HRS TR636E

TR636E-10018
COMPREHENSIVE TEST REPORT
IT3 SERIES
APPROVED
TY.ARAI
CHECKED
TM.MATSUO
PREPARED
MN.NAGATA
HIROSE ELECTRIC CO.,LTD.
1
TR636E-10018
[1]
[2]
Objectives
To perform Telcordia GR1217 and EIA-TS1000 Qualification testing on IT3
board-to-board Connectors system
Test Samples
Socket : IT3M-300S-BGA(57) , IT3D-300S-BGA(57)
Interposer : IT3-300P-17H(03)
IT3D-300S-BGA(57)
IT3-300P-17H(03)
IT3M-300S-BGA(57)
[3]
Test period:
From: 2007- Dec -06
To:
[4]
2008- Feb- 06
Sample ID#
The test samples were coded in the following manner:
Group 1
Group 2
Group 3
Group 4
[5]
: 1-1 , 1-2 , 1-3 , 1-4 , 1-5
: 2-1 , 2-2 , 2-3 , 2-4 , 2-5
: 3-1 , 3-2 , 3-3 , 3-4 , 3-5
: 4-1 , 4-2 , 4-3 , 4-4 , 4-5
Measurement point
A
C
E
G
J
L
N
R
U
W
Signal (measurement point)
,
Ground
2
TR636E-10018
TEST PLAN FLOW DIAGRAM
SAMPLE PREPARATION
MATING/ UNMATING
FORCE
LLCR
LLCR
DURABILITY
LLCR
LLCR
DURABILITY
DURABILITY
Temperature -LIFE
LLCR
LLCR
LLCR
LLCR
THERMAL
Temperature -LIFE
Temperature -LIFE
LLCR
LLCR
LLCR
CYCLIC
VIBRATION
Mixed Flowing Gas
SHOCK
MATING/ UNMATING
FORCE
HUMIDITY
unmated (7 days)
LLCR
LLCR
LLCR
Mixed Flowing Gas
mated (7 days)
LLCR
THERMAL
DISTURBANCE
LLCR
RESEATING
LLCR
3
TR636E-10018
DATA SUMARY
TEST
REQUIREMENT
RESULT
GROUP 1
Mating Force
Unmating Force
135N Max.
116.7 N Max
15N Min.
91.9 N Min
LLCR
50.0 m ohm Max
Temperature Life
No Damage
LLCR
+20.0 m ohm Max. Chg.
+3.7 m ohm Max. Chg.
Mating Force
135N Max.
85.8 N Max
Unmating Force
29.6 m ohm Max
Passed
15N Min.
42.3 N Min
GROUP 2
LLCR
50.0 m ohm Max
25.5 m ohm Max
Durability
No Damage
Passed
LLCR
+20.0 m ohm Max. Chg.
+3.4 m ohm Max. Chg.
Thermal Shock
No Damage
Passed
LLCR
+20.0 m ohm Max. Chg.
+2.1 m ohm Max. Chg.
Cyclic Humidity
No Damage
Passed
LLCR
+20.0 m ohm Max. Chg.
+4.6 m ohm Max. Chg.
Reseating
LLCR
No Damage
Passed
+20.0 m ohm Max. Chg.
+9.0 m ohm Max. Chg.
LLCR
50.0 m ohm Max
34.8 m ohm Max
Durability
No Damage
Passed
LLCR
+20.0 m ohm Max. Chg.
+16.9 m ohm Max. Chg.
Temperature Life
No Damage
LLCR
+20.0 m ohm Max. Chg.
Random Vibration
No Damage
LLCR
+20.0 m ohm Max. Chg.
GROUP 3
Passed
+14.5 m ohm Max. Chg.
Passed
4
+18.2 m ohm Max. Chg.
TR636E-10018
DATA SUMARY - continued
TEST
REQUIREMENT
RESULT
LLCR
50.0 m ohm Max
28.0 m ohm Max
Durability
No Damage
Passed
LLCR
+20.0 m ohm Max. Chg.
+5.4 m ohm Max. Chg.
Temperature Life
No Damage
Passed
LLCR
+20.0 m ohm Max. Chg.
No Damage
+7.2 m ohm Max. Chg.
Passed
Mixed Flowing Gas (7 days)
+20.0 m ohm Max. Chg.
No Damage
+18.8 m ohm Max. Chg.
Passed
LLCR
+20.0 m ohm Max. Chg.
