NetSpan™ FBD Series, Fiber Distribution Kit – Closed Architecture

NetSpan™ FBD Series, Fiber Distribution Kit – Closed
Architecture
Description and Installation Manual, 631-200-074 (Issue A, January 8, 2014)
Specification Number: F1010627, F1010628
NetSpan™ FBD Series, Fiber Distribution Kit – Closed Architecture
Description and Installation Manual, 631-200-074 (Issue A, January 8, 2014)
Table of Contents
About this Document ............................................................................................................................................ 1
Purpose .................................................................................................................................................................. 1
Other Documentation ............................................................................................................................................. 1
Description ........................................................................................................................................................... 1
Installation ............................................................................................................................................................ 1
You Will Need ......................................................................................................................................................... 1
Procedure ............................................................................................................................................................... 1
Fiber Cable Guidelines ........................................................................................................................................... 2
You Will Need ......................................................................................................................................................... 2
Procedure ............................................................................................................................................................... 2
NetPerform™ Optimization Services ..................................................................................................................... 7
Spec. No: F1010627, F1010628
Code: 631-200-074
Issue A, January 8, 2014
NetSpan™ FBD Series, Fiber Distribution Kit – Closed Architecture
Description and Installation Manual, 631-200-074 (Issue A, January 8, 2014)
About this Document
When installed, the kit allows a BD4 or BD5 Pedestal to:
Purpose
This practice provides a description of the Fiber Distribution Kit
(F1010627, F1010628) for BD4 and BD5 Pedestals as well as
installation instructions. Refer to Figure 1.
•
hold up to ten splice trays (up to 5 inches wide by 10.5
inches tall, a total stack of up to 2.5 inches per side) and
•
store over 12 feet of fiber slack (144-fiber loose tube).
Installation
Figure 1. Fiber Distribution Box
You Will Need
To install the kit in a BD4 or BD5 Pedestal, you will need:
•
a 216-type tool or a socket wrench with 3/8-inch and
7/16-inch sockets.
Procedure
Perform the following steps to install a Fiber Distribution Kit in a
BD4 or BD5 Pedestal:
1.
Unpack the kit, and verify that it contains the appropriate
parts, as shown in Figure 2.
Figure 2. Components of the Fiber Distribution Kit
UPCBD Fiber Enclosure
Internal View
Feeder Side
Internal View
Drop Side
Other Documentation
For more information on the BD4 and BD5 Pedestals, refer to the
practice 631-200-015, UPCBD-Style Pedestals Installation
Instructions. Refer to other company and local practices for the
correct methods, tools, and materials to be used in performing
procedures not specifically described within this practice.
Note: The information contained in this practice may not be suitable
in all situations.
Description
This kit allows a BD4 or BD5 Pedestal to be converted for fiber
optics splicing and slack storage. This minimizes the need to stock
multiple pedestal types, as the same type of pedestal can now be
used for copper or fiber distribution. This kit can also be installed
in the field, increasing the flexibility of your existing Outside Plant
(OSP) network.
Spec. No: F1010627, F1010628
[1 of 7]
1/4-20
Hex Bolt
Fiber Box
Two 1/4-20 x 0.80
Long Cup SEMS Bolts
2.
Remove the front cover from the pedestal by loosening
the upper cover cup SEMS locking bolt. See Figure 3.
3.
Remove any existing bracket or mounting plate from the
pedestal.
4.
Remove the upper strap holder and lower knockout from
the pedestal as shown in Figure 3.
5.
Remove the front cover from the fiber box by loosening
the one (1) 1/4-20 Hex bolt. See Figure 2.
6.
Use the two 1/4-20 x 0.80 long cup SEMS bolts from the
kit to attach the fiber box to the pedestal, as shown in
Figure 4.
Code: 631-200-074
Issue A, January 8, 2014
NetSpan™ FBD Series, Fiber Distribution Kit – Closed Architecture
Description and Installation Manual, 631-200-074 (Issue A, January 8, 2014)
Figure 3. Strap Holder and Knockout to be Removed from Pedestal
Remove this
strap holder.
3.0 inches
(7.6 cm)
Remove this
strap holder.
3.0 inches
(7.6 cm)
18.63 inches
(47.3 cm)
18.63 inches
(47.3 cm)
Remove this
7/16” round
knockout.
Pedestal’s Upper
Cover Cup SEMS
Locking Bolt
BD4
Remove this
7/16” round
knockout.
Pedestal’s Upper
Cover Cup SEMS
Locking Bolt
Front View
of BD4
BD5
Front View
of BD5
Fiber Cable Guidelines
Figure 4. Attaching the Fiber Box to the Pedestal
You Will Need
To bring fiber cable into a modified BD4 or BD5 Pedestal, you will
need:
1/4-20 x 0.80
Long Cup SEMS Bolt
•
#2 Phillips screwdriver,
•
a 216-type tool (or 3/8-inch socket wrench or driver), and
•
an OSP cable jacket stripper.
Procedure
To bring fiber cable into a modified BD4 or BD5 Pedestal, perform
the following steps:
1.
