AN 644: Migration Between Stratix V GX and Stratix V GT

Migration Between Stratix V GX and
Stratix V GT Devices
AN-644-1.0
Application Note
This application note provides guidelines for designing cross-family migration (also
known as vertical migration) between Altera® Stratix® V GX and Stratix V GT devices.
With advance planning that takes into account the different power supply voltages
and available packages in both families, you can design a PCB that can be assembled
with either a Stratix V GX or a Stratix V GT device in the same package.
Follow these guidelines to use either device in your PCB design. Altera recommends
using these guidelines throughout your PCB design process to ensure a seamless
migration of designs between Stratix V GX and GT devices. Cross-family migration
between Stratix V GX and GT FPGAs allows you to design with Stratix V GT FPGAs
and test the system with Stratix V GX FPGAs.
Supported Migration Device Packages
Table 1 lists the devices that can migrate between the Stratix V GX and GT device
packages. The four devices listed in Table 1 allow cross-family migration. The major
difference between Stratix V GX and Stratix V GT devices is the transceivers. 5SGXA5
and 5SGXA7 devices offer 48 integrated 14.1-Gbps GX transceivers. 5SGTC5 and
5SGTC7 devices replace four GX transceivers in the Stratix V GX device with 28-Gbps
GT transceivers. To support ultra-high bandwidth, Stratix V GT devices also replace
the package pins of 12 transceivers in a Stratix V GX device with power pins.
1
You can use both Stratix V GT and GX devices in PCB designs based on a Stratix V GT
device pin-out. However, PCB designs based on a Stratix V GX device pin-out only
use GX devices.
Table 1. Cross-Family Migration for Stratix V GX and Stratix V GT Devices
F1517 40 x 40 (mm) 1.0-mm pitch
Device
Package (1)
User I/Os (2)
LVDS Count
28-Gbps Channels /
14.1-Gbps Channels
5SGXA5
NF40
600
150
0/48
5SGXA7
NF40
600
150
0/48
5SGTC5
KF40
600
150
4/32
5SGTC7
KF40
600
150
4/32
Notes to Table 1:
(1) For each package, N indicates 48 transceiver channels, K indicates 36 transceiver channels, F stands for FineLine
BGA package type, and 40 indicates the 1517 pins and the 40 × 40 mm package dimension.
(2) The user I/O count includes all general purpose I/Os, dedicated clock pins, and dual-purpose configuration pins.
Dedicated configuration pins are not included in the user I/O count.
101 Innovation Drive
San Jose, CA 95134
www.altera.com
May 2011
© 2011 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, HARDCOPY, MAX, MEGACORE, NIOS,
QUARTUS and STRATIX are Reg. U.S. Pat. & Tm. Off. and/or trademarks of Altera Corporation in the U.S. and other countries.
All other trademarks and service marks are the property of their respective holders as described at
www.altera.com/common/legal.html. Altera warrants performance of its semiconductor products to current specifications in
accordance with Altera’s standard warranty, but reserves the right to make changes to any products and services at any time
without notice. Altera assumes no responsibility or liability arising out of the application or use of any information, product, or
service described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest
version of device specifications before relying on any published information and before placing orders for products or services.
Altera Corporation
Subscribe
Page 2
Differences Between Stratix V GX and Stratix V GT Devices
Differences Between Stratix V GX and Stratix V GT Devices
A Stratix V GT device replaces four GX transceiver channels on the right side of a
Stratix V GX device with GT transceiver channels. Table 2 lists the migrated pin
locations. To use a GT transceiver channel, the PCB trace design of these pins must
meet 28-Gbps requirements.
Table 2. Migrated Pin Locations and Functions of Stratix V GX and GT Device Transceiver Pins
Pin Location
Stratix V GX Device Pin Name
GX Transceivers
Stratix V GT Device Pin Name
GT Transceivers
AM1
GXB_RX_R3n, GXB_REFCLK_R3n
GTB_RX_R0n
AM2
GXB_RX_R3p, GXB_REFCLK_R3p
GTB_RX_R0p
AB1
GXB_RX_R9n, GXB_REFCLK_R9n
GTB_RX_R1n
AB2
GXB_RX_R9p, GXB_REFCLK_R9p
GTB_RX_R1p
P1
GXB_RX_R15n, GXB_REFCLK_R15n
GTB_RX_R2n
P2
GXB_RX_R15p, GXB_REFCLK_R15p
GTB_RX_R2p
F1
GXB_RX_R21n, GXB_REFCLK_R21n
GTB_RX_R3n
F2
GXB_RX_R21p, GXB_REFCLK_R21p
GTB_RX_R3p
AP1
GXB_TX_R3n
GTB_TX_R0n
AP2
GXB_TX_R3p
GTB_TX_R0p
AD1
GXB_TX_R9n
GTB_TX_R1n
AD2
GXB_TX_R9p
GTB_TX_R1p
T1
GXB_TX_R15n
GTB_TX_R2n
T2
GXB_TX_R15p
GTB_TX_R2p
H1
GXB_TX_R21n
GTB_TX_R3n
H2
GXB_TX_R21p
GTB_TX_R3p
A Stratix V GT device also replaces the receiver pins of eight Stratix V GX transceivers
with GT transceiver power pins in order to provide a clean power supply to the GT
transceivers. Table 3 lists the migrated pin locations. During the PCB design, these
pins must be bonded to power planes.
