RT50 5 0 W Tr i p l e O u t p ut Switching Power Supply series Universal AC input Protections:Short circuit/Over load/Over voltage Cooling by free air convection LED indicator for power on All using 105°C long life electrolytic capacitors High efficiency, long life and high reliability Model Number Output Volts TRIPLE OUTPUT RT50-A RT50-B RT50-C RT50-D 5 Volts(DC) 12 Volts(DC) -5 Volts(DC) 5 Volts(DC) 12 Volts(DC) -12 Volts(DC) 5 Volts(DC) 15 Volts(DC) -15 Volts(DC) 5 Volts(DC) 24 Volts(DC) 12 Volts(DC) WWW.ASTRODYNE.COM Output Amps Ripple & Noise 4 Amps 2 Amps 0.5 Amps 4 Amps 2 Amps 0.5 Amps 4 Amps 1.5 Amps 0.5 Amps 3 Amps 1 Amps 1 Amps 80mV pk-pk 120mV pk-pk 100mV pk-pk 80mV pk-pk 120mV pk-pk 120mV pk-pk 80mV pk-pk 120mV pk-pk 120mV pk-pk 80mV pk-pk 150mV pk-pk 120mV pk-pk Min Load 0.5~5Amps 0.2~2.5Amps 0.1~1Amps 0.5~5Amps 0.2~2.5Amps 0.1~1Amps 0~5Amps 0.2~2Amps 0.1~1Amps 0.5~5Amps 0.2~1.5Amps 0.1~1Amps Line Reg ±0.5% ±1.5% ±0.5% ±0.5% ±1.5% ±0.5% ±0.5% ±1.5% ±0.5% ±0.5% ±2.0% ±2.0% Load Reg Volt Tolerance ±1.0% ±3.0% ±1.0% ±1.0% ±3.0% ±1.0% ±1.0% ±3.0% ±1.0% ±1.0% ±3.0% ±4.0% ±2.0% ±6.0% ±2.0% ±2.0% ±6.0% ±2.0% ±2.0% +8,-4% ±2.0% ±2.0% +8,-4% ±6.0% ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 RT50 5 0 W Tr i p l e O u t p ut Switching Power Supply INPUT SPECIFICATIONS Input Voltage Range Frequency Range Inrush Current, typ: (cold start) Input Current Leakage current 90 ~ 264 VAC; 125~373 Volts(DC) 47-63 Hz 36Amps / 230VAC 1.3 Amps. @ 115VAC 0.8 Amps. @ 230VAC < 2mAmps /240VAC OUTPUT SPECIFICATIONS Voltage and Current Line Regulation (Note 4) Load Regulation (Note 5) Voltage Tolerance (Note 2) Ripple/Noise(Note 1) Hold Up Time @ FL Setup, Rise Time @ FL Over Voltage Protection Over Current Protection DC Volt Adjust See Selection Chart See Selection Chart See Selection Chart See Selection Chart See Selection Chart 60mS/230VAC 10mS/115VAC 500ms, 20m/230VAC 1200mS, 30mS/115VAC 5Volts only: : 5.75 ~ 6.75VDC Hiccup mode, auto recover 110 ~ 150% rated output power Hiccup mode, auto recover 5Volts only: 4.75 ~ 5.5V GENERAL SPECIFICATIONS Safety UL60950-1, TUV EN60950-1 Approved Insulation Resistance ≥ 100MΩ / 500Volts (DC) EMI Compliance to EN55022 (CISPR22) Class B Harmonic Current Compliance to EN61000-3-2,-3 Efficiency 77% (RT50-A/B) 78% (RT50-C) 80% (RT50-D) Isolation 3000VAC Input - Output 1500VAC Input - Ground 500VAC Output - Ground All specifications are typical at nominal input, full load, and 25°C unless otherwise noted WWW.ASTRODYNE.COM EMS series Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204,EN61000-6-2(EN50082-2) Heavy Industry Level, Criteria A ENVIRONMENTAL SPECIFICATIONS Oper. Temperature Storage Temperature Relative Humidity Temperature Coefficient MTBF Vibration -25°C to +70°C (See Derate Curve) -40°C to +85°C. 10~95% RH 20~95% RH non cond 0.03% / °C (0-50°C) on +5V output 169.2KHrs min, MIL-HDBK-217F(25 °C) 10~500Hz, 5G10min./1cycle, period for 60min. each along X, Y, Z axes PHYSICAL SPECIFICATIONS Size Millimeters 99 x 97 x 36 Inches 3.90” x 3.82 ” x 1.42 ” Weight 14.46 oz (410g) Note 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 2. Tolerance : includes set up tolerance, line regulation and load regulation. 3. Line regulation is measured from low line to high line at rated load. 4. Load regulation is measured from 0% to 100% rated load. Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 5 0 W Tr i p l e O u t p ut Switching Power Supply WWW.ASTRODYNE.COM RT50 series ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 5 0 W Tr i p l e O u t p ut Switching Power Supply WWW.ASTRODYNE.COM RT50 series ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458