USP225 series

USP225
2 2 5 W S i n g l e O u t put with PFC Function
series
Universal AC input
Protections:Short circuit/Over load/Over voltage/Over
temperature
Free air convection for 150W and forced air convection for
225W
Built in active PFC circuit compliance to EN61000-3-2
High power density 4.7w/cubic inch
Active AC surge current limiting
U-bracket low profil: 38mm
Model Number
Output Volts
Output Amps
Ripple & Noise
Min Load
100mV pk-pk
100mV pk-pk
100mV pk-pk
100mV pk-pk
150mV pk-pk
250mV pk-pk
0~40Amps
0~40Amps
0~18.7Amps
0~15Amps
0~9.4Amps
0~4.7Amps
DC Volt Adjust
Efficiency
SINGLE OUTPUT
USP225-3.3
USP225-5
USP225-12
USP225-15
USP225-24
USP225-48
3.3 Volts(DC)
5 Volts(DC)
12 Volts(DC)
15 Volts(DC)
24 Volts(DC)
48 Volts(DC)
WWW.ASTRODYNE.COM
40 Amps
40 Amps
18.7 Amps
15 Amps
9.4 Amps
4.7 Amps
2.97~3.6Volt(DC)
4.5~5.5Volt(DC)
10.8~13.2Volt(DC)
13.5~16.5Volt(DC)
21.6~26.4Volt(DC)
43.2~52.8Volt(DC)
72%
77%
83%
84%
85%
86%
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
USP225
2 2 5 W S i n g l e O u t put with PFC Function
series
INPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Input Voltage Range
90 ~ 264 VAC; 127~370 Volts(DC)
Frequency Range
47-63 Hz
Inrush Current, typ: (cold start)15Amps@115VAC / 30Amps@230VAC
Input Current, typ.
3.3Volts(DC)
2.2Amps@115VAC / 1.1Amps@230VAC
5~48Volts(DC)
3.3Amps@115VAC/ / 1.6Amps@230VAC
Leakage current
< 3.5mAmps /240VAC
Power Factor @ FL
PF > 0.93/230VAC
>0.97/115VAC
Safety
Insulation Resistance
EMI
Harmonic Current
Isolation
EMS
OUTPUT SPECIFICATIONS
Voltage and Current Line Regulation
Load Regulation
Voltage Tolerance (Note2)
Ripple/Noise max(Note 1)
Hold Up Time @ FL
Setup, Rise Time @ FL
Over Voltage Protection
Over Current Protection
Over Temperature Protection
DC Volt Adjust
See Selection Chart
±0.5%
±1.0%
±2.0%
See Selection Chart
22mS/230VAC
22mS/115VAC
500ms, 30m/230VAC
1200mS, 30mS/115VAC
3.6 ~ 4.4Volt(DC): 3.3Volts(DC)
5.5 ~ 7.4Volt(DC): 5Volts(DC)
13.2 ~ 16.3Volt(DC): 12Volts(DC)
16.5 ~ 20.2Volt(DC): 15Volts(DC)
26.4~ 32.4Volt(DC): 24Volts(DC)
52.8~ 64.8Volt(DC): 48Volts(DC)
Shutdown o/p, re-power
105~ 150% rated output power
Constant current limiting, auto-recover
95°C ±5°C(RTH2: detect on heatsink of power transitor) Shutdown o/p voltge, re-power
after cool down
See Selection Chart
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
WWW.ASTRODYNE.COM
UL60950-1, TUV EN60950-1 Approved
≥ 100MΩ / 500Volts(DC)
Compliance to EN55022B (CISPR22B)
Compliance to EN61000-3-2,-3
3000VAC Input - Output
1500VAC Input - Ground
500VAC Output - Ground
Compliance to
EN61000-4-2,3,4,5,6,8,11; ENV50204,
light Industry Level, Criteria A
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
MTBF
Vibration
-20°C to +65°C (See Derate Curve)
-40°C to +85°C, 10~95% RH
20~90% RH non cond
±0.03% / °C (0-50°C) 220KHrs min,MIL-HDBK-217F(25°C)
10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes
PHYSICAL SPECIFICATIONS
Size
Millimeters
202 x 101.5 x 38
Inches
7.68” x 2.17 ” x 0.91 ”
Weight
12.35 oz (850g)
Note
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12”
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Tolerance : includes set up tolerance, line regulation and load regulation.
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
2 2 5 W S i n g l e O u t put with PFC Function
WWW.ASTRODYNE.COM
USP225
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
2 2 5 W S i n g l e O u t put with PFC Function
WWW.ASTRODYNE.COM
USP225
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458