+18.6 m ohm Max. Chg.
Thermal Disturbance
No Damage
Passed
LLCR
+20.0 m ohm Max. Chg.
+18.1 m ohm Max. Chg.
GROUP 4
Mixed Flowing Gas (7 days)
LLCR
Reseating
LLCR
No Damage
+20.0 m ohm Max. Chg.
5
Passed
+18.6 m ohm Max. Chg.
TR636E-10018
Test Result
Group 1
6
TR636E-10018
MATING AND UNMATING FORCE
PURPOSE:
To determine the mechanical forces required to mate/unmate the connectors.
- - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - PROCEDURE:
1.
The test was performed in accordance with Paragraph 6.1.4 of Specification GR1217-Core and EIS 364, Test Procedure 13.
2.
The test samples were fixtured to the base plate of the test stand and applicable
force gauge.
3.
The fixturing was accomplished in a manner to prevent “bowing” of the test
samples during the performance of the test.
4.
The fixturing was accomplished to assure axial alignment and allow self
centering movement to exist.
5.
The test rate was 1.0 inch/minute maximum.
- - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - -- - - - - - - - - - - - - - -- - - - - - - - - - REQUIREMENT:
1.
The force required to mate the test samples shall not exceed 135 Newtons.
2.
The force required to unmate the test samples shall exceed 15 Newtons.
- - - - - - - - - - - - - -- - - - - -- - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - -- - - - - - - - RESULTS:
1.
The following is a summary of the data observed :
MATING FORCE
Sample ID#
( Newton )
UNMATING FORCE
( Newton )
1– 1
108.3
107.0
1– 2
91.0
91.9
1– 3
104.3
111.4
1– 4
107.3
110.1
1– 5
116.7
113.2
7
TR636E-10018
LOW LEVEL CIRCUIT RESITANCE (LLCR)
PURPOSE:
1.
To evaluate contact resistance characteristics of the contact systems under
conditions where applied voltages and currents do not alter the physical contact
interface and will detect oxides and films, which degrade electrical stability. It is
also sensitive to and may detect the presence of fretting corrosion induced by
mechanical or thermal environments as well as any significant loss of contact
pressure.
2.
This attribute was monitored after each preconditioning and/or test exposure in
order to determine said stability of the contact systems as they progress through
the applicable test sequences.
3.
The electrical stability of the system is determined by comparing the initial
resistance value to that observed after a given test exposure. The difference is
the change in resistance occurring whose magnitude established the stability of
the interface being evaluated.
- - - - - - - - - - - - - - -- - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - PROCEDURE:
1.
The test was performed in accordance with Paragraph 6.2.1 of Specification GR1217-CORE and EIA 364, Test Procedure 23 with the following conditions:
2.
3.
Test Conditions:
a)
Test Current
: 100 milliamps maximum
b)
Open Circuit Voltage
: 20 millivolts
c)
No. of Positions tested
: 100 per sample
The voltage probes were placed on the common buss of the daughter card test
board and the applicable PTH’s on the backplane.
4.
The points of application are shown in Figure #2.
--------------------------------------------------------------REQUIREMENT:
Low level circuit resistance shall not exceed 50.0 milliohms.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - -
8
TR636E-10018
RESULTS:
1.
The following is a summary of the data observed:
LOW LEVEL CIRCUIT RESISTANCE
(Milliohms)
Sample ID#
Avg.
Max.
Min.
1–1
19.8
28.6
17.5
1–2
19.4
22.7
17.1
1–3
20.7
29.6
18.4
1–4
19.8
23.8
17.8
1–5
20.0
27.8
17.8
9
TR636E-10018
10
TR636E-10018
TEMPERATURE LIFE
PUROSE:
To evaluate the impact on electrical stability of the contact system when exposed to a
thermal environment. Said environment may generate temperature dependent failure
mechanisms such as:
a)
Reduced normal (contact) force due to stress relaxation as a result of a
thermal environment.
b)
Dry oxidation of base metals and/or under plates, which have reached the
contacting surfaces by impurity, diffusion or pore corrosion.
c)
Dry oxidation and/or film formation of particulates which may have been
deposited on the contacting surfaces from the surrounding atmosphere.
---------------------------------------------------------------PROCEDURE:
1.
The test was performed in accordance with Paragraph 6.3.2 of Specification
GR-1217-CORE and EIA 364, Test Procedure 17, Test Condition 4.
2.
3.
