QFN5x5EMC

Test Report
REPORT NO.
CTS REF.
DATE REPORTED
PAGE
:
:
:
:
CTSSA/01998-1/14
CTSSA/14/0336/Hitachi
th
24 Feb, 2014
1 of 5
Hitachi Chemical (M) Sdn. Bhd.
Plot 501, Prai Industrial Estate, 13600 Prai, Penang
The following merchandise was (were) submitted and identified by the client as:
Sample Description
Sample Name
Sample Receiving Date
Testing Period
Date Completed
Reporting Date
:
:
:
:
:
:
Epoxy Molding Compound
CEL-9220HF 13 Series
03/02/2014
03/02/2014 to 07/02/2014
07/02/2014
24/02/2014
Test Result
:
Please see the next page
Analysts
:
Ng Jing Wei, Cho Kar Yen, Tan Li Wei & Isabelle Chan Suet Yee
SGS LABORATORY SERVICES (M) SDN. BHD.
f
-------------------------CHONG KIEN LEN
B.Sc.(HONS) AMIC
SENIOR LAB MANAGER
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx . Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only
and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for three months only.
SGS Laboratory Services (M) Sdn. Bhd.
(Company No. 63972-M)
No.26 Jalan Anggerik Vanilla 31/93 Kota Kemuning 40460 Shah Alam, Selangor Darul Ehsan, Malaysia
t +6(03) 5121 2320 f +6 (03) 5121 9082 www.sgs.com
Member of the SGS Group (SGS SA)
Test Report
REPORT NO.
CTS REF.
DATE REPORTED
PAGE
Company
:
:
:
:
:
CTSSA/01998-1/14
CTSSA/14/0336/Hitachi
th
24 Feb, 2014
2 of 5
Hitachi Chemical (M) Sdn. Bhd.
Plot 501, Prai Industrial Estate, 13600 Prai, Penang
Test Result
Sample Description
Sample Name
:
:
Epoxy Molding Compound
CEL-9220HF 13 Series
RoHS Directive 2011/65/EU Annex II
Test Item (s) :
Unit
Method
Chromium VI (Cr6+)
ppm
IEC 62321 : 2008 Annex C
Cadmium (Cd)
ppm
Mercury (Hg)
Lead (Pb)
NOTE:
Analysts:
Instrument
UV Vis Spectrophotometer
MDL
Results
Limit
2
N.D.
1000
IEC 62321 : 2008
ICP OES
2
N.D.
100
ppm
IEC 62321 : 2008
ICP OES
2
N.D.
1000
ppm
IEC 62321 : 2008
ICP OES
2
N.D.
1000
(a) N.D. = Not detected (<MDL)
(b) ppm = mg/kg
(c) MDL= Method Detection Limit
(d) Testing based on original basis
Ng Jing Wei & Cho Kar Yen
SGS LABORATORY SERVICES (M) SDN. BHD.
f
-------------------------CHONG KIEN LEN
B.Sc.(HONS) AMIC
SENIOR LAB MANAGER
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx . Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only
and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for three months only.
SGS Laboratory Services (M) Sdn. Bhd.
(Company No. 63972-M)
No.26 Jalan Anggerik Vanilla 31/93 Kota Kemuning 40460 Shah Alam, Selangor Darul Ehsan, Malaysia
t +6(03) 5121 2320 f +6 (03) 5121 9082 www.sgs.com
Member of the SGS Group (SGS SA)
Test Report
REPORT NO.
CTS REF.
DATE REPORTED
PAGE
Company
:
:
:
:
:
CTSSA/01998-1/14
CTSSA/14/0336/Hitachi
th
24 Feb, 2014
3 of 5
Hitachi Chemical (M) Sdn. Bhd.
Plot 501, Prai Industrial Estate, 13600 Prai, Penang
Test Result
Sample Description
Sample Name
:
:
Epoxy Molding Compound
CEL-9220HF 13 Series
RoHS Directive 2011/65/EU Annex II
Test Item (s) :
Unit
Method
Instrument
MDL
Result
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
GCMS as per IEC 62321 : 2008
GCMS as per IEC 62321 : 2008
GCMS as per IEC 62321 : 2008
GCMS as per IEC 62321 : 2008
GCMS as per IEC 62321 : 2008
GCMS as per IEC 62321 : 2008
GCMS as per IEC 62321 : 2008
GCMS as per IEC 62321 : 2008
GCMS as per IEC 62321 : 2008
GCMS as per IEC 62321 : 2008
GCMS
GCMS
GCMS
GCMS
GCMS
GCMS
GCMS
GCMS
GCMS
GCMS
5
5
5
5
5
5
5
5
5
5
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
NOTE: (a) N.D. = Not detected (<MDL)
(b) ppm = mg/kg
(c) MDL= Method Detection Limit
GCMS as per IEC 62321 : 2008
GCMS as per IEC 62321 : 2008
GCMS as per IEC 62321 : 2008
GCMS as per IEC 62321 : 2008
GCMS as per IEC 62321 : 2008
GCMS as per IEC 62321 : 2008
GCMS as per IEC 62321 : 2008
GCMS as per IEC 62321 : 2008
GCMS as per IEC 62321 : 2008
GCMS as per IEC 62321 : 2008
GCMS
GCMS
GCMS
GCMS
GCMS
GCMS
GCMS
GCMS
GCMS
GCMS
5
5
5
5
5
5
5
5
5
5
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
Limit
PBBs (Polybrominated Biphenyls)
Monobromo Biphenyl
Dibromo Biphenyl
Tribromo Biphenyl
Tetrabromo Biphenyl
Pentabromo Biphenyl
Hexabromo Biphenyl
Heptabromo Biphenyl
Octabromo Biphenyl
Nonabromo Biphenyl
Decabromo Biphenyl
1000
PBDEs (Polybrominated Diphenyl ethers)
Monobromo Diphenyl Ether
Dibromo Diphenyl Ether
Tribromo Diphenyl Ether
Tetrabromo Diphenyl Ether
Pentabromo Diphenyl Ether
Hexabromo Diphenyl Ether
Heptabromo Diphenyl Ether
Octabromo Diphenyl Ether
Nonabromo Diphenyl Ether
Decabromo Diphenyl Ether
1000
Analysts: Tan Li Wei & Isabelle Chan Suet Yee
SGS LABORATORY SERVICES (M) SDN. BHD.
