P-511-590(V:1) PD121XL4 Version :1.0 TECHNICAL MODEL SPECIFICATION NO. : PD121XL4 The content of this information is subject to be changed without notice. Please contact PVI or its agent for further information. Customer’s Confirmation Customer Date By PVI’s Confirmation FOR MORE INFORMATION: AZ DISPLAYS, INC. 75 COLUMBIA, ALISO VIEJO, CA 92656 Http://www.AZDISPLAYS.com The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:1 P-511-590(V:1) Revision History Rev. 0.1 0.2 0.3 0.4 1.0 PD121XL4 Eng. Issued Date Revised Contents Sarah Huang July 18,2008 Preliminary Sarah Huang Sep 02,2008 Modify Page 5 4. Mechanical Drawing of TFT-LCD Module Modify Page 16 13. Optical Characteristics Horizontal View angle from 70 to 75 Vertical View angle from 50/40 to 75/45 Contrast Ratio from 400 to 600 nit Sarah Huang Nov 18,2008 Modify Page 5 4. Mechanical Drawing of TFT-LCD Module Sarah Huang Feb 5, 2009 Modify Page 5,6 4. Mechanical Drawing of TFT-LCD Module Sarah Huang Jan 07, 2010 Modify Page 7 5. Input / Output Terminals Modify Page 16 13. Optical Characteristics Vertical View angle from 75/45 to 65/55 Uniformity from 75% to 70% Add Page 21 16. Packing Diagram The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:2 P-511-590(V:1) TECHNICAL SPECIFICATION PD121XL4 CONTENTS NO. ITEM PAGE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Cover Revision History Contents Application Features Mechanical Specifications 1 2 3 4 4 4 5 7 8 9 10 11 12 13 15 16 19 20 21 Mechanical Drawing of TFT-LCD Module Input / Output Terminals Absolute Maximum Ratings Electrical Characteristics Pixel Arrangement Display Color and Gray Scale Reference Block Diagram Interface Timing Power On Sequence Optical Characteristics Handling Cautions Reliability Test Packing Diagram The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:3 P-511-590(V:1) PD121XL4 1. Application The PD121XL4 is a 12.1” TFT-LCD module with LED B/L and a 20-pin LVDS interface. This module supports 1024 x768 XGA mode and displays 262,144 colors. This module can apply TFT-LCD monitor, TV, Factory application, Amusement Vehicle, and so on. 2. Features - Wide viewing angle - Fast response time - High color saturation - XGA (1024 x768 pixels) resolution - Wide operating temperature - DE (Data Enable) mode - LVDS (Low Voltage Differential Signaling) interface - RoHS Compliance 3. Mechanical Specifications Parameter Screen Size Display Format Display Colors Active Area Pixel Pitch Pixel Configuration Outline Dimension Weight Back-light Surface treatment Display mode Gray scale inversion direction Specifications 12.1 (diagonal) 1024ͪ(R, G, B)ͪ768 262,144 245.76(H)Ø184.32(V) 0.240(H)Ø0.240(V) RGB Vertical Stripe 260.5(W)Ø 204(H)Ø 7.5(typ.) (D) 473+20 54-LED Anti-glare Normally White 12 O’clock Unit inch dot mm mm mm g Note 13-2 The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:4 P-511-590(V:1) PD121XL4 4. Mechanical Drawing of TFT-LCD Module The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:5 P-511-590(V:1) PD121XL4 The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:6 P-511-590(V:1) PD121XL4 5. Input / Output Terminals 5-1) TFT-LCD Panel Driving Connector type: DF19K-20P-1H CN1 Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Interface connector User side connector Symbol VSS VDD1 VDD2 NC NC NC NC RIN0RIN0+ VSS RIN1RIN1+ VSS RIN2RIN2+ VSS RCLKINRCLKIN+ VSS VSS Hirose/DF19L-20P-1H or equivalent Hirose/DF19G-20S-1C or equivalent Function Ground Power Supply: +3.3V Power Supply: +3.3V NC NC NC NC LVDS Negative data signal (-) LVDS Positive data signal (+) Ground LVDS Negative data signal (-) LVDS Positive data signal (+) Ground LVDS Negative data signal (-) LVDS Positive data signal (+) Ground LVDS Negative clock signal (-) LVDS Positive clock signal (+) Ground Ground Remark Tx pin #48 Tx pin #47 Tx pin #46 Tx pin #45 Tx pin #42 Tx pin #41 Tx pin #40 Tx pin #39 5-2) Backlight driving Connector type: JST BHSR-02VS-1, PIN No 2 pin Pin No 1 2 Symbol + - Description Input terminal (Anode) Input terminal (Cathode) Remark Wire color: Red Wire Color: Black The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:7 P-511-590(V:1) PD121XL4 5-3) LVDS Interface LVDS Transmitter: THC63LVDM83A or equivalent 6. Absolute Maximum Ratings: The followings are maximum values, which if exceeded, may cause faulty operation or