Test Condition:
a)
Temperature
:
85°c
+ 2°C
b)
Duration
:
500 Hours
c)
Mated Condition
:
Mated
d)
Mounting Condition:
Mounted
Prior to performing variable measurements, the test samples were allowed to
recover to room ambient conditions.
4.
All subsequent variable testing was performed in accordance with the procedures
previously indicated.
---------------------------------------------------------------REQUIREMENTS:
1.
There shall be no evidence of physical damage or deterioration of the test
samples so exposed.
2.
The change in low level circuit resistance shall not exceed +20.0 milliohms.
3.
The mating and unmating forces shall not exceed 135 Newtons.
4.
The unmating forces shall exceed 15 Newtons.
----------------------------------------------------------------
11
TR636E-10018
RESULTS:
1.
There was no evidence of physical damage to the test samples as tested
2.
The following is a summary of the data observed:
CHANGE IN
LOW LEVEL CIRCUIT RESISTANCE
(Milliohms)
Avg.
Max.
Change
Change
1–1
+0.1
+3.4
1–2
-1.2
+1.8
1–3
-0.2
+2.8
1–4
+0.3
+3.3
1–5
+0.2
+3.7
Sample ID#
MATING FORCE
Sample ID#
UNMATING FORCE
( Newton )
( Newton )
1– 1
72.9
39.3
1– 2
85.8
36.5
1– 3
75.3
42.3
1– 4
83.5
41.6
1– 5
81.5
41.3
12
TR636E-10018
Test Result
Group 2
13
TR636E-10018
LOW LEVEL CIRCUIT RESISTANCE (LLCR)
PURPOSE:
1.
To evaluate contact resistance characteristics of the contact systems under
conditions where applied voltages and currents do not alter the physical contact
interface and will detect oxides and films, which degrade electrical stability. It is
also sensitive to and may detect the presence of fretting corrosion induced by
mechanical or thermal environments as well as any significant loss of contact
pressure.
2.
This attribute was monitored after each preconditioning and/or test exposure in
order to determine said stability of the contact systems as they progress through
the applicable test sequences.
3.
The electrical stability of the system is determined by comparing the initial
resistance value to that observed after a given test exposure. The difference is the
change in resistance occurring whose magnitude establishes the stability of the
interface being evaluated.
---------------------------------------------------------------PROCEDURE:
1.
The test was performed in accordance with EIA 364, Test Procedure 23 with the
following conditions:
2.
Test Conditions:
a) Test Current
:
100 milliamps maximum
b) Open Circuit Voltage
:
20 millivolts
c) No. of Positions tested :
3.
100 per test sample
The voltage probes were placed on the common buss of the daughter card test
board and the applicable PTH’s on the backplane.
4.
The points of application are shown in Figure #2.
- - - - - - - - - - -- - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - REQUIREMENT:
Low level circuit resistance shall not exceed 50.0 milliohms.
----------------------------------------------------------------
14
TR636E-10018
RESULTS:
1.
The following is a summary of the data observed:
LOW LEVEL CIRCUIT RESISTANCE
(Milliohms)
Sample ID#
Avg.
Max.
Min.
2–1
19.1
23.7
17.2
2–2
19.8
23.7
17.8
2–3
18.8
25.5
16.9
2–4
20.2
24.7
17.7
2–5
19.4
23.8
17.1
15
TR636E-10018
DURABILITY
PURPOSE:
1.
This is a preconditioning sequence, which is used to induce the type of wear on
the contacting surfaces, which may occur under normal service conditions. The
connectors are mated and unmated a predetermined number of cycles. Upon
completion, the units being evaluated are exposed to the environments as
specified to assess any impact on electrical stability resulting from wear or other
wear dependent phenomenon.
2.
This type of preconditioning sequence is also used to mechanically stress the
connector system as would normally occur in actual service. This sequence in
conjunction with other tests is used to determine if a significant loss of contact
pressure occurs from said stresses, which in turn, may result in an unstable
electrical condition to exist.
---------------------------------------------------------------PROCEDURE:
1.
The test was performed in accordance with EIA 364, Test Procedure 09.
2.
Test Conditions:
a)
3.
No. of Cycles
: 25
The test was performed manually in accordance with instructions provided by the
test sponsor.
4.
All subsequent variable testing was performed in accordance with the procedures
previously indicated.
- -------- ----------- -- -- -- ----- -- -- -- -- -- ------------------- -- -- ------- -- -- --
REQUIREMENTS:
1.
