IMPEDANCE ANALYZER IM3570 Component measuring instruments Single Device Solution for High Speed Testing and Frequency Sweeping With this new IM3570 Impedance Analyzer, an LCR meter and an impedance analyzer capable of measurement frequencies of 4 Hz to 5 MHz and test signal levels of 5 mV to 5 V have been combined into one measuring instrument. Advanced capabilities include LCR measurement with AC signals, resistance measurement with direct current (DCR), and sweep measurement which continuously changes the measurement frequency and measurement level. The IM3570 facilitates high-speed continuous measurement under different measurement conditions and measurement modes, so inspection lines which up to now have required multiple measuring instruments can be equipped with just one device. 2 LCR measurement, DCR measurement, and Sweep measurement Continuous Measurement and High-speed Testing Achieved with One Instrument IMPEDANCE ANALYZER IM3570 Measurements recommended with IMPEDANCE ANALYZER IM3570 1. Testing the resonance characteristics of piezoelectric elements Reduce Equipment Costs with Just 1 Device! Frequency sweep measurement can be used to measure the resonance frequency and its impedance, and then the peak comparator function can be used to make a pass/fail judgment on the resonance state. In LCR mode, you can test capacitance by performing C measurement between 1 kHz and 120 Hz. Frequency sweep measurement Z peak comparator screen LCR mode Cs display screen (1 kHz measurement) High Speed and High Accuracy Frequency sweep measurement (impedance analyzer) and C measurement can be performed continuously with one instrument. Continuous measurement screen Advantage #1 -- Measurement time shortened The measurement time has been shortened from previous models, achieving maximum speeds of 1.5ms* (1 kHz) and 0.5ms* (100kHz) in LCR mode. This is a significant increase in speed compared with previous Hioki products (3522-50 and 3532-50 with basic speed of 5ms). Faster speed contributes to an increase in test quantities. Furthermore, sweep measurement, which requires multiple points to be measured, realizes the quick speed of 0.3ms per point. * When the display is off (time increases by 0.3 ms when the display is on). Measurement frequency IM3570 FAST measurement time 3532-50 FAST measurement time 1MHz 0.5ms 6ms 100kHz 0.5ms 6ms 10kHz 0.6ms 1kHz 1.5ms 100Hz Reference value 15ms 5ms 11ms 15ms Comparison of measurement time of IM3570 and 3532-50 3 Perfect Impedance Analyzer for Production Lines 2. C-D and low ESR measurement of functional polymer capacitors LCR mode Cs and D display screen (120 Hz measurement) LCR mode Rs display screen (100 kHz measurement) Continuous measurement screen Make continuous tests for different measurement items under different measurement conditions (frequency, level, and mode). C-D (120 Hz) and low ESR (100 kHz) measurement can be performed for functional polymer capacitors. Advantage #2 -- Low-impedance measurement accuracy improved Repeat accuracy of IM3570 when measuring 1 mΩ 100 times Reference value Measurement speed SLOW2 SLOW 0.03% 0.08%, 5.9ms 0.12%, 1.7ms MID FAST 44.5ms 0.5ms 0.54% Variation [%] and measurement time [ms] A one-digit improvement in repeat accuracy during low-impedance measurement has been achieved compared with previous Hioki products. For example, when the condition is 1 mΩ (1V, 100 kHz) and the measurement speed is MED, stable measurement with a repeat accuracy (variation)* of 0.12% is possible, making this instrument suitable for 100 kHz ESR measurement. * Repeat accuracy (variation) is calculated based on the difference between the maximum and minimum values. 