f
-------------------------CHONG KIEN LEN
B.Sc.(HONS) AMIC
SENIOR LAB MANAGER
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx . Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only
and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for three months only.
SGS Laboratory Services (M) Sdn. Bhd.
(Company No. 63972-M)
No.26 Jalan Anggerik Vanilla 31/93 Kota Kemuning 40460 Shah Alam, Selangor Darul Ehsan, Malaysia
t +6(03) 5121 2320 f +6 (03) 5121 9082 www.sgs.com
Member of the SGS Group (SGS SA)
Test Report
REPORT NO.
CTS REF.
DATE REPORTED
PAGE
Company
:
:
:
:
:
CTSSA/01998-1/14
CTSSA/14/0336/Hitachi
th
24 Feb, 2014
4 of 5
Hitachi Chemical (M) Sdn. Bhd.
Plot 501, Prai Industrial Estate, 13600 Prai, Penang
Test Result
Sample Description
Sample Name
:
:
Epoxy Molding Compound
CEL-9220HF 13 Series
HITACHI CHEMICAL (M) SDN. BHD.
CTSSA/01998-1/14
SGS LABORATORY SERVICES (M) SDN. BHD.
f
-------------------------CHONG KIEN LEN
B.Sc.(HONS) AMIC
SENIOR LAB MANAGER
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx . Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only
and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for three months only.
SGS Laboratory Services (M) Sdn. Bhd.
(Company No. 63972-M)
No.26 Jalan Anggerik Vanilla 31/93 Kota Kemuning 40460 Shah Alam, Selangor Darul Ehsan, Malaysia
t +6(03) 5121 2320 f +6 (03) 5121 9082 www.sgs.com
Member of the SGS Group (SGS SA)
Test Report
REPORT NO.
CTS REF.
DATE REPORTED
PAGE
:
:
:
:
CTSSA/01998-1/14
CTSSA/14/0336/Hitachi
th
24 Feb, 2014
5 of 5
1. DETERMINATION OF CADMIUM CONTENT BY
IEC 62321 2008
2. DETERMINATION OF LEAD CONTENT BY
IEC 62321 2008
Sample Receiving and Registration
Sample Receiving and Registration
Sample Preparation
Sample Preparation
Weight sample (0.2-0.5g) into digestion vessel
Weight sample (0.2-0.5g) into digestion vessel
Acid digestion (Microwave)
Acid digestion (Microwave)
“Totally Dissolved”
“Totally Dissolved”
Filtration
Filtration
Analyses by ICP
Analyses by ICP
3. DETERMINATION OF MERCURY CONTENT BY
IEC 62321 2008
4. DETERMINATION OF HEXAVALENT CHROMIUM
BY IEC 62321 2008
Sample Receiving and Registration
Sample Preparation
Sample Preparation
Add colour-developing reagent
Weight sample (0.2-0.5g) into digestion vessel
Acidify with H2SO4
Acid digestion (Microwave)
Let stand for 5-10 min
“Totally Dissolved”
Analyses by UV- Spectrophotometer (540 nm)
Filtration
Analyses by ICP
5. DETERMINATION OF PBB/PBDE WITH GC-MS
BY IEC 62321 2008
Sample Preparation
Weight sample (0.5-4.0g) into extraction thimble
Soxhlet Extraction with Toluene
Filter through 0.45 um membrane filter
Analyses by GC-MS (with appropriate dilution)
SGS LABORATORY SERVICES (M) SDN. BHD.
f
-------------------------CHONG KIEN LEN
B.Sc.(HONS) AMIC
SENIOR LAB MANAGER
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx . Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only
and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for three months only.
SGS Laboratory Services (M) Sdn. Bhd.
(Company No. 63972-M)
No.26 Jalan Anggerik Vanilla 31/93 Kota Kemuning 40460 Shah Alam, Selangor Darul Ehsan, Malaysia
t +6(03) 5121 2320 f +6 (03) 5121 9082 www.sgs.com
Member of the SGS Group (SGS SA)