytic capacitors High efficiency, long life and high reliability Model Number Output Volts SINGLE OUTPUT RS100-3.3 RS100-5 RS100-12 RS100-15 RS100-24 RS100-48 3.3 Volts(DC) 5 Volts(DC) 12 Volts(DC) 15 Volts(DC) 24 Volts(DC) 48 Volts(DC) WWW.ASTRODYNE.COM Output Amps 20 Amps 16 Amps 8.5 Amps 7.0 Amps 4.5 Amps 2.3 Amps Ripple & Noise 80mV pk-pk 80mV pk-pk 120mV pk-pk 120mV pk-pk 120mV pk-pk 200mV pk-pk Min Load 0~20Amps 0~16Amps 0~8.5Amps 0~7.0Amps 0~4.5Amps 0~2.3Amps DC Volt Adjust Load Reg Volt Tolerance 3.2~3.5Volt(DC) 4.75~5.5Volt(DC) 11.4~13.2Volt(DC 14.25~16.5Volt(DC) 22.8~26.4Volt(DC) 45.6~52.8Volt(DC) ±2.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±3.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 RS100 1 0 0 W S i n g l e O u t put Switching Power Supply INPUT SPECIFICATIONS Input Voltage Range Frequency Range Inrush Current, typ: (cold start) Input Current Leakage current Min Load 90 ~ 264 VAC; 125~373 Volts(DC) 47-63 Hz 40Amps / 230VAC 2.5 Amps. @ 115VAC 1.5 Amps. @ 230VAC < 2mAmps /240VAC See Selection Chart OUTPUT SPECIFICATIONS Voltage and Current Line Regulation (Note 3) Load Regulation (Note 4) Voltage Tolerance (Note2) Ripple/Noise (Note 1) Hold Up Time @ FL Setup, Rise Time @ FL Over Voltage Protection Over Current Protection DC Volt Adjust See Selection Chart ±0.5% See Selection Chart See Selection Chart See Selection Chart 100mS/230VAC 18mS/115VAC 500ms, 20m/230VAC 1200mS, 30mS/115VAC 3.8 ~ 4.45Volt(DC): 3.3Volts(DC) 5.75 ~ 6.75Volt(DC): 5Volts(DC) 13.8 ~ 16.2Volt(DC): 12Volts(DC) 17.25 ~ 20.25Volt(DC): 15Volts(DC) 27.6~ 32.4Volt(DC): 24Volts(DC) 55.2~ 64.8Volt(DC): 48Volts(DC) Hiccup mode, auto recov 110 ~ 150% rated output power Hiccup mode, auto recov See Selection Chart series Efficiency 74% (RS100-3.3) 77% (RS100-5) 81% (RS100-12) 82% (RS100-15) 84% (RS100-24) 84%(RS100-48) Isolation 3000VAC Input - Output 1500VAC Input - Ground 500VAC Output - Ground EMS Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204,EN61000-6-2(EN50082-2) heavy Industry Level, Criteria A ENVIRONMENTAL SPECIFICATIONS Oper. Temperature Storage Temperature Relative Humidity Temperature Coefficient MTBF Vibration -25°C to +70°C (See Derate Curve) -40°C to +85°C, 10~95% RH 20~90% RH non cond ±0.03% / °C (0-50°C) 260.8KHrs min,MIL-HDBK-217F(25°C) 10~500Hz, 5G10min./1cycle, period for 60min. each along X, Y, Z axes PHYSICAL SPECIFICATIONS Size Millimeters 159 x 97 x 38 Inches 6.26” x 3.81 ” x 1.50 ” Weight 21.16 oz (600g) GENERAL SPECIFICATIONS Note Safety Insulation Resistance EMI Harmonic Current 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 2. Tolerance : includes set up tolerance, line regulation and load regulation. 3. Line regulation is measured from low line to high line at rated load. 4. Load regulation is measured from 0% to 100% rated load. UL60950-1, TUV EN60950-1 Approved ≥ 100MΩ / 500Volts(DC) Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 All specifications are typical at nominal input, full load, and 25°C unless otherwise noted WWW.ASTRODYNE.COM Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 1 0 0 W S i n g l e O u t put Switching Power Supply WWW.ASTRODYNE.COM RS100 series ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 1 0 0 W S i n g l e O u t put Switching Power Supply WWW.ASTRODYNE.COM RS100 series ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458