3. DCR and L-Q measurement of inductors (coils and transformers) L/Q display screen (1 kHz, 1 mA constant current measurement) DCR display screen (DC measurement) L/Q/ DCR continuous measurement screen L/Q (1 kHz, 1 mA constant current measurement) and DCR (DC measurement) display screen The instrument can continuously measure L-Q (1 kHz, 1mA constant current) and DCR, and display the numerical values on the same screen. Cur rent dependent elements such as coils incorporating cores for which the inductance value varies depending on the applied current can be measured with a constant current (CC). Since there is a one-digit improvement in repeat accuracy during low impedance measurement compa red with previous products, st able measurement of DCR can be expected. Advantage #3 By improving the measurement accuracy of θ compared with previous Hioki products, measurement with an absolute accuracy and repeat accuracy of one-digit better than before can be performed for high Q and Rs values for which θ is in the vicinity of 90°. The measurement frequency of a coil differs dep end i ng on t he appl icat ion. T he wide measurement range of 4 Hz to 5 MHz facilitates the measurement of various coils. Constant current sweep measurement enables a current characteristic graph to be displayed for current dependent elements. Frequency sweep measurement Z-θ measurement screen CC value sweep measurement Ls measurement screen 4 Test Efficiency Improved by High-speed and High-accuracy Measurements Features of IM3570 ● Low-capacitance (high-impedance) measurement with improved stability There is a one-digit improvement in repeat accuracy during low-capacitance (high-impedance) measurement compared with previous Hioki products. For example, when the condition is 1 pF (1 MHz, 1 V) and the measurement speed is SLOW2, stable measurement with a repeat accuracy (variation)* of 0.01% is possible. At the same time, phase repeat accuracy is also improved, which in turn has improved the stability of D measurement during low-capacitance (highimpedance) measurement. * Repeat accuracy (variation) is calculated based on the difference between the maximum and minimum values. ● Wide setting range for measurement frequency IM3570 allows DC or a frequency band within the range of 4 Hz to 5 MHz to be set with five-digit resolution (testing at less than 1 KHz has a 0.01 Hz resolution). This enables the measurement of resonance frequency and measurement and evaluation in a state close to that of actual operating conditions. ● 15 parameters measured The following parameters can be measured and selected parameters can be captured by a computer: Z, Y, θ, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Ls, Lp, Cs, Cp, D (tanδ), and Q. ● Incorporates contact check function (open-circuit check) The contact check function for four-terminal measurement (only for low impedance high accuracy mode) and two-terminal measurement prevents measurement in a state in which a measurement electrode is not in contact with the measurement object. ● Comparator and BIN functions In LCR mode, the instrument allows for Hi, IN, and Lo judgments of two types from the measurement items on one screen. For the judgment method, % setting and ∆% setting are available in addition to absolute value setting. If continuous measurement is used, judgments which span over multiple measurement conditions and measurement items are possible. The BIN function can be used to classify two types of measurement items on one screen into 10 categories and out of range. In analyzer mode, the peak comparator for judging whether resonance points pass or fail can be used. Repeat accuracy of IM3570 when measuring 1 pF (1 MHz, 1 V) 100 times Reference value Measurement speed SLOW2 0.01% 36.3ms 0.04%, 4.8ms SLOW 0.07%, 1.5ms MID 0.5ms FAST 0.30% Variation [%] and measurement time [ms] ● Wide setting range for measurement