Fiber Box
(Front Cover Removed)
1/4-20 x 0.80
Long Cup SEMS Bolt
Make sure that the fiber cable loop is of the proper length
to ensure the amount of slack buffer tube storage
desired. The length will depend on the type of pedestal
you have and the number of loops of fiber cable buffer
tubes you plan to store on the fiber plate. The proper
cable lengths are listed in Table 1. These lengths are
from the ground line back to the ground line, as shown in
Figure 5.
BD4 or BD5
Spec. No: F1010627, F1010628
[2 of 7]
Code: 631-200-074
Issue A, January 8, 2014
NetSpan™ FBD Series, Fiber Distribution Kit – Closed Architecture
Description and Installation Manual, 631-200-074 (Issue A, January 8, 2014)
Table 1.
Figure 6. Stripping a Loose Tube Feeder Cable
Fiber Cable and Buffer Tube Loop Length
Total Linear Feet (+/- 3 Inches)
Pedestal
Type
For 3 Loops
of Slack Storage
For 4 Loops
of Slack Storage
BD4
11.0 Feet
(335 cm)
14.0 Feet
(427 cm)
BD5
12.0 Feet
(366 cm)
15.0 Feet
(457 cm)
Buffer
Tubes
2-1/2 inches
(6 cm)
Strength
Member
Buffer
Tubes
10 inches for
UPCBD4 pedestal
or 16 inches for
UPCBD5 pedestal
(25 cm or 41 cm)
Figure 5. Fiber Cable Loop or Buffer Tube Lengths
Ground
Line
Figure 7. Stripping a Ribbon Feeder Cable
Ribbon
Fiber
Central
Tube
Strength
Members
Ribbon
Fiber
6 inches
2-1/2 inches (15 cm)
(6 cm)
10 inches for
UPCBD4 pedestal
or 16 inches for
UPCBD5 pedestal
(25 cm or 41 cm)
Ground
Line
4 inches
(10 cm)
Figure 8. Stripping a Drop Cable
6 feet 6 inches
(2 m) minimum
Ground
Line
2.
Buffer
Tube
Stripping the cable’s outer jacket per local practices;
b.
Stripping the end of the fiber cable; and
c.
Stripping a drop cable.
Strength
Members
Ground
Line
Note: Refer to Figure 6, Figure 7 and Figure 8 for details on
the loose tube feeder cables, ribbon feeder cables
and drop cables, respectively.
Spec. No: F1010627, F1010628
2-1/2 inches
(6 cm)
10 inches for
UPCBD4 pedestal
or 16 inches for
UPCBD5 pedestal
(25 cm or 41 cm)
Prepare the fiber cable loop by:
a.
Buffer
Tube
[3 of 7]
3.
Secure the fiber cable loop per local practices.
(See Figure 9 and Figure 10.)
Code: 631-200-074
Issue A, January 8, 2014
NetSpan™ FBD Series, Fiber Distribution Kit – Closed Architecture
Description and Installation Manual, 631-200-074 (Issue A, January 8, 2014)
Figure 9. Securing the Fiber Cable Loop
Fiber Cable
Fiber Cable
Buffer Tubes and
Strength Member
(see Figures 9 and 10)
Secure fiber cables
at these locations.
Cable
Secure fiber cables
at these locations.
16.0 inches
(41 cm)
10.0 inches
(25 cm)
4.0 inches
(10 cm)
4.0 inches
(10 cm)
Ground Line
Ground Line
Side View of BD4
Side View of BD5
Figure 10. Securing Cables to Fiber Plate
Detail A
Loosen screws on clamp plate,
insert cable central strength member
(if applicable) into clamp template,
tighten clamp plate screw.
Detail B
Secure jacketed cable to fiber plate
via cable ties or hose clamp (not provided).
see Detail A
4.
Perform OSP cable breakout per local practices.
5.
Route the buffer tube(s) that are dedicated to be spliced
on the drop side by looping over from feeder side to the
drop side at the top of the closure.
6.
Wrap unused buffer tube around the spool on the fiber
plate (shown in Figure 11).
7.
Splice the fibers per local practices.
8.
Use the Velcro straps to secure the splice tray in the
location indicated in Figure 12.
9.
Close fiber box.
10. Close the pedestal.
see Detail B
Side View
Fiber Box
Spec. No: F1010627, F1010628
[4 of 7]
Code: 631-200-074
Issue A, January 8, 2014
NetSpan™ FBD Series, Fiber Distribution Kit – Closed Architecture
Description and Installation Manual, 631-200-074 (Issue A, January 8, 2014)
Figure 11. Spool on Fiber Plate
Figure 12. Position for Splice Tray
Velcro Straps
spool
Splice Tray
Mounts Here
Side View
Fiber Box
Spec. No: F1010627, F1010628
[5 of 7]
Code: 631-200-074
Issue A, January 8, 2014
NetSpan™ FBD Series, Fiber Distribution Kit – Closed Architecture
Description and Installation Manual, 631-200-074 (Issue A, January 8, 2014)
Table 2.