There shall be no evidence of physical damage to the test samples so tested.
2.
The change in low level circuit resistance shall not exceed +20.0 milliohms.
----------------------------------------------------------------
16
TR636E-10018
RESULTS:
1.
There was no evidence of physical damage to the test samples as tested.
2.
The following is a summary of the data observed :
CHANGE IN
LOW LEVEL CIRCUIT RESISTANCE
(Milliohms)
Avg.
Max.
Change
Change
2–1
+0.1
+2.5
2–2
-0.6
+1.2
2–3
-0.1
+3.4
2–4
-0.8
+2.1
2–5
-0.4
+1.2
Sample ID#
17
TR636E-10018
THERMAL SHOCK
PURPOSE:
To determine the resistance of a given electrical connector to exposure at extremes of
high and low temperatures and the shock of alternate exposure to these extremes,
simulating the worst probable conditions of storage, transportation and application.
-------------------------------------------------------------PROCEDURE:
1.
The test environment was performed in accordance with EIA 364, Test
Procedure 32, with the following conditions:
2.
Test Conditions:
a)
Number of Cycles
:
10 Cycles
b)
Hot Extreme
:
+85
+3°C/ -0°C
c)
Cold Extreme
:
-55
+0°C/ -3°C
d)
Time at Temperature
:
30 Minutes
e)
Mating Conditions
:
Mated
f) Mounting Conditions
:
Mounted
g)
:
Instantaneous
Transfer Time
3.
The total number of cycles was performed continuously.
4.
All subsequent variable testing was performed in accordance with the procedures
as previously indicated.
5.
Prior to performing variable measurements, the test samples were allowed to
recover to room ambient conditions.
---------------------------------------------------------------REQUIREMENTS:
1.
There shall be no evidence of physical damage to the test samples so tested.
2.
The change in low level circuit resistance shall not exceed +20.0 milliohms.
----------------------------------------------------------------
18
TR636E-10018
RESULTS:
1.
There was no evidence of physical damage to the test samples as tested.
2.
The following is a summary of the data observed:
CHANGE IN
LOW LEVEL CIRCUIT RESISTANCE
(Milliohms)
Sample ID#
Avg.
Max.
Change
Change
2–1
-0.1
+1.5
2–2
-0.6
+1.5
2–3
-0.3
+2.1
2–4
-0.6
+1.4
2–5
-0.1
+2.0
19
TR636E-10018
HUMIDITY (THERMAL CYCLING)
PURPOSE:
To evaluate the impact on electrical stability of the contact system when exposed to any
environment which may generate thermal/moisture type failure mechanisms such as:
a) Fretting corrosion due to wear resulting from micro motion, induced by
thermal cycling. Humidity accelerates the oxidation process.
b)
Oxidation of wear debris or from particulates from the surrounding
atmosphere, which may have become entrapped between the contacting
surfaces.
c) Failure mechanisms resulting from a wet oxidation process.
---------------------------------------------------------------PROCEDURE:
1.
The test environment was performed in accordance with EIA 364, TS1000.01
and Test Procedure 31 with the following conditions:
2.
Test Conditions:
3,
a)
Relative Humidity
: 80% @ 25°C, 50% @ 65°C
b)
Temperature Conditions
: 25°C to 65°C
c)
Number of Cycles
: 24
d)
Mating Conditions
: Mated
e)
Mounting Conditions
: Mounted
f)
Cycle Duration
: 3 Hours
Following the post cyclic humidity variable measurements, the samples were
subjected to a 3-cycle reseat test.
4.
Prior to performing variable measurements, the test samples were allowed to
recover to room ambient conditions.
5.
All subsequent variable testing was performed in accordance with the procedures
previously indicated.
---------------------------------------------------------------REQUIREMENTS:
1.
There shall be no evidence of physical deterioration of the test samples as
tested.
2.
The change in low level circuit resistance shall not exceed +20.0 milliohms.
----------------------------------------------------------------
20
TR636E-10018
RESULTS:
1.
There was no evidence of physical damage to the test samples as tested
2.
The following is a summary of the data observed:
CHANGE IN
LOW LEVEL CIRCUIT RESISTANCE
After Cyclic Humidity
After Reseating
Avg.
Max.
Avg.
Max.