voltage and current In addition to normal open-loop signal generation, this instrument enables measurement considering voltage/current dependence in constant voltage and constant current modes. The signal levels can be set over wide ranges, from 5 mV to 5 V, and from 10 μA to 50 mA (up to 1 MHz). (The setting range of measurement signal levels differs depending on the frequency and measurement mode.) ● DC bias can be generated internally Up to a 2.5 V DC bias can be applied and then measurement performed with just the unit. This is reassuring when measuring polar capacitors such as a tantalum capacitor. The charge impedance is 100 Ω. (The DC bias unit required with 3522-50 and 3532-50 is not needed for IM3570 within the bias voltage range of 0 to +2.5V. If a larger bias voltage is required, an external option, which is scheduled to be released in the future, is required.) ● High resolution with up to 7-digit display High-resolution measurement with full 7-digit display is possible. The number of display digits can be set from 3 to 7. ● Four-terminal probe allows for use at DC to 5 MHz The L2000 4-terminal probe (option) employs a 4-terminal structure to facilitate 50 Ω characteristic impedance and improved measurement accuracy, and is well suited to the IM3570. ● Measurement cable extendable to up to 4 meters Accuracy is guaranteed at the measurement cable lengths of 0, 1, 2, and 4 meters. This makes wiring automated machinery simple. (The frequency range for which accuracy is guaranteed differs depending on the cable length. The probe needs to be provided by the customer.) ● Longer stability Measurement accuracy is guaranteed for one year. Previous models required calibration every 6 months, but with this model the calibration interval has been extended to one year. ● Interval measurement ● Segment setting Up to 20 segments with a total of up to 801 points can be set for the sweep range. This is effective for evaluating multiple frequency ranges in detail. In order to, for example, confirm the temporal changes of an element from the response of a sensor, parameter time variations can be measured for up to 801 points at a specified interval (100 μs to 10,000s), and then the data can be displayed in a graph or list. ● Memory function Up to 32,000 measurement results can be stored in the memory of the instrument. The saved measurement results can be copied to a USB flash drive, and can also be acquired using a communication command. Interval setting screen 5 Link with computer via USB, LAN, RS-232C, or GP-IB Effective for Acquisition and Analysis of Measurement Data ● PC application Basic sof t wa re capable of f requency cha racter istics, level characteristics, and continuous measurement is provided. Connecting a PC to the RS-232C, USB, or LAN port on the rear panel enables you to easily operate the instrument from the PC and acquire data. The software includes simple command send functions that can be used to save effort in the measurement sequence and confirm interface command operations. ● Instrument mode indicators Indicators allow you to identify the operating state of the instrument even when the LCD display is off. ● Intuitive operation with touch panel A touch panel display with intuitive operation is inherited from previous models. Furthermore, the incorporation of a color LCD means the display is easy to view, and outstanding operability which ensures you intuitively know what to do helps improve work efficiency. MEAS: Measuring COMP/BIN: Comparator/BIN mode Measurement screen (LCR mode) Measurement parameter input screen Setting items of basic measurement conditions Measurement conditions such as the measurement frequency and measurement signal level can be changed while you monitor the measurement