1
If a Stratix V GX device is used in the GX and GT device-compatible PCB, connect the
pins in Table 3 to the dedicated 1.0 V GT power supplies; do not leave them floating.
Stratix V GT transceivers have their own power supplies: VCCR_GTBR,
VCCT_GTBR, VCCL_GTBR, and VCCA_GTBR. To design a PCB for both GX and GT
devices, you must consider the power supply requirements. You have many options
for designing the power supplies of the migration PCBs. The following power supply
design guidelines give an example of PCB design that includes all the data rate
options:
■
VCCR_GTBR, VCCL_GTBR, and VCCT_GTBR are 1.0 V power supplies. They
may share the same power regulator. However, they must be isolated from each
other by at least 60 dB.
■
Keep VCCR_GXB on its own regulator that is adjustable from 0.85 V to 1.0 V.
■
Keep VCCT_GXB on its own regulator that is adjustable from 0.85 V to 1.0 V.
Migration Between Stratix V GX and Stratix V GT Devices
May 2011 Altera Corporation
Differences Between Stratix V GX and Stratix V GT Devices
■
Page 3
Keep VCCA_GXBL on one power regulator and VCCA_GXBR and VCCA_GTBR
on a different power regulator. Use regulators that can be adjusted between 2.5 V
and 3.0 V.
f For updated power supply designs, refer to the Stratix V GT Device Family Pin
Connection Guidelines.
Table 3. Migrated Pin Locations and Functions of Stratix V GX Device Receiver Pins and GT
Device Power Pins
May 2011
Pin Location
Stratix V GX Device Pin Name
GX Receiver Channels
Stratix V GT Device Pin Name
GT Transceivers
AL3
GXB_RX_R2n, GXB_REFCLK_R2n
VCCL_GTBR0
AL4
GXB_RX_R2p, GXB_REFCLK_R2p
VCCL_GTBR0
AE3
GXB_RX_R8n, GXB_REFCLK_R8n
VCCL_GTBR1
AE4
GXB_RX_R8p, GXB_REFCLK_R8p
VCCL_GTBR1
U3
GXB_RX_R14n, GXB_REFCLK_R14n
VCCL_GTBR2
U4
GXB_RX_R14p, GXB_REFCLK_R14p
VCCL_GTBR2
G3
GXB_RX_R20n, GXB_REFCLK_R20n
VCCL_GTBR3
G4
GXB_RX_R20p, GXB_REFCLK_R20p
VCCL_GTBR3
AK1
GXB_RX_R4n, GXB_REFCLK_R4n
VCCR_GXBR0
AK2
GXB_RX_R4p, GXB_REFCLK_R4p
VCCR_GXBR0
AC3
GXB_RX_R10n, GXB_REFCLK_R10n
VCCR_GXBR1
AC4
GXB_RX_R10p, GXB_REFCLK_R10p
VCCR_GXBR1
R3
GXB_RX_R16n, GXB_REFCLK_R16n
VCCR_GXBR2
R4
GXB_RX_R16p, GXB_REFCLK_R16p
VCCR_GXBR2
D1
GXB_RX_R22n, GXB_REFCLK_R22n
VCCR_GXBR3
D2
GXB_RX_R22p, GXB_REFCLK_R22p
VCCR_GXBR3
AT1
GXB_RX_R1n, GXB_REFCLK_R1n
VCCT_GXBR0
AT2
GXB_RX_R1p, GXB_REFCLK_R1p
VCCT_GXBR0
AF1
GXB_RX_R7n, GXB_REFCLK_R7n
VCCT_GXBR1
AF2
GXB_RX_R7p, GXB_REFCLK_R7p
VCCT_GXBR1
V1
GXB_RX_R13n, GXB_REFCLK_R13n
VCCT_GXBR2
V2
GXB_RX_R13p, GXB_REFCLK_R13p
VCCT_GXBR2
K1
GXB_RX_R19n, GXB_REFCLK_R19n
VCCT_GXBR3
K2
GXB_RX_R19p, GXB_REFCLK_R19p
VCCT_GXBR3
Altera Corporation
Migration Between Stratix V GX and Stratix V GT Devices
Page 4
Differences Between Stratix V GX and Stratix V GT Devices
The transmitter pins of the eight Stratix V GX transceiver channels are not connected
in Stratix V GT devices. Table 4 lists these pin locations. Leave these pins floating; do
not use in your PCB design.