Change
Change
Change
Change
2–1
+0.9
+4.6
+0.4
+2.9
2–2
-1.1
+2.3
-0.2
+3.4
2–3
-0.7
+1.2
-0.1
+2.5
2–4
-1.6
+1.3
+0.0
+9.0
2–5
-0.9
+0.9
-0.1
+2.8
Sample ID#
21
TR636E-10018
Test Result
Group 3
22
TR636E-10018
LOW LEVEL CURCUIT RESISTANCE (LLCR)
PURPOSE:
1.
To evaluate contact resistance characteristics of the contact systems under
conditions where applied voltages and currents do not alter the physical contact
interface and will detect oxides and films, which degrade electrical stability. It is
also sensitive to and may detect the presence of fretting corrosion induced by
mechanical or thermal environments as well as any significant loss of contact
pressure.
2.
This attribute was monitored after each preconditioning and/or test exposure in
order to determine said stability of the contact systems as they progress through
the applicable test sequences.
3.
The electrical stability of the system is determined by comparing the initial
resistance value to that observed after a given test exposure. The difference is
the change in resistance occurring whose magnitude establishes the stability of
the interface being evaluated.
- -------- ----------- -- -- -- ----- -- -- -- -- -- ------------------- -- -- ------- -- -- --
PROCEDURE:
1.
The test was performed in accordance with EIA 364, Test Procedure 23 with the
following conditions:
2.
3.
Test Conditions:
a)
Test Current
:
100 milliamps maximum
b)
Open Circuit Voltage
:
20 millivolts
c)
No. of Positions Tested
:
100 per test sample
The voltage probes were placed on the common buss of the daughter card test
board and the applicable PTH’s on the backplane.
4.
The points of application are shown in Figure #2.
---------------------------------------------------------------REQUIREMENT:
Low level circuit resistance shall not exceed 50.0 milliohms.
----------------------------------------------------------------
23
TR636E-10018
RESULTS:
1.
The following is a summary of the data observed:
LOW LEVEL CIRCUIT RESISTANCE
(Milliohms)
Sample ID#
Avg.
Max.
Min.
3–1
21.9
32.0
19.1
3–2
22.2
34.8
19.1
3–3
21.7
32.9
18.6
3–4
21.4
26.8
18.8
3–5
20.9
27.5
18.4
24
TR636E-10018
DURABILITY
PURPOSE:
1.
This is a preconditioning sequence, which is used to induce the type of wear on
the contacting surfaces, which may occur under normal service conditions. The
connectors are mated and unmated a predetermined number of cycles. Upon
completion, the units being evaluated are exposed to the environments as
specified to assess any impact on electrical stability resulting from wear or other
wear dependent phenomenon.
2.
This type of preconditioning sequence is also used to mechanically stress the
connector system as would normally occur in actual service. This sequence in
conjunction with other tests is used to determine if a significant loss of contact
pressure occurs from said stresses, which in turn, may result in an unstable
electrical condition to exist.
---------------------------------------------------------------PROCEDURE:
1.
The test was performed in accordance with EIA 364, Test Procedure 09.
2.
Test Conditions:
a)
3.
No. of Cycles
:
25
The test was performed manually in accordance with instructions provided by the
test sponsor.
4.
All subsequent variable testing was performed in accordance with the procedures
previously indicated.
----------------------------------------------------------------
REQUIREMENTS:
1.
There shall be no evidence of physical damage to the test samples so tested.
2.
The change in low level circuit resistance shall not exceed +20.0 milliohms.
----------------------------------------------------------------
25
TR636E-10018
RESULTS:
1.
There was no evidence of physical damage to the test samples as tested
2.
The following is a summary of the data observed:
CHANGE IN
LOW LEVEL CIRCUIT RESISTANCE
(Milliohms)
Avg.
Max.
Change
Change
3–1
+0.0
+16.9
3–2
-1.0
+14.1
3–3
-0.6
+8.2
3–4
+0.3
+7.4
3–5
+0.5
+4.7
Sample ID#
26
TR636E-10018
TEMPERATURE LIFE
PURPOSE:
To evaluate the impact on electrical stability of the contact system when exposed to a
thermal environment. Said environment may generate temperature dependent failure
mechanisms such as:
a) Dry oxidation of the contacting surfaces when non-noble finish systems are
utilized.
b)
Dry oxidation due to smearing of base metal and/or underplate on the
contact surfaces or exposure of same due to wear.
c)
Dry oxidation and/or film formation of particulates, which may have been
deposited on the contacting, surfaces from the surrounding atmosphere.
