3rd Generation DataSheet

Generation 3
H16WD Series
• Ratings from 25A to 90A @ 48-660 V AC
• 1600 Volt Blocking
• SCR output for heavy industrial loads
• DC control
• Zero-crossing (resistive loads) or random-fire (inductive loads) output
• Optional LED Status Indicator
For 4th Generation datasheet click here
PRODUCT SELECTION
Control Voltage
4-32 Vdc
25A
50A
75A
90A
H16WD6025
H16WD6050
H16WD6075
H16WD6090
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage (47-440Hz) [Vrms]
Transient Overvoltage [Vpk]
Rated Load Current (2) [Arms]
Rated Load Current {UL508 Motor Controller} (2) [Arms]
Minimum Load Current [mArms]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3)
Maximum 1 Cycle Surge Current (50/60Hz) [Apk]
Maximum I²t for Fusing (50/60Hz) [A² sec]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
HP rating UL 508/IEC60947[HP (KW)]: 240 VAC
HP rating UL 508/IEC60947[HP (KW)]: 380 VAC
HP rating UL 508/IEC60947[HP (KW)]: 480 VAC
HP rating UL 508/IEC60947[HP (KW)]: 600 VAC
Wire Size max (solid/stranded) [AWG/ IEC mm²]
Output Terminal Screw Torque Range [in lb (Nm)
25A
50A
75A
90A
48-660
1600
25
10
150
1.0
500
239/250
285/259
1.02
1.6
1.5 (1.1)
2 (1.5)
3 (2.2)
3 (2.2)
2 x 8/8.4
18-20 (2-2.2)
48-660
1600
50
20
150
1.0
500
597/625
1779/1621
0.63
1.6
3 (2.2)
5 (3.7)
5 (3.7)
10 (7.4)
2 x 8/8.4
18-20 (2-2.2)
48-660
1600
75
30
150
1.0
500
954/1000
4555/4150
0.31
1.6
5 (3.7)
7.5 (5.6)
10 (7.4)
15 (11.2)
2 x 8/8.4
18-20 (2-2.2)
48-660
1600
90
45
150
1.0
500
1145/1200
6560/5976
0.28
1.6
7.5 (5.6)
15 (11.2)
20 (14.9)
25 (18.6)
2 x 8/8.4
18-20 (2-2.2)
Generation 3
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Must Turn-Off Voltage
Maximum Reverse Voltage
Minimum Input Current @ Minimum Voltage (for on-state)
Maximum Input Current @ Maximum Voltage
Nominal Input Impedance
Maximum Turn-On Time [msec] (5)
Maximum Turn-Off Time [msec]
Wire Size max (solid/stranded) [AWG/ IEC mm²]
LED Status Indicator (Color)
Input Terminal Screw Torque Range:
DC Control
4-32 VDC
1 .0 VDC
32 VDC
9mA
11mA
See Note 4
1/2 Cycle
1/2 Cycle
2 x 12 / 3.3
w/G Option (green)
8-10 in lb (0.9-1.1Nm)
GENERAL SPECIFICATIONS
Description
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 V DC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Housing Material
SSR Mounting Torque Range [in lbs/Nm]
Baseplate Material
RoHS Exemption #’s
GENERAL NOTES
GENERAL NOTES
1) All parameters at 40°C and per section unless otherwise specified.
2) Heat sinking required, see derating curves.
3) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
4) Input circuitry version incorporates active current limiter.
5) Turn-on time for DC control random turn-on versions is 0.02 msec
WIRING DIAGRAM
Parameters
4000 Vrms
1010 Ohm
8 pF
-40 to 80 °C
-40 to 125 °C
3 oz (86.5 g)
Thermoplastic Polyester
18-20 (2-2.2)
Aluminum
5(a), 7(a), 7(c)-I
Generation 3
MECHANICAL SPECIFICATIONS
THERMAL DERATE INFORMATION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
IEC 61000-4-2 : Electrostatic Discharge – Level 3
IEC 61000-4-4 : Electrically Fast Transients – Level 3 Criteria B
IEC 61000-4-5 : Electrical Surges – Level 3 Criteria B
Rev. 120811
Generation 3
ANNEX - ENVIROMENTAL INFORMATION