2 System & Application Software Enhanced Efficiency in System Measurements Efficient testing can be consistently performed using a controller (custom-built) to conduct protective grounding, insulation resistance, and voltage withstand testing all at once. Contact us for system upgrades. 3157-01 AC GROUNDING HiTESTER ● Measurement current: Max. 31 A ● Resistance measurement range: 0 to 1.800 W 3153 AUTOMATIC INSULATION / WITHSTANDING HiTESTER ● Withstanding test : Testing voltage; 0.2 to 5.00 kV AC 500 VA : Measurement range; Current :0.01 to 100.0 mA ● Insulation test : Testing voltage; 500 V DC / 1000 V DC : Measurement range; 0.1 to 9999 MΩ Outline of the 9267 SAFETY TEST DATA MANAGEMENT SOFTWARE ■ Test Types and Corresponding Test Instrument • Insulation Withstand Test: 3153/3159/3158 (withstand voltage only) • Protective Conductivity Test: 3157 • Live Line Testing: 3332 ■ Test Sequence Operation The above three tests can be performed in any desired sequence. However, the same test should not be performed more than once. Also, at least one of the tests must be performed. ■ Interface for connecting test instruments to the PC RS-232C only (Multiple test instrument can be connected through a commonly available multiplexer.) ■ Test Data Recording Test results are recorded as a specified text file (in CSV format). ■ Connection Switching Function Connections can be switched prior to each test by sending commands to the PLC (programmable logic controller). ■ ID Number Management ID numbers can be managed for test targets. Automatic ID Incrementing ID Number Digit Count Setting ID Header Appending Function ■ 3153 Program Setting A program setting screen is provided for the 3153. Program setting can be saved as or loaded from text files. [Program Setting] [Load Data] [Save Program Setting as Text]