---------------------------------------------------------------PROCEDURE:
1.
The test samples were placed in the test chamber after it had reached
equilibrium at the specified temperature level. The test exposure was
performed in accordance with EIA 364, test Procedure 17, with the following
conditions:
2.
Test Condition:
a)
Temperature
:
115°C ± 2°C
b)
Duration
:
24 Hours
c)
Mated Condition
:
Mated
d)
Mounting Condition
:
Mounted
3.
Prior to performing variable measurements, the test samples were allowed to
recover to room ambient conditions.
4.
All subsequent variable testing was performed in accordance with the procedures
previously indicated.
----------------------------------------------------------------
27
TR636E-10018
REQUIREMENTS:
1.
There shall be no evidence of physical damage to the test samples as tested.
2.
The change in low level circuit resistance shall not exceed +20.0 milliohms.
---------------------------------------------------------------RESULTS:
1.
There was no evidence of physical damage to the test samples as tested
2.
The following is a summary of the data observed:
CHANGE IN
LOW LEVEL CIRCUIT RESISTANCE
(Milliohms)
Avg.
Max.
Change
Change
3–1
+0.2
+8.1
3–2
+0.6
+9.7
3–3
+1.3
+8.8
3–4
+1.7
+14.5
3–5
+0.7
+4.6
Sample ID#
28
TR636E-10018
VIBRATION, RANDOM
PURPOSE:
1.
To determine if the contact system is susceptible to fretting corrosion.
2.
To determine if the electrical stability of the system has degraded when exposed
to a vibratory environment.
3.
To determine if electrical discontinuities at the level specified exist.
---------------------------------------------------------------PROCEDURE:
1.
The test was performed in accordance with EIA 364, TS 1000.01 and EIA 364,
Test Procedure 28, Test Condition VII, Letter D.
2.
3.
Test Conditions:
a)
Power Spectral Density
:
0.02 g² / Hz
b)
G ‘RMS’
:
3.13
c) Frequency
:
20 to 500 Hz
d)
:
15 mins per axis (3 axis total)
Duration
Discontinuity monitoring was performed on the following 5 position sets per
sample : A1, L15, A30 , W30 , W1
4.
All subsequent variable testing was performed in accordance with procedures
previously indicated.
---------------------------------------------------------------REQUIREMENTS:
1.
There shall be no evidence pf physical damage to the test samples as tested.
2.
There shall be no contact interruption greater than 1.0 microsecond.
3.
The low level circuit resistance shall not exceed +20.0 milliohms.
----------------------------------------------------------------
29
TR636E-10018
RESULTS:
1.
There was no evidence of physical damage to the test samples as tested
2.
There was no interruption greater than 1.0 microsecond.
3.
The following is a summary of the data observed:
CHANGE IN
LOW LEVEL CIRCUIT RESISTANCE
(Milliohms)
Avg.
Max.
Change
Change
3–1
+2.2
+14.9
3–2
+0.5
+8.6
3–3
+1.6
+18.2
3–4
+1.7
+14.0
3–5
+2.9
+17.8
Sample ID#
30
TR636E-10018
Test Result
Group 4
31
TR636E-10018
LOW LEVEL CIRCUIT RESISTANCE (LLCR)
PURPOSE:
1.
To evaluate contact resistance characteristics of the contact systems under
conditions where applied voltages and currents do not alter the physical contact
interface and will detect oxides and films, which degrade electrical stability. It is
also sensitive to and may detect the presence of fretting corrosion induced by
mechanical or thermal environments as well as any significant loss of contact
pressure.
2.
This attribute was monitored after each preconditioning and/or test exposure in
order to determine said stability of the contact systems as they progress through
the applicable test sequences.
3.
The electrical stability of the system is determined by comparing the initial
resistance value to that observed after a given test exposure. The difference is
the change in resistance occurring whose magnitude establishes the stability of
the interface being evaluated.
--------------------------------------------------------------PROCEDURE:
1.
The test was performed in accordance with EIA 364, Test Procedure 23 with the
following conditions:
2.
3.
Test Conditions:
a)
Test Current
:
100 milliamps maximum
b)
Open Circuit Voltage
:
20 millivolts
c)
No. of Positions Tested
:
100 per test sample
The voltage probes were placed on the common buss of the daughter card test
board and the applicable PTH’s on the backplane.
4.
The points of application are shown in Figure #2.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - REQUIREMENT:
Low level circuit resistance shall not exceed 50.0 milliohms.
