TACHO HiTESTER 3403, 3404 Field measuring instruments High 0.01 r/min resolution Wide range digital tachometer covers up to 100,000r/min 3404 3403 Digital tachometers offering high resolution and covering a wide range up through 100,000 r/min. Choose from two models to match your needs: the basic 3403 and the multi-functional 3404. Record r/min data with the Universal 3404 High-precision, high-resolution Maximum 0.01 r/min resolution and high ± 1 dgt. precision make the tachometer effective for precise measurements. Internal micro-computer for multi-functional performance (3404 only) Measurement range Note: Contact adapter may be used for rotations up to 20,000 r/min. NORMAL, MIN and MAX modes (MIN and MAX modes only on the 3404) SLOW sampling (3403 and 3404) r/min MIN, MAX-Holds minimum and maximum r/min, r/s values. TOTAL-Provides total rotation counts from 0 to 500,000 for real-time rotation count measurement. PERIOD-Accurately measure rotation pulses from 600 ms to 2.000 seconds. Accuracy Range Accuracy 30.00 to 199.99 30.00 to 99.99 ±1 dgt. 100.00 to 199.99 ±2 dgt. 200.0 to 999.9 ±1 dgt. 1000.0 to 1999.9 ±2 dgt. 2000 to 9999 ±1 dgt. 10000 to 19999 ±2 dgt. ±10 dgt. 0.5000 to 0.9999 ±1 dgt. 1.0000 to 1.9999 ±2 dgt. 2.000 to 9.999 ±1 dgt. 10.000 to 19.999 ±2 dgt. 20.00 to 99.99 ±1 dgt. 100.00 to 199.99 ±2 dgt. 200.0 to 999.9 ±1 dgt. 1000.0 to 1600.0 ±2 dgt. 120.00 to 199.90 200.0 to 1999.0 ±40 dgt. 200.0 to 999.0 ±20 dgt. 1000.0 to 1999.0 ±40 dgt. 2000 to 9990 ±20 dgt. 10000 to 19990 ±40 dgt. ±200 dgt. 2.000 to 9.990 ±20 dgt. 10.000 to 19.990 ±40 dgt. 20.00 to 99.90 ±20 dgt. 100.00 to 199.90 ±40 dgt. 200.0 to 999.0 ±20 dgt. 1000.0 to 1600.0 ±40 dgt. 200.0 to 1999.9 2000 to 19999 20000 to 99990 0.5000 to 1.9999 2.000 to 19.999 r/s FAST sampling (3404 only) Range 20.00 to 199.99 200.0 to 1600.0 Note: Display will read 0.0 below 30 r/min or 0.5 r/s. Analog output (3404 only) Stable analog signal output from low to high speeds provides clear recording by merely connecting your existing recorder. Output sampling mode can be set to slow or fast to meet different application needs. Double performance from one tachometer By using the optional 9213 contact adapter the 3403 and 3404 become contact-type tachometers, while the peripheral ring can be used in applications like measurement of conveyer line speed (period). Simple reflector detection check LED and buzzer signals confirm that the light pulses reflected from the tape on the rotating body are being picked up. Signals can be turned on and off freely. Specifications :Visible light reflection :LCD 4 1/2 digits (5 digits with the last digit fixed at 0 for 20,000 r/min and higher). TOTAL measurement 5 digits (3404 only). HOLD, r/min, r/s, B marks HOLD (MAX, MIN, TOTAL, PERIOD, msec, msec, sec [3404 only] ) :----- displays Over range display :50 to 200 mm (1.97" to 7.87") Detection distance Reflected light detection :Buzzer and LED confirmation Operating temperature/ :0 to 40 ˚C 80% RH or less (no condensation) humidity :1000m VDC f.s. (3404 only). Analog output Output accuracy ±1% rdg. ±1m V, output resistance 1kW :R6P (AA) × 4 (continuous use Power supply of 16 hours) or AC adapter (6V, 300mA, 100V only) :Approx. 182H × 62W × 38Dmm r/s 20.00 to 199.90 200.0 to 1600.0 Note: Display will read 0.0 below 120 r/min or 2 r/s. TOTAL mode (3404 only) - 0 to 499999 5-digit display. (dicimal point code used for 100,000 counts and over) PERIOD mode (3404 only) 600 ms to 2.000 s - ±1 dgt. for 4 digit display, ±2 dgt. for 4 1/2 - digit display. Single-function type Multi-function type 3403 3404 Non-contact Measurement method Non-contact 0.5 to 2.0 sec SLOW mode 0.5 to 2.0 sec Sampling rate FAST mode 0.1 to 0.5 sec _ FAST/SLOW mode select MAX.,MIN., TOTAL Mode (total count _ select measurement) PERIOD (period measurement) _ Analog output Auto-range function Data hold function Tripod mounting AC power jack Reflective tape Reflective tape 9211 Accessories 9211 (1 sheet) (1 sheet) Carrying case Output cord 9094 Carrying case (7.17"H × 2.44"W × 1.50"D) Approx. 260g (9.2 oz.) Switch units even during measurement. Reflective tape 9211 (10 sheets) Auto-ranging function covers from 30 to 100,000 r/min. 9213 Contact adapter (30 pieces per sheet, each sheet 12 × 12 mm) Tripod mounting socket included. AC and DC power supplies may be used. (includes 9032, two 9033 and 9212) 9032 9033 Metal contact tip Rubber contact tip Output cord 9094 (1.5 m) 9212 Peripheral ring 9213 dimensions: 70H × 62W × 39Dmm (Not including contact tip) HIOKI (Shanghai) Sales & Trading Co., Ltd. : 1608-1610 Shanghai Times Square Office, 93 Huai Hai Zhong Road, Shanghai, P.R.China POSTCODE: 200021 TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360 E-mail: [email protected] HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: [email protected] 20000 to 99900 2.000 to 19.990 Optional accessories r/min ↔ r/s HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: [email protected] 2000 to 19990 Selection guide Measurement method Display Dimensions and mass r/min DISTRIBUTED BY Beijing Office : A-2602 Freetown, 58 Dong San Huan Nan Road Beijing, P.R.China POSTCODE: 100022 TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090 E-mail: [email protected] Guangzhou Office : Room A-3206, Victory PlazaServices Center, No.103, Tiyuxi Road, Guangzhou, P.R.China POSTCODE:510620 TEL +86-20-38392673/2676 FAX +86-20-38392679 E-mail: [email protected] All information correct as of Dec. 2, 2009. All specifications are subject to change without notice. 3403E3-9ZB Printed in Japan