USP225 2 2 5 W S i n g l e O u t put with PFC Function series Universal AC input Protections:Short circuit/Over load/Over voltage/Over temperature Free air convection for 150W and forced air convection for 225W Built in active PFC circuit compliance to EN61000-3-2 High power density 4.7w/cubic inch Active AC surge current limiting U-bracket low profil: 38mm Model Number Output Volts Output Amps Ripple & Noise Min Load 100mV pk-pk 100mV pk-pk 100mV pk-pk 100mV pk-pk 150mV pk-pk 250mV pk-pk 0~40Amps 0~40Amps 0~18.7Amps 0~15Amps 0~9.4Amps 0~4.7Amps DC Volt Adjust Efficiency SINGLE OUTPUT USP225-3.3 USP225-5 USP225-12 USP225-15 USP225-24 USP225-48 3.3 Volts(DC) 5 Volts(DC) 12 Volts(DC) 15 Volts(DC) 24 Volts(DC) 48 Volts(DC) WWW.ASTRODYNE.COM 40 Amps 40 Amps 18.7 Amps 15 Amps 9.4 Amps 4.7 Amps 2.97~3.6Volt(DC) 4.5~5.5Volt(DC) 10.8~13.2Volt(DC) 13.5~16.5Volt(DC) 21.6~26.4Volt(DC) 43.2~52.8Volt(DC) 72% 77% 83% 84% 85% 86% ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 USP225 2 2 5 W S i n g l e O u t put with PFC Function series INPUT SPECIFICATIONS GENERAL SPECIFICATIONS Input Voltage Range 90 ~ 264 VAC; 127~370 Volts(DC) Frequency Range 47-63 Hz Inrush Current, typ: (cold start)15Amps@115VAC / 30Amps@230VAC Input Current, typ. 3.3Volts(DC) 2.2Amps@115VAC / 1.1Amps@230VAC 5~48Volts(DC) 3.3Amps@115VAC/ / 1.6Amps@230VAC Leakage current < 3.5mAmps /240VAC Power Factor @ FL PF > 0.93/230VAC >0.97/115VAC Safety Insulation Resistance EMI Harmonic Current Isolation EMS OUTPUT SPECIFICATIONS Voltage and Current Line Regulation Load Regulation Voltage Tolerance (Note2) Ripple/Noise max(Note 1) Hold Up Time @ FL Setup, Rise Time @ FL Over Voltage Protection Over Current Protection Over Temperature Protection DC Volt Adjust See Selection Chart ±0.5% ±1.0% ±2.0% See Selection Chart 22mS/230VAC 22mS/115VAC 500ms, 30m/230VAC 1200mS, 30mS/115VAC 3.6 ~ 4.4Volt(DC): 3.3Volts(DC) 5.5 ~ 7.4Volt(DC): 5Volts(DC) 13.2 ~ 16.3Volt(DC): 12Volts(DC) 16.5 ~ 20.2Volt(DC): 15Volts(DC) 26.4~ 32.4Volt(DC): 24Volts(DC) 52.8~ 64.8Volt(DC): 48Volts(DC) Shutdown o/p, re-power 105~ 150% rated output power Constant current limiting, auto-recover 95°C ±5°C(RTH2: detect on heatsink of power transitor) Shutdown o/p voltge, re-power after cool down See Selection Chart All specifications are typical at nominal input, full load, and 25°C unless otherwise noted WWW.ASTRODYNE.COM UL60950-1, TUV EN60950-1 Approved ≥ 100MΩ / 500Volts(DC) Compliance to EN55022B (CISPR22B) Compliance to EN61000-3-2,-3 3000VAC Input - Output 1500VAC Input - Ground 500VAC Output - Ground Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light Industry Level, Criteria A ENVIRONMENTAL SPECIFICATIONS Oper. Temperature Storage Temperature Relative Humidity Temperature Coefficient MTBF Vibration -20°C to +65°C (See Derate Curve) -40°C to +85°C, 10~95% RH 20~90% RH non cond ±0.03% / °C (0-50°C) 220KHrs min,MIL-HDBK-217F(25°C) 10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes PHYSICAL SPECIFICATIONS Size Millimeters 202 x 101.5 x 38 Inches 7.68” x 2.17 ” x 0.91 ” Weight 12.35 oz (850g) Note 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 2. Tolerance : includes set up tolerance, line regulation and load regulation. Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 2 2 5 W S i n g l e O u t put with PFC Function WWW.ASTRODYNE.COM USP225 series ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 2 2 5 W S i n g l e O u t put with PFC Function WWW.ASTRODYNE.COM USP225 series ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458