----------------------------------------------------------------
32
TR636E-10018
RESULTS:
1.
The following is a summary of the data observed:
LOW LEVEL CIRCUIT RESISTANCE
(Milliohms)
Sample ID#
Avg.
Max.
Min.
4–1
20.8
24.1
18.8
4–2
20.5
24.0
18.4
4–3
20.6
23.5
18.4
4–4
21.5
28.0
18.5
4–5
21.3
27.6
18.7
33
TR636E-10018
DURABILITY
PURPOSE:
1.
This is a preconditioning sequence, which is used to induce the type of wear on
the contacting surfaces, which may occur under normal service conditions. The
connectors are mated and unmated a predetermined number of cycles. Upon
completion, the units being evaluated are exposed to the environments as
specified to assess any impact on electrical stability resulting from wear or other
wear dependent phenomenon.
2.
This type of preconditioning sequence is also used to mechanically stress the
connector system as would normally occur in actual service. This sequence in
conjunction with other tests is used to determine if a significant loss of contact
pressure occurs from said stresses, which in turn, may result in an unstable
electrical condition to exist.
---------------------------------------------------------------PROCEDURE:
1.
The test was performed in accordance with EIA 364, Test Procedure 09.
2.
Test Conditions:
a)
3.
No. of Cycles
:
25
The test was performed manually in accordance with instructions provided by the
test sponsor.
4.
All subsequent variable testing was performed in accordance with the procedures
previously indicated.
----------------------------------------------------------------
34
TR636E-10018
REQUIREMENTS:
1.
There shall be no evidence of physical damage to the test samples so tested.
2.
The change in low level circuit resistance shall not exceed +20.0 milliohms.
---------------------------------------------------------------RESULTS:
1.
There was no evidence of physical damage to the test samples as tested
2.
The following is a summary of the data observed:
CHANGE IN
LOW LEVEL CIRCUIT RESISTANCE
(Milliohms)
Sample ID#
Avg.
Max.
Change
Change
4–1
-0.2
+1.6
4–2
-0.2
+3.3
4–3
+0.4
+3.2
4–4
-0.5
+4.3
4–5
-0.7
+5.4
35
TR636E-10018
TEMPERATURE LIFE
PURPOSE:
To evaluate the impact on electrical stability of the contact system when exposed to a
thermal environment. Said environment may generate temperature dependent failure
mechanisms such as:
a) Dry oxidation of the contacting surfaces when non-noble finish systems are
utilized.
b) Dry oxidation due to smearing of base metal and/or underplate on the contact
surfaces or exposure of same due to wear.
c) Dry oxidation and/or film formation of particulates which may have been
deposited on the contacting surfaces from the surrounding atmosphere.
---------------------------------------------------------------PROCEDURE:
1.
The test samples were placed in the test chamber after it had reached
equilibrium at the specified temperature level. The test exposure was
performed in accordance with EIA 364, Test Procedure 17, with the following
conditions:
2.
3.
Test Conditions:
a)
Temperature
:
115°C ± 2°C
b)
Duration
:
24 hours
c)
Mated Condition
:
Mated
d)
Mounted Condition
:
Mounted
Prior to performing variable measurements, the test samples were allowed to
recover to room ambient conditions.
4.
All subsequent variable testing was performed in accordance with the procedures
previously indicated.
----------------------------------------------------------------
36
TR636E-10018
REQUIREMENTS:
1.
There shall be no evidence of physical damage to the test samples as tested.
2.
The change in low level circuit resistance shall not exceed +20.0 Milliohms.
----------------------------------------------------------------
RESULTS:
1.
There was no evidence of physical damage to the test samples as tested
2.
The following is a summary of the data observed:
CHANGE IN
LOW LEVEL CIRCUIT RESISTANCE
(Milliohms)
Avg.
Max.
Change
Change
4–1
+0.2
+3.0
4–2
+0.4
+3.3
4–3
+0.7
+7.2
4–4
+0.0
+6.8
4–5
+0.2
+6.5
Sample ID#
37
TR636E-10018
MIXED FLOWING GAS
PURPOSE:
1.
To determine the impact on electrical stability of contact interfaces when the test
samples are exposed to a mixed flowing gas environment. Said environment is
based on field data simulating typical, severe, non-benign environments. Said
exposure is indicative of expected behavior in the field.
2.
