Generation 3 H16WD Series • Ratings from 25A to 90A @ 48-660 V AC • 1600 Volt Blocking • SCR output for heavy industrial loads • DC control • Zero-crossing (resistive loads) or random-fire (inductive loads) output • Optional LED Status Indicator For 4th Generation datasheet click here PRODUCT SELECTION Control Voltage 4-32 Vdc 25A 50A 75A 90A H16WD6025 H16WD6050 H16WD6075 H16WD6090 AVAILABLE OPTIONS OUTPUT SPECIFICATIONS (1) Description Operating Voltage (47-440Hz) [Vrms] Transient Overvoltage [Vpk] Rated Load Current (2) [Arms] Rated Load Current {UL508 Motor Controller} (2) [Arms] Minimum Load Current [mArms] Maximum Off-State Leakage Current @ Rated Voltage [mArms] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3) Maximum 1 Cycle Surge Current (50/60Hz) [Apk] Maximum I²t for Fusing (50/60Hz) [A² sec] Thermal Resistance Junction to Case (Rjc) [°C/W] Maximum On-State Voltage Drop @ Rated Current [Vpk] HP rating UL 508/IEC60947[HP (KW)]: 240 VAC HP rating UL 508/IEC60947[HP (KW)]: 380 VAC HP rating UL 508/IEC60947[HP (KW)]: 480 VAC HP rating UL 508/IEC60947[HP (KW)]: 600 VAC Wire Size max (solid/stranded) [AWG/ IEC mm²] Output Terminal Screw Torque Range [in lb (Nm) 25A 50A 75A 90A 48-660 1600 25 10 150 1.0 500 239/250 285/259 1.02 1.6 1.5 (1.1) 2 (1.5) 3 (2.2) 3 (2.2) 2 x 8/8.4 18-20 (2-2.2) 48-660 1600 50 20 150 1.0 500 597/625 1779/1621 0.63 1.6 3 (2.2) 5 (3.7) 5 (3.7) 10 (7.4) 2 x 8/8.4 18-20 (2-2.2) 48-660 1600 75 30 150 1.0 500 954/1000 4555/4150 0.31 1.6 5 (3.7) 7.5 (5.6) 10 (7.4) 15 (11.2) 2 x 8/8.4 18-20 (2-2.2) 48-660 1600 90 45 150 1.0 500 1145/1200 6560/5976 0.28 1.6 7.5 (5.6) 15 (11.2) 20 (14.9) 25 (18.6) 2 x 8/8.4 18-20 (2-2.2) Generation 3 INPUT SPECIFICATIONS (1) Description Control Voltage Range Must Turn-Off Voltage Maximum Reverse Voltage Minimum Input Current @ Minimum Voltage (for on-state) Maximum Input Current @ Maximum Voltage Nominal Input Impedance Maximum Turn-On Time [msec] (5) Maximum Turn-Off Time [msec] Wire Size max (solid/stranded) [AWG/ IEC mm²] LED Status Indicator (Color) Input Terminal Screw Torque Range: DC Control 4-32 VDC 1 .0 VDC 32 VDC 9mA 11mA See Note 4 1/2 Cycle 1/2 Cycle 2 x 12 / 3.3 w/G Option (green) 8-10 in lb (0.9-1.1Nm) GENERAL SPECIFICATIONS Description Dielectric Strength, Input/Output/Base (50/60Hz) Minimum Insulation Resistance (@ 500 V DC) Maximum Capacitance, Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) Housing Material SSR Mounting Torque Range [in lbs/Nm] Baseplate Material RoHS Exemption #’s GENERAL NOTES GENERAL NOTES 1) All parameters at 40°C and per section unless otherwise specified. 2) Heat sinking required, see derating curves. 3) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 4) Input circuitry version incorporates active current limiter. 5) Turn-on time for DC control random turn-on versions is 0.02 msec WIRING DIAGRAM Parameters 4000 Vrms 1010 Ohm 8 pF -40 to 80 °C -40 to 125 °C 3 oz (86.5 g) Thermoplastic Polyester 18-20 (2-2.2) Aluminum 5(a), 7(a), 7(c)-I Generation 3 MECHANICAL SPECIFICATIONS THERMAL DERATE INFORMATION AGENCY APPROVALS Designed in accordance with the requirements of IEC 62314 IEC 61000-4-2 : Electrostatic Discharge – Level 3 IEC 61000-4-4 : Electrically Fast Transients – Level 3 Criteria B IEC 61000-4-5 : Electrical Surges – Level 3 Criteria B Rev. 120811 Generation 3 ANNEX - ENVIROMENTAL INFORMATION Generation 3