Table 4. Migrated Pin Locations and Functions of Stratix V GX Device Receiver Pins and GT
Device Floating Pins
Pin Location
Stratix V GX Device Pin Name
GX Receiver Channels
Stratix V GT Device Pin Name
AR3
GXB_TX_R1n
Not Connected (NC)
AR4
GXB_TX_R1p
NC
AN3
GXB_TX_R2n
NC
AN4
GXB_TX_R2p
NC
AK5
GXB_TX_R4n
NC
AK6
GXB_TX_R4p
NC
AF5
GXB_TX_R7n
NC
AF6
GXB_TX_R7p
NC
AD5
GXB_TX_R8n
NC
AD6
GXB_TX_R8p
NC
AB5
GXB_TX_R10n
NC
AB6
GXB_TX_R10p
NC
V5
GXB_TX_R13n
NC
V6
GXB_TX_R13p
NC
T5
GXB_TX_R14n
NC
T6
GXB_TX_R14p
NC
P5
GXB_TX_R16n
NC
P6
GXB_TX_R16p
NC
K5
GXB_TX_R19n
NC
K6
GXB_TX_R19p
NC
J3
GXB_TX_R20n
NC
J4
GXB_TX_R20p
NC
E3
GXB_TX_R22n
NC
E4
GXB_TX_R22p
NC
Migration Between Stratix V GX and Stratix V GT Devices
May 2011 Altera Corporation
Altera Corporation
Table 5. Pin Map of Stratix V GX and Stratix V GT Migration (Part 1 of 2)
Stratix V GX Pin Map
A
B
C
D
E
F
G
H
J
K
L
M
N
P
R
T
U
Y
1
2
3
4
5
6
1
2
3
4
5
6
—
GND
GND
—
GND
—
A
—
GND
GND
—
GND
—
GND
GND
GND
GND
GXB_RX_R23n GXB_RX_R23p
GND
GND
GXB_RX_R22n GXB_RX_R22p
GND
GND
GXB_RX_R21n GXB_RX_R21p
GND
GND
GXB_TX_R21n GXB_TX_R21p
GND
GND
GXB_RX_R19n GXB_RX_R19p
GND
GND
GXB_RX_R17n GXB_RX_R17p
GND
GND
GXB_RX_R15n GXB_RX_R15p
GND
GND
GXB_TX_R15n GXB_TX_R15p
GND
GND
GXB_RX_R13n GXB_RX_R13p
GND
GND
GXB_RX_R12n GXB_RX_R12p
GXB_TX_R23n GXB_TX_R23p
GND
GND
GXB_TX_R22n GXB_TX_R22p
GND
GND
GXB_RX_R20n GXB_RX_R20p
GND
GND
GXB_TX_R20n GXB_TX_R20p
GND
GND
GXB_RX_R18n GXB_RX_R18p
GND
GND
GXB_TX_R17n GXB_TX_R17p
GND
GND
GXB_RX_R16n GXB_RX_R16p
GND
GND
GXB_RX_R14n GXB_RX_R14p
GND
GND
GXB_TX_R12n GXB_TX_R12p
GND
AA
GND
GND
AB
GXB_RX_R9n
GXB_RX_R9p
AC
GND
GND
AD
GXB_TX_R9n
GXB_TX_R9p
GND
AE
GND
GND
GXB_RX_R8n
GND
GXB_RX_R11n GXB_RX_R11p
GND
GND
GXB_RX_R10n GXB_RX_R10p
GND
GND
B
GXB_RX_R23n
GXB_RX_R23p
GND
—
C
GND
GND
GND
GND
GND
GND
—
D
GXB_VCCR
GXB_VCCR
GND
—
GND
GND
GND
—
E
GND
GND
—
NC
NC
GND
GND
—
F
GTB_RX_R3n
—
GTB_RX_R3p
GND
GND
GND
—
GXB_TX_R23n GXB_TX_R23p
GND
—
G
GND
GND
GTB_VCCL
GTB_VCCL
GND
—
GND
—
H
GTB_TX_R3n
GTB_TX_R3p
GND
GND
GND
—
GND
GND
GND
GXB_TX_R19n GXB_TX_R19p
GND
GND
GXB_TX_R18n GXB_TX_R18p
GND
GND
GXB_TX_R16n GXB_TX_R16p
GND
GND
GXB_TX_R14n GXB_TX_R14p
GND
GND