Mixed flowing gas tests (MFG) are environmental test procedures whose primary
purpose is to evaluate product performance under simulated storage or operating
(field) conditions. For parts involving plated contact surfaces, such tests are
also used to measure the effect of plating degradation (due to the environment)
on the electrical and durability properties of contact or connector system. The
specific test conditions are usually chosen so as to stimulate, in the test
laboratory, the effects of certain representative field environments or
environmental severity levels on standard metallic surfaces.
---------------------------------------------------------------PROCEDURE:
1.
The test environment was performed in accordance with EIA 364, TS1000.01
and EIA 364, Test Procedure 65 with the following conditions.
2.
Environmental Conditions:
a)
Temperature
: 30°C ± 1°C
b)
Relative Humidity
: 70% ± 2%
c)
C12
: 10 ± 3 ppb
d)
NO2
: 200 ± 50 ppb
e)
H2S
: 10 ± 5 ppb
f)
SO2
: 100 ± 20 ppb
g)
Exposure Time
: 20 Days Total
h)
Mating Conditions
: Day 1-10
All samples exposed unmated
: Day 11-20
All samples exposed mated
i)
Mounting Conditions
: Mounted
3.
The test chamber was allowed to stabilize at the specified conditions indicated.
4.
After stabilization, the test samples and control coupons were placed in the
chamber such that they were no closer than 2.0” from each other and/or the
chamber walls.
38
TR636E-10018
PROCEDURE: - continued
5.
The test samples were handled in a manner so as not to disturb the contact
interface.
6.
After placement of the test samples in the chamber, it was allowed to re-stabilize
and adjust as required to maintain the specified concentrations and conditions.
7.
The test chamber was monitored periodically during the exposure period to
assure the environmental conditions as specified were maintained.
8.
During the exposure, resistance measurements were taken at specific intervals
and in the following sequence:
a)
Place the test samples in the test chamber.
b)
At each designated measurement period, remove the test units from the test
chamber. The test samples were exposed to room ambient for two hours
prior to making measurements.
c)
Measure and record low level circuit resistance measurements.
d)
Upon completion of the measurements, place the test units back into the test
chamber until the next measurement interval or until completion of the test
duration.
9.
10.
Testing was performed in the following sequence:
a)
MFG,
7 Days
(Unmated)
b)
LLCR
c)
MFG,
7 Days
(Mated)
d)
LLCR
e)
Thermal Disturbance
f)
LLCR
g)
Reseat,
h)
LLCR
3X
(10 cycles)
(Unmate/Mate)
Thermal Disturbance was performed in accordance with EIA 364, Test Procedure
32 and the following conditions:
11.
a)
Number of Cycles
:
10 Cycles
b)
Hot Extreme
:
+85 +3°C/-0°C
c)
Cold Extreme
:
+15
d)
Time at temperature
:
10 Minutes
e)
Ramp Time Hot to Cold
:
15 Minutes
f)
Ramp Time Cold to Hot
:
15 Minutes
+0°c/-3°C
All subsequent variable testing was performed in accordance with the procedures
previously indicated.
39
TR636E-10018
---------------------------------------------------------------REQUIREMENTS:
1.
There shall be no evidence of damage or corrosion to the test samples as
exposed which will cause mechanical or electrical malfunction of the said
samples.
2.
The change in low level circuit resistance shall not exceed +20.0 milliohms.
---------------------------------------------------------------RESULTS:
1.
There was no evidence of physical damage to the test samples as tested
2.
The following is a summary of the data observed :
CHANGE IN
LOW LEVEL CIRCUIT RESISTANCE
(Milliohms)
Unmated 7 days
Mated 7 days
Avg.
Max.
Avg.
Max.
Change
Change
Change
Change
4–1
+3.2
+18.7
+6.4
+17.4
4–2
+5.5
+17.7
+10.0
+18.4
4–3
+6.0
+18.8
+11.1
+18.6
4–4
+4.7
+16.4
+8.3
+16.9
4–5
+5.9
+17.3
+6.4
+17.2
Sample ID#
After Thermal Disturbance
After Reseating
Avg.
Max.
Avg.
Max.
Change
Change
Change
Change
4–1
+7.7
+18.5
+10.2
+18.3
4–2
+8.3
+18.1
+7.1
+17.3
4–3
+6.2
+17.2
+11.6
+18.6
4–4
+5.6
+15.4
+9.0
+17.8
4–5
+3.9
+16.3
+8.2
+18.0
Sample ID#
40