WIRE WOUND CHIP INDUCTORS SWI1008HQ SERIES

Wire Wound Chip Inductors
SWI1008HQ Series
INTRODUCTION
The SWI series are wire wound chip inductors widely used in the communication applications such as
cellular phones, cable modem, ADSL, repeaters, Bluetooth, and other electronic devices. The wire
wound inductors advance in higher self resonate frequency, better Q factor, and much more stable
performance. The HQ type offer higher Q factor and the current handling has also been improved with
significantly lower DCR value. Precious tolerance of 2% is available.
FEATURES
Operating temperature -40 to +125°C for ceramic series.
Excellent solderability and resistance to soldering heat.
Suitable for reflow soldering.
High reliability and easy surface mount assembly.
Wide range of inductance values are available for flexible needs.
PART NUMBER
SWI 1008 HQ
1
1
Product Type
2
Chip Dimension
Size
(inch)
mm
SWI 1008
2520
2
Length (L)
(inch)
mm
3
12N G 4
5
Width (W)
(inch)
mm
(0.098 ± 0.008) (0.080 ± 0.008)
2.60 ± 0.20
2.10 ± 0.20
□□
6
Thickness (T)
(inch)
mm
Terminal (S)
(inch)
mm
(0.063 ± 0.008) (0.020 ± 0.004)
1.70 ± 0.20
0.50 ± 0.10
3
Material Type
HQ : High Q type
4
Inductance Value
10N = 10nH R10 = 100nH
5
Tolerance
G = ±2%
6
Internal Code
J = ±5%
1
K = ±10%
(t1 )
(Ref.)
mm
0.70
Wire Wound Chip Inductors
SWI1008HQ Series
1
Scope
This specification applies to fixed inductors of the following types used in electronic
equipment :
*HQ Type :
2
For lower inductance with high Q factor at high frequency and
stable circuit requirement.
Construction
*Configuration
& Dimension : Please refer to the attached figures and tables.
*Terminals
3
: Consist of Ag alloy followed by Nickel, then Au platting for easier
soldering.
Operating Temperature Range
Operating Temperature Range is the scope of ambient temperature at which the inductor can
be operated continuously at rated current.
*Temp. Range : Ceramic material : -40°C ~ +125°C
4
Ingredient of terminals electrode
3rd Layer
Ceramic Type :
2nd Layer
1st Layer : Ag
1st Layer
2nd Layer : Nickel (Ni)
Termination
3rd Layer : Gold (Au)
5
Characteristics
Standard Atmospheric Conditions
Unless otherwise specified, the standard range of atmospheric conditions for making
measurements and tests are as follows:
Ambient Temperature : 25°C ± 2°C
Relative Humidity
: 60% to 70%
Air Pressure
: 86Kpa to 106Kpa
2
Wire Wound Chip Inductors
SWI1008HQ Series
Temperature Profile
1
Reflow Temperature Profile
(Temperature of the mounted parts surface on the printed circuit board)
Recommended Peak Temperature : 250℃ Max
250℃ up /within 10secs
Max. Reflow temperature : 260°C
Gradient of temperature rise : av 1-4℃/sec
Preheat : 160-190℃/within 90-120secs
220℃ up /within 30-60secs
Composition of solder Sn-3Ag-0.5Cu
2
Dip Temperature
Solder bathtub temperature : 260℃ max
within 5secs.
Preheating temperature : 100~130℃
deposit solder temperature.
Composition of solder Sn-3Ag-0.5Cu
3
Soldering iron tip temperature : 350°C max / within 3 seconds.
3
Wire Wound Chip Inductors
SWI1008HQ Series
Part No.
Inductance
(nH)
Tolerance
Q2
Min
S.R.F.3
Min
(MHz)
RDC 4
Max
(Ω)
IDC 5
Max
(mA)
Marking
1
SWI1008HQ 3N0 □-□□
3.0 @ 50MHz
K, J
70 @ 1500MHz
8100
0.04
1600
3N0
SWI1008HQ 7N8 □-□□
7.8 @ 50MHz
K, J
75 @ 1500MHz
3800
0.05
1600
7N8
SWI1008HQ 10N □-□□
10 @ 50MHz
K, J
60 @ 500MHz
3600
0.08
1300
10N
SWI1008HQ 12N □-□□
12 @ 50MHz
K, J, G
70 @ 500MHz
2800
0.06
1500
12N
SWI1008HQ 18N □-□□
18 @ 50MHz
K, J, G
62 @ 350MHz
2700
0.08
1400
18N
SWI1008HQ 22N □-□□
22 @ 50MHz
K, J, G
62 @ 350MHz
2050
0.07
1400
22N
SWI1008HQ 33N □-□□
33 @ 50MHz
K, J, G
75 @ 350MHz
1700
0.09
1300
33N
SWI1008HQ 39N □-□□
39 @ 50MHz
K, J, G
75 @ 350MHz
1300
0.09
1300
39N
SWI1008HQ 47N □-□□
47 @ 50MHz
K, J, G
75 @ 350MHz
1450
0.12
1200
47N
SWI1008HQ 56N □-□□
56 @ 50MHz
K, J, G
75 @ 350MHz
1230
0.12
1200
56N
SWI1008HQ 68N □-□□
68 @ 50MHz
K, J, G
80 @ 350MHz
1150
0.13
1000
68N
SWI1008HQ 82N □-□□
82 @ 50MHz
K, J, G
80 @ 350MHz
1060
0.16
1000
82N
SWI1008HQ R10 □-□□
100 @ 50MHz
K, J, G
62 @ 350MHz
820
0.16
1000
R10
1. Inductance is measured in HP-4287A RF LCR meter
with HP-16193 fixture.
