BCP060T2 HIGH EFFICIENCY pHEMT POWER FET CHIP (.25µm x 600µm) The BeRex BCP060T2 is a GaAs Power pHEMT with a nominal 0.25 micron gate length and 600 micron gate width making it ideally suited for applications requiring high-gain and medium power in the 1000 MHz to 26.5 GHz frequency range. The product may be used in either wideband (6-18 GHz) or narrow-band applications. The BCP060T2 is produced using state of the art metallization with SI3N4 passivation and is screened to assure reliability. PRODUCT FEATURES • • • • 29 dBm Typical Output Power 12 dB Typical Power Gain @ 12 GHz 0.25 X 600 Micron Recessed Gate 2 Gate Pads / 2 Drain Pads APPLICATIONS • • • Commercial Military / Hi-Rel. Test & Measurement DC CHARACTERISTICS Ta = 25° C SYMBOL Idss Gm Vp BVgd BVgs Rth PARAMETER/TEST CONDITIONS Saturated Drain Current (Vgs = 0V, Vds = 2V) Transconductance (Vds = 3V, Vgs = 50% Idss) Pinch-off Voltage (Ids = 0.6 mA, Vds = 2V) Drain Breakdown Voltage (Ig = 0.6 mA, source open) Source Breakdown Voltage (Ig = 0.6 mA, drain open) MIN. TYPICAL MAX. UNIT 120 180 240 -1.1 -16 -14 240 mA mS V V V - 2.5 Thermal Resistance (Au-Sn Eutectic Attach) - 0.5 -12 65 °C/W ELECTRICAL CHARACTERISTIC (TUNED FOR POWER) Ta = 25° C SYMBOL PARAMETER/TEST CONDITIONS P1dB Output Power @ P1dB (Vds = 8V, Ids = 50% Idss) G1dB Gain @ P1dB (Vds = 8V, Ids = 50% Idss) PAE PAE @ P1dB (Vds = 8V, Ids = 50% Idss) www.berex.com TEST FREQ. 12 GHz 18 GHz 12 GHz 18 GHz 12 GHz 18 GHz MIN. TYPICAL 27.5 27.5 11.0 8.0 29.0 29.0 12.0 9.0 65 60 BeRex, Inc. 3350 Scot Blvd. #61-01 Santa Clara, CA 95054 tel. (408) 452-5595 Specifications are subject to change without notice. ©BeRex 2015 Rev. 1.7 MAX. UNIT dBm dB % January 2015 BCP060T ELECTRICAL CHARACTERISTIC (TUNED FOR GAIN) Ta = 25° C SYMBOL PARAMETER/TEST CONDITIONS P1dB Output Power @ P1dB (Vds = 8V, Ids = 50% Idss) G1dB Gain @ P1dB (Vds = 8V, Ids = 50% Idss) PAE PAE @ P1dB (Vds = 8V, Ids = 50% Idss) TEST FREQ. 12 GHz 18 GHz 12 GHz 18 GHz 12 GHz 18 GHz MIN. TYPICAL 25.5 26.0 12.5 9.5 27.0 28.0 13.5 10.5 60 60 MAX. UNIT dBm dB % MAXIMUM RATING (Ta = 25° C) SYMBOLS Vds Vgs Ids Igsf Pin Tch Tstg Pt PARAMETERS Drain-Source Voltage Gate-Source Voltage Drain Current Forward Gate Current Input Power Channel Temperature Storage Temperature Total Power Dissipation ABSOLUTE 12 V -8 V Idss 30 mA 24 dBm 175° C -60° C - 150° C 2.1 W CONTINUOUS 8V -3 V Idss 5 mA @3dB Compression 150° C -60° C - 150° C 1.7 W Exceeding any of the above Maximum Ratings will result in reduced MTTF and may cause permanent damage to the device. PIN_POUT/Gain, PAE (12 GHz) Frequency = 12GHz Frequency = 12GHz Vds= 8 V, Ids = 50% Idss (Tuned for Power) Vds = 8 V, Ids = 50% Idss (Tuned for Gain) www.berex.com BeRex, Inc. 3350 Scot Blvd. #61-01 Santa Clara, CA 95054 tel. (408) 452-5595 Specifications are subject to change without notice. ©BeRex 2015 Rev. 1.7 January 2015 BCP060T2 PIN_POUT/Gain, PAE (18 GHz) Frequency = 18GHz Frequency = 18GHz Vds = 8 V, Ids = 50% Idss (Tuned for Power) Vds = 8 V, Ids = 50% Idss (Tuned for Gain) S-PARAMETER (Vds = 8V, Ids = 50% Idss) FREQ. [GHZ] S11 [MAG] S11 [ANG.] S21 [MAG] S21 [ANG.] S12 [MAG] S12 [ANG.] S22 [MAG] S22 [ANG.] 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 0.92 0.87 0.84 0.83 0.82 0.82 0.82 0.83 0.83 0.84 0.85 0.86 0.87 0.89 0.90 0.91 0.92 0.92 0.93 0.93 0.93 0.92 0.93 0.92 0.92 -64.25 -105.65 -131.06 -149.30 -162.29 -172.56 177.98 170.03 162.91 155.83 150.15 146.03 141.12 137.47 134.65 131.13 127.82 125.14 120.98 119.34 117.00 114.60 113.16 111.43 109.91 13.19 9.68 7.33 5.79 4.75 4.00 3.44 2.99 2.64 2.33 2.08 1.86 1.67 1.52 1.39 1.28 1.19 1.10 1.02 0.95 0.88 0.81 0.76 0.70 0.64 141.20 117.34 101.49 89.56 79.77 71.40 63.68 56.43 49.71 43.12 37.02 31.78 26.35 21.34 17.24 12.51 7.56 2.79 -2.09 -6.78 -10.66 -14.89 -18.59 -22.44 -25.94 0.033 0.048 0.053 0.055 0.055 0.055 0.054 0.053 0.051 0.049 0.048 0.046 0.045 0.045 0.045 0.046 0.047 0.047 0.049 0.051 0.051 0.054 0.055 0.056 0.055 56.560 37.422 27.876 21.285 17.345 14.429 12.980 11.367 10.094 8.831 9.020 9.038 9.686 9.837 11.047 11.134 10.856 9.956 9.789 7.389 8.789 8.633 9.580 9.195 11.221 0.46 0.37 0.32 0.29 0.28 0.28 0.29 0.29 0.30 0.31 0.33 0.34 0.35 0.37 0.38 0.40 0.42 0.44 0.45 0.47 0.48 0.49 0.52 0.52 0.54 -36.52 -58.58 -72.07 -80.80 -88.81 -93.34 -97.85 -103.15 -106.98 -111.51 -116.26 -119.38 -123.53 -128.98 -131.05 -134.67 -138.64 -141.24 -143.25 -147.74 -150.89 -154.89 -158.03 -161.04 -165.44 26 0.93 109.66 0.59 -28.89 0.056 15.488 0.55 -168.02 Note: S-parameters include bond wires. Reference planes are at edge of substrates shown on “Wire Bonding Information” figure below. www.berex.com BeRex, Inc. 3350 Scot Blvd. #61-01 Santa Clara, CA 95054 tel. (408) 452-5595 Specifications are subject to change without notice. ©BeRex 2015 Rev. 1.7 January 2015 BCP060T2 Wire Bonding Information Follow the wire bonding diagrams recommended by BeRex below to achieve optimum device performance. BeRex recommends thermo-compression wedge bonding. As a general rule, bonding temperature should be kept to a maximum of 280°C for no longer than 2 minutes for all bonding wires. Ultrasonic bonding is not recommended. Bonding Wire information 1. Gate to input transmission line - Length and Height : 400 um and 250 um - Number of wire : 2 wire 2. Drain to output transmission line - Length and Height : 350 um and 250 um - Number of wire : 2 wire 3. Source to ground plate - Length and Height : 200 um and 250 um - Number of wire : 6 wires ※ The diameter of bonding wires : 1 mil DIE ATTACH RECOMMENDATIONS: BeRex recommends the “Eutectic” die attach using Au-Sn (80%-20%) pre-forms. The die attach station must have accurate temperature control, and the operation should be performed with parts no hotter than 300°C for less than 10 seconds. An inert forming gas (90% N2-10% H2) or clean, dry N2 should be used. HANDLING PRECAUTIONS: GaAs FETs are very sensitive to and may be damaged by Electrostatic Discharge (ESD). Therefore, proper ESD precautions must be taken whenever you are handling these devices. It is critically important that all work surfaces, and assembly equipment, as well as the operator be properly grounded when handling these devices to prevent ESD damage. STORAGE & SHIPPING: BeRex’s standard chip device shipping package consists of an antistatic “Gel-Pak”, holding the chips, placed inside a sealed antistatic and moisture barrier bag. This packaging is designed to provide a reasonable measure of protection from both mechanical and ESD damage. Chip devices should be stored in a clean, dry Nitrogen gas environment at room temperature until they are required for assembly. Only open the shipping package or perform die assembly in a work area with a class 10,000 or better clean room environment to prevent contamination of the exposed devices. www.berex.com BeRex, Inc. 3350 Scot Blvd. #61-01 Santa Clara, CA 95054 tel. (408) 452-5595 Specifications are subject to change without notice. ©BeRex 2015 Rev. 1.7 January 2015 BCP060T2 CAUTION: THIS PRODUCT CONTAINS GALLIUM ARSENIDE (GaAs) WHICH CAN BE HAZARDOUS TO THE HUMAN BODY AND THE ENVIRONMENT. THEREFORE, IT MUST BE HANDLED WITH CARE AND IN ACCORDANCE WITH ALL GOVERNMENTAL AND COMPANY REGULATIONS FOR THE SAFE HANDLING AND DISPOSAL OF HAZARDOUS WASTE. DO NOT BURN, DESTROY, CUT, CRUSH OR CHEMICALLY DISSOLVE THE PRODUCT. DO NOT LICK THE PRODUCT OR IN ANY WAY ALLOW IT TO ENTER THE MOUTH. EXCLUDE THE PRODUCT FROM GENERAL INDUSTRIAL WASTE OR GARBAGE AND DISPOSE OF ONLY IN ACCORDANCE TO APPLICABLE LAWS AND/OR ORDINANCES DISCLAIMER BEREX RESERVES THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE TO ANY PRODUCTS HEREIN TO IMPROVE RELIABILITY, FUNCTION OR DESIGN. BEREX DOES NOT ASSUME ANY LIABILITY ARISING OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT DESCRIBED HEREIN. LIFE SUPPORT POLICY BEREX PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES WITHOUT THE EXPRESS WRITTEN APPROVAL OF BEREX. 1. Life support devices or systems are devices or systems which (a) are intended for surgical implant into the body, or (b) support or sustain life, or (c) whose failure to perform when properly used in accordance with instructions for use provided in labeling, can be reasonably expected to result in significant injury to the user. 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. RoHS COMPLIANT For complete specifications, S-parameters and information on bonding and handling, visited our website; www.berex.com www.berex.com BeRex, Inc. 3350 Scot Blvd. #61-01 Santa Clara, CA 95054 tel. (408) 452-5595 Specifications are subject to change without notice. ©BeRex 2015 Rev. 1.7 January 2015