Datasheet

MPF Series
te
• SIP SSR
• Ratings to 4A @ 280 VAC
• SCR output for heavy industrial loads
• DC control
• Zero-crossing (resistive loads) or random-fire (inductive loads) output
PRODUCT SELECTION
4-10 VDC
Zero Crossing
Random Fire
MPF240D4
MPF240D4R
MPF240D4
MPF240D4R
12-280
600
0.1
500
4
0.1
40
1.5
0.5
12-280
600
0.1
500
4
0.1
40
1.5
0.5
MPF240D4
MPF240D4R
4-10 VDC
4.0 VDC
1.0 VDC
15 mAdc
300 Ohm
1/2 Cycle
1/2 Cycle
4-10 VDC
4.0 VDC
1.0 VDC
15 mAdc
300 Ohm
0.1
1/2 Cycle
ol
e
Control Voltage
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3)
Maximum Load Current [Arms]
Minimum Load Current [Arms]
Maximum Surge Current (16.6ms) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Minimum Power Factor (with Maximum Load)
bs
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Must Turn On Voltage
Must Turn Off Voltage
Typical Input Current @ 5 VDC
Nominal Input Impedance
Maximum Turn-On Time [msec]
Maximum Turn-Off Time msec]
O
GENERAL SPECIFICATIONS
Description
Dielectric Strength, Input/Output/Base (50/60Hz)(2)
Minimum Insulation Resistance (@ 500 VDC)(2)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Encapsulation
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) Dielectric and ins ulation resistance are measured are between input and output
3) Off-State dv/dt test method per EIA/NARM standard RS-443
Parameters
3750 Vrms
10 9 Ohm
8.0 pF
-30 to 80°C
-30 to 125°C
0.6 oz. (17g)
Thermally Conductive Epoxy
ol
e
te
MECHANICAL SPECIFICATIONS
bs
THERMAL DERATE INFORMATION
AGENCY APPROVALS
O
UL E116950
CSA LR81689
Rev. 120110
O
te
ol
e
bs
O
bs
ol
e
te
ANNEX - ENVIROMENTAL INFORMATION