damage to the unit. GND=0V,Ta=25к Parameters Symbol MIN. MAX. Unit Remark Logic Power Supply VDD VSS-0.3 +4.0 V Logic Input Voltage VIN VSS-0.3 VDD+0.3 V Note 6-1 Note 6-1: Permanent damage to the device may occur if maximum values are exceeded. Function operation should be restricted to the conditions described under Normal Operating Conditions. The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:8 P-511-590(V:1) PD121XL4 7. Electrical Characteristics 7-1) Recommended Operating Conditions: Ta=25 ± 2к Value Unit Note Min. Typ. Max. Power Supply Voltage VDD 3.0 3.3 3.6 V Note 7-1 Power Supply Current IDD 280 485 mA Power Consumption PDD 0.9 1.6 W Note 7-2 LVDS differential voltage VIDʳ -100 +100 mV LVDS common input voltage Vic 1.2 V Note7-1: The module is recommended to operate within specification ranges listed above for normal function. Note 7-2: PDD=VDD ͪ IDD Parameter Symbol 7-2) Recommended driving condition for LED backlight: Ta = 25к Remark Note 7-3 Note 7-4 Note 7-3/7-5 Parameter Symbol Min TYP MAX Unit Supply voltage of LED backlight VLED1 9.9 (10.8) V Supply current of LED backlight ILED1 20 mA Backlight Power Consumption PLED 3.56 (3.89) W Note 7-3: ILED = 20mA, Constant Current. Note 7-4: The LED driving condition is defined for each LED module. (3 LED Serial) Input current = 360mA Note 7-5: PLED = VLED1 * ILED1 +VLED2 * ILED2 +………+VLED17 * ILED17 +VLED18 * ILED18 The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:9 P-511-590(V:1) PD121XL4 8. Pixel Arrangement R G B RG BR G B R GB RG B R GB 1 st Line RG B R G B 2 nd Line RG B 3 rd Line 1 st Pixel 1024th Pixel 1 Pixel = R G B R G B 765 th Line RG BR G B RG B 767 th Line R G B RG B RG B 768 th Line R G B R G B The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:10 P-511-590(V:1) PD121XL4 9. Display Color and Gray Scale Reference Note 9-1: 0: Low Level Voltage, 1: High Level Voltage The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:11 P-511-590(V:1) PD121XL4 10. Block Diagram 10-1) TFT-module Block Diagram RIN1(+/-) RCLKIN (+/-) VDD INPUT CONNECTOR RIN2(+/-) VSS VLED LVDS INPUT / TIMING CONTROLLER SCAN DRIVER IC RIN0(+/-) TFT LCD PANEL (1024xR.G.Bx768) DATA DRIVER IC DC/DC CONVERTER & REFERENCE VOLTAGE LED CONNECTOR BACKLIGHT UNIT The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:12 P-511-590(V:1) PD121XL4 11. Interface Timing 11-1) The 12.1” XGA LCM is operated by the only DE mode (LVDS Transmitter Input) 11-2) LVDS Rx interface timing parameter The specification of the LVDS Rx interface timing parameter The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:13 P-511-590(V:1) PD121XL4 11-3) Signal Timing Waveforms of Interface Signal (DE Mode) A) Vertical Timing Waveforms B) Horizontal Timing Waveforms The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:14 P-511-590(V:1) PD121XL4 12. Power On Sequence To prevent a latch-up or DC operation of the LCD module, the power on/off sequence shall be as shown in below Note 12-1: When the power supply VDD is 0V, keep the level of input signals on the low or keep high impedance. Note 12-2: Do not keep the interface signal high impedance when power is on. Note 12-3: Back Light must be turn on after power for logic and interface signal are valid. The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:15 P-511-590(V:1) PD121XL4 13. Optical Characteristics 13.1) Specification: Ta=25к Parameter Horizontal Viewing Angle Vertical Contrast Ratio Response Rise time Fall Brightness LED Life Time White Chromaticity Uniformity Cross Talk Ratio Symbol Condition MIN. TYP. MAX. Unit Remarks Ӱ 70 75 deg Ӱ 60 65 deg Note 13-2 CRЇ10 (to 12 o’clock) Ӱ 50 55 deg (to 6 o’clock) Ӱ=0̓ CR 500 600 Note 13-3 Tr 10 20 ms Ӱ=0̓ Note 13-5 20 40 ms Tf Ӱ=0q/ӽ=0 400 550 L cd/ф Note 13-1 20000 30000 hrs Note 13-4 Ӱ=0q/ӽ=0 0.26 0.31 0.36 x Note 13-1 Ӱ=0q/ӽ=0 0.29 0.34 0.39 y U 65 70 % Note 13-6 CTK 3.5 % Note 13-7 Note 13-1: Topcon BM-5A or BM-7 fast luminance meter 1̓field of view is used in the testing. Note 13-2: The definitions of viewing angles are as follow Note 13-3: The definition of contrast ratio CR Luminance when Testing point is White Luminance when Testing point is Black Note 13-4: The “LED Life time “ is defined as the module brightness decrease to 50% original Brightness that the ambient temperature is 25к and ILED =360mA. The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:16 P-511-590(V:1) PD121XL4 Note 13-5: Definition of Response Time Tr and Tf White Black White 100% 90% Brightness 10% 0% Tr Tf Note 13-6: The uniformity of LCD is defined as The Minimum Brightness of the 9 testing Points U= The Maximum Brightness of the 9 testing Points Luminance meter: BM-5A or BM-7 fast (TOPCON) Measurement distance: 500 mm +/- 50 mm Ambient illumination: < 1 Lux Measuring direction: Perpendicular to the surface of module The test pattern is white (Gray Level 63). 