values. Frequency setting (numeric keypad input and up/down input) Saving and reading data via front-loading USB port Measurement results and settings can be saved to a commercially available USB flash drive connected to the front panel. (The USB port on the front panel is specifically for a USB flash drive. Batch save all measurement results to a USB flash drive after saving them to the internal memory of IM3570. Some USB flash drives may not be able to be used due to incompatibility issues.) Various measurement results and settings Save to USB flash drive External control from PC or PLC via USB, LAN, GP-IB, or RS-232C connection The rear panel is standard equipped with RS-232C, GP-IB, USB and LAN ports. (The USB port on the rear panel is specifically for connecting a PC.) Various functions of IM3570 can be controlled from a PLC or PC, and measurement results can be acquired. (Excluding turning the power on/off and configuring some interface settings.) Use of an interface suitable for automated machinery enables you to build the optimal measurement system. EXT I/O (handler interface) LAN USB (for connecting a PC) IM3570 rear panel RS-232C GP-IB 6 EXT I/O ● Handler (EXT I/O) interface The handler (EXT I/O) interface enables output of an end of measurement signal and measurement result signal, and input of signals such as a measurement trigger signal to control the measuring instrument. Each of the signal lines is isolated from the control circuit, and the structure is designed to protect against noise. Example of representative EXT I/O timing t0: Minimum time for trigger signal: 0.3 ms or longer *1 t1: Delay setting time from comparator and BIN judgment results to EOM (LOW): 0.04 ms or longer *1 t2: Minimum time from end of measurement to next trigger: 0.4 ms *1 t3: Time from trigger to response by circuit: 0.7 ms *1 t4: Minimum chuck time for which chuck can be switched with INDEX (LOW): 0.3 ms *1 t5: Measurement time: 0.5 ms *1 *1: When the measurement speed is FAST and the range is HOLD. Connectors Connectors to use (unit side) : 37-pin D-SUB female connector with #4-40 inch screws Compliant connectors : DC-37P-ULR (solder type) and DCSP-JB37PR (insulation-displacement type) For information on where to obtain connectors, consult your nearest HIOKI distributor. IM3570 specifications Measurement modes Measurement parameters Measurement range Display range LCR mode: Measurement with single condition Analyzer mode: Sweeps with measurement frequency and measurement level (Measurement points: 1 to 801, Measurement method: normal sweep or segment sweep, Display: List display or graph display) Continuous measurement mode: Measures under saved conditions continuously (maximum of 32 sets) Z Y θ Rs(ESR) Rp Rdc X G B Cs Cp Ls Lp D(tanδ) Q Impedance Admittance Phase angle Series-equivalent resistance = ESR Parallel-equivalent resistance DC resistance Reactance Conductance Susceptance Series-equivalent static capacitance Parallel-equivalent static capacitance Series-equivalent inductance Parallel-equivalent inductance Loss coefficient = tan δ (δ= delta) Q factor (Q = 1/D) 100 mΩ to 100 MΩ, 12 ranges (All parameters are determined according to Z ) Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp : ±(0.000000 [unit] to 9.999999G [unit] Absolute value display for Z and Y only θ : ±(0.000° to 999.999°) D : ±(0.000000 to 9.999999) Q : ±(0.00 to 99999.99) Δ % : ±(0.0000% to 999.9999%) Basic accuracy Z : ±0.08%rdg. θ: ±0.05° Measurement frequency 4Hz to 5MHz (10 mHz to 100 Hz steps) Measurement signal level Normal mode: V mode/CV mode: 5 mV to 5 Vrms (up to 1 MHz), 10 mV to 1 Vrms (1 MHz to 5 MHz), 1 mVrms steps CC mode: 10 μA to 50 mArms (up to 1 MHz), 10 μA to 10 mArms (1 MHz to 5 MHz), 10 μArms steps Low impedance high accuracy mode: V mode/CV mode: 5 mV to 1 Vrms (up to 100 kHz), 1 mVrms steps CC mode:10 μA to 100 mArms (100 mΩ and 1Ω ranges of up to 100 kHz), 10 μArms steps Output impedance Display No. of display digits setting Measurement time Measurement speed Normal mode: 100 Ω Low impedance high accuracy mode: 10 Ω 5.7-inch color TFT, display can be set to ON/OFF The number of display digits can be set from 3 to 7 (initial value: 6 digits) 0.5 ms (100 kHz, FAST, display OFF, representative value) FAST/MED/SLOW/SLOW2 DC bias measurement Normal mode: 0 VDC to 2.50 VDC (10 mV steps) Low impedance high accuracy mode: 0 VDC to 1.00 VDC (10 mV steps) DC resistance measurement Normal mode Measurement signal level: 100 mVDC to 2.5 VDC (10 mV steps) Low impedance high accuracy mode Measurement signal level: 100 mVDC to 1.00 VDC (10 mV steps) Comparator LCR mode: Hi/IN/Lo for first and third items Analyzer mode: Area judgment (Hi/IN/Lo for each point) Peak judgment (Hi/IN/Lo for local maximum and local minimum frequency and absolute values) BIN measurement 10 classifications and out of range for 2 items Compensation Residual charge protection function Trigger synchronous output function Averaging Interval measurement Panel loading/saving Memory function Printer Interfaces Operating temperature and humidity ranges Storage temperature and humidity ranges Power supply Dimensions and weight Accessory Open/short/load/cable length of 0 and 1 m/correlation compensation V= √ 10/C (C: Capacitance [F] of test sample, V = max. 400 V) Applies a measurement signal during analog measurement only 1 to 256 100 μs to 10,000 s, max. 801 points LCR mode: 30; Analyzer mode: 2; Compensation value: 128 Stores 32,000 data items to the memory of the instrument Prints measurement values and graphs (9670 option, etc. required) EXT I/O (handler), RS-232C, GP-IB, USB (Hi-Speed/FullSpeed), USB flash drive, LAN (10BASE-T/100BASE-TX) 0°C to 40°C, 80% RH or less, no condensation -10°C to 50°C, 80% RH or less, no condensation 90 to 264 V AC, 50/60 Hz, 150 VA max. Approx. 330 (W) x 119 (H) x 307 (D), approx. 5.8 kg Power cord x 1 7 IM3570 measurement accuracy Conditions The measurement accuracy is calculated based on the following equation. Temperature and humidity ranges: 23℃ ± 5℃, 80% RH or less (no condensation), at least 60 minutes after power turned on, after performing open and short compensation Basic accuracy (Z, θ) calculation expression 1 kΩ range and above: Accuracy = A + B × Bottom A: Basic accuracy of θ (± % deg.) B is the coefficient for the impedance of the sample A is the accuracy of R when DC (± % rdg.) B is the coefficient for the resistance of the sample [D: Measurement speed coefficient] FAST : 8, MED : 4, SLOW : 2, SLOW2: 1 10 × Zx -1 Range 300 Ω range and below: Range -1 Accuracy = A + B × Zx Zx is the actual impedance measurement value (Z) of the sample. Guaranteed accuracy range DC 100MΩ 8MΩ to 200MΩ 10MΩ 800kΩ to 100MΩ A=4 B=6 A=0.5 B=0.3 A=0.2 B=0.1 80kΩ to 10MΩ A=0.1 B=0.01 100kΩ 24kΩ to 1MΩ 30kΩ 8kΩ to 300kΩ A=0.1 B=0.01 10kΩ 2.4kΩ to 100kΩ A=0.1 B=0.01 3kΩ 800Ω to 30kΩ A=0.1 B=0.01 1kΩ 240Ω to 10kΩ A=0.1 B=0.01 A=0.1 B=0.02 300Ω 8Ω to 300Ω 10Ω 800mΩ to 10Ω A=0.2 B=0.15 1Ω 80mΩ to 1Ω A=0.3 B=0.3 100mΩ 1mΩ to 100mΩ ( ) ( ) [F: DC bias coefficient] VAC : AC signal voltage setting value [V] DC bias setting OFF : 1 10Ω range or below, DC bias setting ON : 2 × 1+ 0.1 , 4 × 1+ 0.1 (At VAC VAC minimum 100.01 kHz.) ( A=3 B=2 4 Hz to 99.9 Hz 100 Hz to 999.99 Hz A=6 A=5 B=5 B=3 A=3 A=2 B=2 B=2 A=3 A=2 A=0.8 A=0.8 A=0.4 A=0.3 A=0.3 A=0.3 A=0.3 A=0.3 A=0.3 A=0.3 A=0.3 A=0.2 A=0.3 A=0.2 A=0.4 A=0.2 A=0.5 A=0.3 A=2 A=1 A=10 A=6 B=1 B=0.5 B=0.08 B=0.08 B=0.01 B=0.01 B=0.01 B=0.01 B=0.01 B=0.01 B=0.02 B=0.01 B=0.02 B=0.01 B=0.02 B=0.01 B=0.2 B=0.1 B=1 B=0.6 B=10 B=6 A=0.5 