DR30 3 0 W S i n g l e O u t put Industrial DIN Rail Power Supply series Universal AC input Protections: Short circuit / Overload / Over voltage Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 Isolation class II LED indicator for power on Model Number Output Volts Output Amps Min Load Efficiency Ripple and Noise DC Volt Adjust OVP SINGLE OUTPUT DR30-5 DR30-12 DR30-15 DR30 -24 74% 81% 82% 83% 5.75~6.75V 13.8~16.2V 17.25~20.25V 27.6~32.4V 5 Volts(DC) 12 Volts(DC) 15 Volts(DC) 24 Volts(DC) WWW.ASTRODYNE.COM 3 Amps 2 Amps 2 Amps 1.5 Amps 0 ~ 3Amps 0 ~ 2Amps 0 ~ 2Amps 0 ~ 1.5Amps 80mVpk-pk 120mVpk-pk 120mVpk-pk 150mVpk-pk 4.75~5.5V 10.8~13.2V 13.5~16.5V 21.6~26.4V ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 DR30 3 0 W S i n g l e O u t put Industrial DIN Rail Power Supply INPUT SPECIFICATIONS Input Voltage Range Frequency Range Inrush Current, typ: (cold start) Input Current Leakage current DC Voltage Adjust GENERAL SPECIFICATIONS 90~264VAC / 120-370 Volts (DC) 47-63 Hz 15 Amps @ 115VAC 30 Amps @ 230VAC 0.88 Amps. @ 115VAC 0.48 Amps. @ 230VAC < 1mA / 240VAC See Selection Chart OUTPUT SPECIFICATIONS Voltage and Current Line Regulation Load Regulation Voltage Tolerance (Note 2) Ripple/Noise (Note 1) Hold Up Time @ FL Setup, Rise Time @ FL Over Current Protection Over Voltage Protection DC Voltage Adjust series See Selection Chart ±1% ±1% ±2% 5Volts(DC) only ±1% 12~24Volts(DC) See Selection Chart 100mS @ 230VAC 21mS @115VAC 500ms, 30ms/230VAC 500mS, 30mS/115VAC 105~160% rated output power Constant current limit,auto recover See Selection Chart Shut down o/p voltage, re-power See Selection Chart Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted WWW.ASTRODYNE.COM Safety UL60950-1 TUV EN60950-1 approved Design refer to EN50178 Insulation Resistance ≥ 100MΩ / 500Volts(DC) EMI Compliance to EN55022B (CISPR22B) Harmonic Current Compliance to EN61000-3-2,-3 Isolation 3000VAC Input - Output EMS Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3,heavy industry level,criteria A ENVIRONMENTAL SPECIFICATIONS Oper. Temperature Storage Temperature Relative Humidity Temperature Coefficient MTBF Vibration -20°C to +60°C (See derate curve) -40°C to +85°C, 10~95% RH 20 to +90% RH non cond 0.03% / °C (0-50°C) 441.5K Hrs min, MIL-HDBK-217F(25°C ) 10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes Mounting: Compliance to IEC60068-2-6 PHYSICAL SPECIFICATIONS Size Millimeters 78 x 93 x 56 Inches 3.07” x 3.66 ” x 2.20 ” Weight 9.52 oz (270g) NOTE 1. Ripple & Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 2. Tolerance: includes set up tolerance , line regulation and load regulation. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 3 0 W S i n g l e O u t put Industrial DIN Rail Power Supply WWW.ASTRODYNE.COM DR30 series ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 3 0 W S i n g l e O u t put Industrial DIN Rail Power Supply WWW.ASTRODYNE.COM DR30 series ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458