25% 50% 75% 25% 50% 75% The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:17 P-511-590(V:1) PD121XL4 Note 13-7: Cross Talk (CTK) = ~YA-YB~ YA ͪ100% YA: Brightness of Pattern A YB: Brightness of Pattern B Luminance meter: BM 5A (TOPCON) Measurement distance: 500 mm +/- 50 mm Ambient illumination: < 1 Lux Measuring direction: Perpendicular to the surface of module Pattern A Pattern B (Gray Level 31) (Gray Level 31, central black box exclusive) YA YB 1/3 1/3 1/3 1/3 1/3 1/3 Black : Measuring Point (A and B are at the same point.) (Gray Level 0) The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:18 P-511-590(V:1) PD121XL4 14. Handling Cautions 14-1) Mounting of module a) Please power off the module when you connect the input/output connector. b) Polarizer which is made of soft material and susceptible to flaw must be handled carefully. c) Protective film (Laminator) is applied on surface to protect it against scratches and dirt. d) Please following the tear off direction as figure 14-1 to remove the protective film as slowly as possible, so that electrostatic charge can be minimized. 14-2) Precautions in mounting a) When metal part of the TFT-LCD module (shielding lid and rear case) is soiled, wipe it with soft dry cloth. b) Wipe off water drops or finger grease immediately. Long contact with water may cause discoloration or spots. c) TFT-LCD module uses glass which breaks or cracks easily if dropped or bumped on hard surface. Please handle with care. d) Since CMOS LSI is used in the module. So take care of static electricity and earth yourself when handling. 14-3) Adjusting module a) Adjusting volumes on the rear face of the module have been set optimally before shipment. b) Therefore, do not change any adjusted values. If adjusted values are changed, the specifications described may not be satisfied. 14-4) Others a) Do not expose the module to direct sunlight or intensive ultraviolet rays for many hours. b) Store the module at a room temperature place. c) The voltage of beginning electric discharge may over the normal voltage because of leakage current from approach conductor by to draw lump read lead line around. d) If LCD panel breaks, it is possibly that the liquid crystal escapes from the panel. Avoid putting it into eyes or mouth. When liquid crystal sticks on hands, clothes or feet. Wash it out immediately with soap. e) Observe all other precautionary requirements in handling general electronic components. f) Please adjust the voltage of common electrode as material of attachment by 1 module. Figure 14-1 the way to peel off protective film The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:19 P-511-590(V:1) PD121XL4 15. Reliability Test No 1 2 3 4 5 6 Test Item High Temperature Storage Test Low Temperature Storage Test High Temperature Operation Test Low Temperature Operation Test High Temperature & High Humidity Operation Test Thermal Cycling Test (non-operating) 7 Vibration Test (non-operating) 8 Shock Test (non-operating) 9 Electrostatic Discharge Test (Operation) Test Condition Ta = +80к, 240 hrs Ta = -40к, 240 hrs Ta = +70к, 240 hrs Ta = -30к, 240 hrs Ta = 60к, 90%RH, 240 hrs -30к(0.5hour) Ш+70к(0.5hour), 100Cycles FrequencyΚ10 ~ 57 HZ , AmplitudeΚ0.15 mm,58~500Hz, 1G Sweep time: 11 min Test Period: 3 hrs (1 hr for each direction of X, Y, Z) 80G, 6ms, X,Y, Z 1 times for each direction C=150pF,R=330Ө Contact=±8KV Air=±15KV 10 times/terminal Ta: ambient temperature [Criteria] In the standard conditions, there is not display function NG issue occurred. (including : line defect ,no image). All the cosmetic specification is judged before the reliability stress. The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:20 P-511-590(V:1) PD121XL4 16. Packing Diagram The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:21