A=0.4 A=0.3 A=0.2 A=0.2 A=0.1 A=0.2 A=0.1 A=0.2 A=0.1 A=0.2 A=0.1 A=0.2 A=0.1 A=0.3 A=0.15 A=0.4 A=0.3 A=0.6 A=0.5 A=3 A=2 B=0.3 B=0.2 B=0.05 B=0.02 B=0.01 B=0.01 B=0.005 B=0.003 B=0.01 B=0.005 B=0.005 B=0.002 B=0.01 B=0.005 B=0.02 B=0.01 B=0.05 B=0.03 B=0.3 B=0.2 B=3 B=2 A=0.5 B=0.3 A=0.4 B=0.2 A=0.3 B=0.05 A=0.2 B=0.02 A=0.15 B=0.01 A=0.1 B=0.01 A=0.12 B=0.005 A=0.08 B=0.003 A=0.12 B=0.005 A=0.08 B=0.002 A=0.12 B=0.005 A=0.08 B=0.002 A=0.1 B=0.005 A=0.08 B=0.002 A=0.08 B=0.02 A=0.05 B=0.01 A=0.3 B=0.05 A=0.15 B=0.03 A=0.4 B=0.3 A=0.25 B=0.2 A=3 B=3 A=2 B=1.5 ● Method of determining basic accuracy • Calculate the basic accuracy from the sample impedance, measurement range, and measurement frequency and the corresponding basic accuracy A and coefficient B from the table above. • The calculation expression to use differs for each of the 1 kΩ range and above and 300 Ω range and below. • For C and L, obtain basic accuracy A and coefficient B by determining the measurement range from the actual measurement value of impedance or the approximate impedance value calculated with the following expression. Zx (Ω) [E: Measurement cable length coefficient] fm: Measurement frequency [kHz] 0 m : 1 (DC to 5MHz), 1 m : 1.5 (DC to 5MHz), 2 m : 2 × 1+ fm (DC to 100kHz), 4 m : 4 × 1+ fm (DC to 10kHz) 100 100 ) ( ) [G: Temperature coefficient] t: Operating temperature When t is 18℃ to 28℃ : 1, When t is 0℃ to 18℃ or 28℃ to 40℃ : 1+ 0.1 × t-23 Basic accuracy 1MΩ [C: Level coefficient] V: Setting value (corresponds to when V mode) [V] 0.1 0.005V to 0.999V : 1 + (For measurements other than DCR, at 30kΩ range or below) V 0.3 (All DCR ranges, and 100kΩ range and above for 1+ V measurements other than DCR) 1V to 5V : 1 In the 1 kΩ range and above and 300 Ω range and below, the calculation expression of basic accuracy differs as shown below. For details, refer to the following calculation examples. Top A: Basic accuracy of Z (± % rdg.) B is the coefficient for the impedance of the sample Range Measurement accuracy = Basic accuracy × C × D × E × F × G ωL (H) (θ 90º) 1 (θ -90º) ωC (F) R (Ω) (θ 0º) (ω: 2 x π x Measurement frequency [Hz]) 1 kHz to 10 kHz B=2 B=2 10.01 kHz to 100 kHz 100.1 kHz to 1 MHz 1.001 MHz to 5 MHz A=8 A=3 B=4 B=2 * Set the accuracy to A=1 B=0.7 A=1 B=0.2 A=0.3 B=0.08 A=0.3 B=0.08 A=0.25 B=0.04 A=0.2 B=0.02 A=0.25 B=0.01 A=0.15 B=0.005 A=0.2 B=0.02 A=0.08 B=0.02 A=0.2 B=0.005 A=0.08 B=0.005 A=0.2 B=0.01 A=0.08 B=0.01 A=0.2 B=0.02 A=0.08 B=0.02 A=0.3 B=0.05 A=0.15 B=0.03 A=0.4 B=0.3 A=0.25 B=0.2 A=2 B=2 A=2 B=1.5 A=3 A=3 A=1 A=1 A=0.4 A=0.3 A=0.4 A=0.3 A=0.3 A=0.2 A=0.3 A=0.15 A=0.3 A=0.15 A=0.3 A=0.15 A=0.4 A=0.3 A=1 A=0.7 A=4 A=3 B=2 B=1 B=0.5 B=0.5 B=0.3 B=0.3 B=0.05 B=0.03 B=0.03 B=0.05 B=0.01 B=0.01 B=0.01 B=0.01 B=0.03 B=0.02 B=0.2 B=0.1 B=1 B=0.5 B=3 B=4 ( f [MHz] + 3 ) times 4 for 1.001 MHz or above. * * * * * * * * * A=2 A=2 A=2 A=2 A=2 A=2 A=1.5 A=1 A=1.5 A=1 A=1.5 A=1 A=1.5 A=1 A=2 A=2 A=3 A=3 B=1 B=1 B=0.5 B=0.3 B=0.1 B=0.1 B=0.2 B=0.2 B=0.02 B=0.03 B=0.01 B=0.01 B=0.05 B=0.05 B=1.5 B=1 B=3 B=2 ● Calculation example Impedance Zx of sample: 500 Ω (actual measurement value) Measurement conditions: When frequency 10 kHz and range 1 kΩ Insert coefficient A = 0.1 and coefficient B = 0.005 for the Z basic accuracy from the table above into the expression. Z basic accuracy = 0.1 + 0.005 × 10 × 500 -1 = 0.12 (± %rdg.) 103 Similarly, insert coefficient A = 0.08 and coefficient B = 0.002 for the θ basic accuracy, as follows: 10 × 500 -1 = 0.088 (± deg.) θ basic accuracy = 0.08 + 0.002 × 103 Guaranteed accuracy range (measurement signal level) The guaranteed accuracy range differs depending on the measurement frequency, measurement signal level, and measurement range. Range 100MΩ 10MΩ 1MΩ 100kΩ 30kΩ,10kΩ,3kΩ, 1kΩ,300Ω,10Ω 1Ω 100mΩ DC 1 V to 2.5 V 0.1 V to 2.5 V 0.1 V to 2.5 V *1 4 Hz to 99.9 Hz 100 Hz to 999.99 Hz 1 kHz to 10 kHz 10.01 kHz to 100 kHz 100.1 kHz to 1 MHz 1.001 MHz to 5 MHz 0.101 V to 5 V 0.501 V to 5 V 0.050 V to 5 V 0.101 V to 5 V 0.501 V to 5 V 0.050 V to 5 V 0.101 V to 5 V 0.501 V to 1 V 0.050 V to 5 V 0.101 V to 1 V 0.005 V to 5 V 0.050 V to 1 V 0.005 V to 2 V *2 0.101 V to 2 V *3 The above voltages are the voltage setting values correspond to when in V mode. 0.101 V to 5 V 0.501 V to 1 V 0.501 V to 5 V *3 *1 Guaranteed accuracy of 10 mΩ or above, *2 Guaranteed accuracy of 0.01 V to 5 V when DC bias, *3 Guaranteed accuracy of 10 mΩ or above and 1.001 V to 5 V when DC bias OPTION FOUR-TERMINAL PROBE L2000 DC to 5 MHz Characteristic impedance: 50 Ω 4-terminal structure Test sample dimensions: 5mm or less * The cable length is 1 m. ● Printer 9670 TEST FIXTURE 9262 DC to 5 MHz Print method Print width Print speed Power Dimensions Mass SMD TEST FIXTURE 9263 SMD TEST FIXTURE 9677 SMD TEST FIXTURE 9699 DC to 5 MHz Test sample dimensions: 1 mm (0.04 in) to 10 mm (0.39 in) Electrodes on side for SMD DC to 120 MHz Test sample dimensions: 3.5mm ±0.5mm (0.14in ±0.02in) Electrodes on bottom for SMD DC to 120 MHz Test sample dimensions: 1.0mm (0.04in) to 4.0mm (0.16in) wide, maximum 1.5mm (0.06in) high Thermal line dot 72 mm 47.5 mm/s AC Adapter 9671 or Battery Pack 9672 Approx. 119 × 77 × 174 mm Approx. 500 g Other High Performance HIOKI LCR Meters LCR HiTESTER 3522-50 (DC, 1mHz to 100kHz) LCR HiTESTER 3532-50 (42Hz to 5MHz) Printer operation requires RS-232C Cable 9638 and AC Adapter 9671, and battery operation requires Battery Pack 9672 and Battery Charger 9673. Basic accuracy: Z; ± 0.08% Fastest measurement time 5 ms Built-in comparator: Upper and lower limit, absolute value Print Example Higher frequency range: DC, 1mHz to 100kHz (3522-50) / 42Hz to 5MHz (3532-50) Fourteen parameters measured: Z , Y , θ, Rp(DCR*), Rs(ESR, DCR*), G, X, B, Cp, Cs, Lp, Ls, D(tan δ), Q (*3522-50 only) Interactive touch panel operation, Simultaneous setting and measurement Enlarged display function Printer output (with the optional PRINTER 9442) IMPEDANCE ANALYZER IM3570 (Standard accessories: power cord) Test fixtures are not supplied with the unit. Select an optional test fixture or probe when ordering. ■ Optional accessories FOUR-TERMINAL PROBE L2000 (1m) TEST FIXTURE 9262 (direct connection type) SMD TEST FIXTURE 9263 (direct connection type) SMD TEST FIXTURE 9677 (direct connection type) SMD TEST FIXTURE 9699 (direct connection type, For measuring SMDs with electrodes on the bottom) GP-IB CONNECTION CABLE 9151-02 (2 m/78.74”) PRINTER 9670 (Non CE) AC ADAPTER 9671 (AC100 to 240V, Non CE) RS-232C CABLE 9638 (25 pin-9 pin, 1.5m, for 9670 connectors) RECORDING PAPER 9237 (80 mm × 25 m, 4 rolls) HIOKI (Shanghai) Sales & Trading Co., Ltd. : 1608-1610 Shanghai Times Square Office, 93 Huai Hai Zhong Road, Shanghai, P.R.China POSTCODE: 200021 TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360 http://www.hioki.cn / E-mail: [email protected] HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 http://www.hioki.co.jp / E-mail: [email protected] HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 http://www.hiokiusa.com / E-mail: [email protected] DISTRIBUTED BY Beijing Office : TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090 E-mail: [email protected] Guangzhou Office : TEL +86-20-38392673/2676 FAX +86-20-38392679 E-mail: [email protected] HIOKI INDIA PRIVATE LIMITED : Khandela House, 24 Gulmohar Colony Indore 452 018 (M.P.), India TEL +91-731-4223901, 4223902 FAX +91-731-4223903 http://www.hioki.in / E-mail: [email protected] All information correct as of Jul. 23, 2010. All specifications are subject to change without notice. IM3570E1-07E-05K