Accessories and Replacement Parts
Part Number
Description
Type of Part*
F003205
5” CAN Wrench 216 Type Tool
AC
F1010586
Fiber Splice Tray
AC
F600490
1/4-20 x 0.8” Cup SEMS Locking Bolt - Closure to Pedestal
RP
129904
Feeder Side Cable Grommet
RP
130453
Drop Side Cable Grommet
RP
P34225
10-32 x 0.75” Hex Washer Head Screw Cover Locking Bolt
RP
141595
Feeder or Drop Side CSM Central Strength Member Clamp Plate
RP
132210
Wire Retaining Guide 1-1/2” diameter P Clip
RP
* Type of Part
Accessory = AC [1]
Replacement Part = RP [3]
Spec. No: F1010627, F1010628
[6 of 7]
Code: 631-200-074
Issue A, January 8, 2014
NetSpan™ FBD Series, Fiber Distribution Kit – Closed Architecture
Description and Installation Manual, 631-200-074 (Issue A, January 8, 2014)
NetPerform™ Optimization Services
At Emerson Network Power, we understand the importance of reliable equipment – it’s critical to both your business and your bottom
line. That is why we offer a wide array of services to meet all of your network infrastructure needs.
Customer Service (Pre-Shipment)
Email
[email protected]
Phone
1.800.800.1280 option 2
Pricing and availability [1], purchase orders, expediting requests
and order tracking. Ask for your company’s dedicated Customer Service
Associate.
Customer Support Center (Post-Shipment)
Email
[email protected]
Phone
1.956.661.6867
After an order has shipped, contact our Customer Support Center
with related questions, concerns or claims.
Account Management
Email
[email protected]
Phone
1.800.800.1280 option 3
Provides quotes and bid responses for custom configured [2] DC power
systems and outside plant enclosures for customers and channel partners
(Reps, VARs & Distributors).
Spare Parts
Email
[email protected]
[email protected]
Phone
1.800.800.1280 option 5
Pricing and purchase orders for spare parts [3], including but not limited to
breakers, cables, fuses, rectifier fans, misc. breaker and fuse panels,
enclosure fans, doors and switches, etc.
DC Power Depot Repair
Email
[email protected]
Phone
1.800.800.1280 option 6
Creates and processes RMAs for depot repair and refurbishment.
Determines repair and refurbishment lead times and pricing based on
warranties/contractual agreements. Provides repair shipping information
and status.
Technical Support
Email
[email protected]
[email protected]
Phone
1.800.800.5260
[1]
[2]
[3]
Answers technical product and system questions; determines status of
warranties and contractual agreements for repair.
Contact Customer Service for products and accessories.
Contact Account Management for custom-configurations.
Contact DC Power Spare Parts for parts.
For More Information
To learn more about service offerings from Emerson Network Power, please contact your sales representative,
call 1-800-800-1280 option 7, email [email protected] or visit EmersonNetworkPower.com/EnergySystems.
Spec. No: F1010627, F1010628
[7 of 7]
Code: 631-200-074
Issue A, January 8, 2014
NetSpan™ FBD Series, Fiber Distribution Kit – Closed Architecture
Description and Installation Manual, 631-200-074 (Issue A, January 8, 2014)
The information contained in this document is subject to change without notice and may
not be suitable for all applications. While every precaution has been taken to ensure the
accuracy and completeness of this document, Emerson Network Power, Energy Systems,
North America, Inc. assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Refer to other local
practices or building codes as applicable for the correct methods, tools, and materials to
be used in performing procedures not specifically described in this document.
The products covered by this instruction manual are manufactured and/or sold by Emerson
Network Power, Energy Systems, North America, Inc. This document is the property of
Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and
proprietary information owned by Emerson Network Power, Energy Systems, North
America, Inc. Any copying, use or disclosure of it without the written permission of Emerson
Network Power, Energy Systems, North America, Inc. is strictly prohibited.
Names of companies and products are trademarks or registered trademarks of the
respective companies. Any questions regarding usage of trademark names should be
directed to the original manufacturer.
EmersonNetworkPower.com/EnergySystems (North America)
EmersonNetworkPower.eu/EnergySystems (EMEA)
© Emerson Network Power, Energy Systems, North America, Inc. 2014.
Business-Critical Continuity ™, Emerson Netw ork Power™, the Emerson Netw ork Power logo , Emer son™ and Conside r it Sol ved are serv ice marks and
trademar ks of Emer son Electric Co. EnergyMaster ™, eSur e™, NetPer form™, NetR each ™, NetSpan™, NetSure ™ and NetXtend ™ are tradema rks of Emerson
Network Power, Energy Syste ms, Nor th America, Inc . Any other product, brand, or company names or logos are the property of the respective owner.
Spec. No: F1010627, F1010628
While every precaution has been taken to ensure accuracy and
completeness herein, Emerson Electric Co. assumes no responsibility,
and disclaims all liability, for damages resulting from use of this
information or for any errors or omissions. Specifications subject to
change without notice.
Code: 631-200-074
Issue A, January 8, 2014