2. Q is measured in HP-4287A RF LCR meter with
HP-16193 fixture.
3. SRF is measured in ENA E5071B network analyzer
or equivalent.
4. RDC is measured in HP-4338B milliohmeter or
equivalent.
5. For 15 °C Rise.
Remarks :
Unit weight = 0.025g (for ref.)
4
Wire Wound Chip Inductors
SWI1008HQ Series
L vs Freq Plot
10000
1000
R10
47N
22N
L (nH) 100
10N
10
3N0
1
1
10
100
1000
10000
Freq (MHz)
Q vs Freq Plot
140
22N
120
47N
3N3
100
80
Q
10N
60
R10
40
20
0
1
10
100
Freq (MHz)
5
1000
10000
Wire Wound Chip Inductors
SWI1008HQ Series
ITEM
Inductance and
Tolerance
Quality Factor
Electrical
Characteristics
Mechanical
Characteristics
Insulation
Resistance
Dielectric
Withstanding
Voltage
Temperature
Coefficient of
Inductance (TCL)
Component
Adhesion
(Push Test)
Drop Test
Thermal Shock
Test
Solderability
Resistance to
Soldering Heat
Vibration
(Random)
Cold Temperature
Storage
Endurance
Characteristics
High Temperature
Storage
Moisture
Resistance
High Temperature
with Loaded
CONDITION
Measuring Frequency :
As shown in Product Table
Measuring Temperature :
+25°C
Measured at 100V DC between
inductor terminals and center of case.
Measured at 500V AC between
inductor terminals and center of case
for a maximum of 1 minute.
Over -40°C to +85°C at
frequency specified in Product Table.
The component shall be reflow soldered onto a
P.C. Board ( 240°C ± 5°C for 20 seconds ).
Then a dynometer force gauge shall be applied
to any side of the component.
The inductor shall be dropped two times on the
concrete floor or the vinyl tile from 1M naturally.
Each cycle shall consist of 30 minutes at -40°C
followed by 30 minutes at +85°C with a 5 minutes
transition time between temperature extremes.
Test duration is 10 cycles.
Dip pads in flux and dip in solder pot containing
lead free solder at 240°C ± 5°C for 5 seconds.
Dip the components into flux and dip
into solder pot containing lead free solder
at 260°C ± 5°C for 5 ± 2 seconds.
Inductors shall be randomly vibrated at amplitude
of 1.5mm and frequency of 10-55Hz : 0.04G/Hz
for a minimum of 15 minutes per axis for each of
the three axes.
Inductors shall be stored at temperature
of -40°C ± 2°C for 1000hrs (+48 -0 hrs.)
Then inductors shall be subjected to standard
atmospheric conditions for 1 hour.
After that, measurement shall be made.
Inductors shall be stored at temperature
of 85°C ± 2°C for 1000hrs (+48 -0 hrs.)
Then inductors shall be subjected to standard
atmospheric conditions for 1 hour.
After that, measurement shall be made.
Inductors shall be stored in the chamber at 45°C
at 90-95 R.H. for 1000 hours. Then inductors are
to be tested after 2 hours at room temperature.
Inductors shall be stored in the chamber at +85°C
for 1000 hours with rated current applied.
Inductors shall be tested at the beginning of test at
500 hours and 1000 hours. Then inductors are to
be tested after 1 hour at room temperature.
6
SPECIFICATION
Within Specified Tolerance
1000 mega ohms minimum
No damage occurs when
the test voltage is applied.
+25 to 500 ppm/°C
6
TCL = L1 - L2 x 10 (ppm /°C)
L1(T1-T2)
Minimum 1Kg
Change In Inductance:
No more than 5%
Change In Q:
No more than 10%
Change In Appearance:
Without distinct damage
A minimum of 80% of the metalized
area must be covered with solder.
Change In Inductance:
No more than 5%
Change In Q:
No more than 10%
Change In Appearance:
Without distinct damage
Inductors shall not have a
shorted or open winding.
Wire Wound Chip Inductors
SWI1008HQ Series
Type
Pcs/Reel
SWI1008HQ
2,000
Φ 1.50
Type
SWI1008HQ
Chip
Cavity
Insert
Pitch
T
2.0
1.75
Tape Thickness
3.50
A
B
F
K
T
W
2.20
2.83
4.00
1.75
0.22
8.00
W
B
A
F
Blank
Portions
Chip Cavity
K
4.0
Leader
Top Tape Strength
The top tape requires a peel-off force of 0.2 to 0.7N
in the direction of the arrow as illustrated below.
Top Tape
0~15°
80mm min.
Direction of tape feed
160mm min.
Base Tape
Recommended Pattern
Dimensions (unit : m/m)
Type
A
B
C
A
SWI1008HQ
3.00
1.20
2.20
B
C
7