GXB_TX_R13n GXB_TX_R13p
GND
GND
GXB_TX_R11n GXB_TX_R11p
GND
GND
GXB_TX_R10n GXB_TX_R10p
J
GND
GND
NC
NC
GND
K
GXB_VCCT
GXB_VCCT
GND
GND
NC
NC
L
GND
GND
GND
GND
M
GXB_RX_R17n
GXB_RX_R17p
N
GND
GND
P
GTB_RX_R2n
GTB_RX_R2p
GND
GND
NC
NC
R
GND
GND
GXB_VCCR
GXB_VCCR
GND
GND
GXB_RX_R18n GXB_RX_R18p
GND
GND
GXB_TX_R17n GXB_TX_R17p
GXB_TX_R18n GXB_TX_R18p
GND
GND
T
GTB_TX_R2n
GTB_TX_R2p
GND
GND
NC
NC
U
GND
GND
GTB_VCCL
GTB_VCCL
GND
GND
GND
GND
V
GXB_VCCT
GXB_VCCT
W
GND
GND
GXB_TX_R12n GXB_TX_R12p
GND
GND
NC
NC
GND
GND
Y
GXB_RX_R12n
GXB_RX_R12p
AA
GND
GND
AB
GTB_RX_R1n
GTB_RX_R1p
GND
GND
NC
NC
GXB_VCCR
GXB_VCCR
GND
GND
GXB_RX_R11n GXB_RX_R11p
GXB_TX_R11n GXB_TX_R11p
GND
GND
GND
GND
AC
GND
GND
GND
GXB_TX_R8n
GXB_TX_R8p
AD
GTB_TX_R1n
GTB_TX_R1p
GND
GND
NC
NC
GXB_RX_R8p
GND
GND
AE
GND
GND
GTB_VCCL
GTB_VCCL
GND
GND
AF
GXB_RX_R7n
GXB_RX_R7p
GND
GND
GXB_TX_R7n
GXB_TX_R7p
AF
GXB_VCCT
GXB_VCCT
GND
GND
NC
NC
AG
GND
GND
GXB_TX_R6n
GXB_TX_R6p
GND
GND
AG
GND
GND
GXB_TX_R6n
GXB_TX_R6p
GND
GND
AH
GXB_RX_R6n
GXB_RX_R6p
GND
GND
GXB_TX_R5n
GXB_TX_R5p
AH
GXB_RX_R6n
GXB_RX_R6p
GND
GND
GXB_TX_R5n
GXB_TX_R5p
AJ
GND
GND
GXB_RX_R5n
GXB_RX_R5p
GND
GND
AJ
GND
GND
GXB_RX_R5n
GXB_RX_R5p
GND
GND
AK
GXB_RX_R4n
GXB_RX_R4p
GND
GND
GXB_TX_R4n
GXB_TX_R4p
AK
GXB_VCCR
GXB_VCCR
GND
GND
NC
NC
AL
GND
GND
GXB_RX_R2n
GXB_RX_R2p
GND
GND
AL
GND
GND
GTB_VCCL
GTB_VCCL
GND
GND
GXB_RX_R3p
GND
GND
GND
GND
AM
GTB_RX_R0n
GTB_RX_R0p
GND
GND
GND
GND
AM GXB_RX_R3n
Page 5
Migration Between Stratix V GX and Stratix V GT Devices
V
W
Stratix V GT Pin Map
Differences Between Stratix V GX and Stratix V GT Devices
May 2011
Table 5 lists the pin map of the package migration between a Stratix V GX device and a Stratix V GT device. The migrated pins
in Table 2 on page 2 are highlighted in pink. The migrated pins in Table 3 on page 3 are highlighted in gray. The migrated pins
in Table 4 on page 4 are highlighted in light blue.
Stratix V GX Pin Map
1
2
3
4
Page 6
Migration Between Stratix V GX and Stratix V GT Devices
Table 5. Pin Map of Stratix V GX and Stratix V GT Migration (Part 2 of 2)
Stratix V GT Pin Map
5
6
1
2
3
4
5
6
—
AN
GND
GND
GXB_TX_R2n
GXB_TX_R2p
GND
—
AN
GND
GND
NC
NC
GND
AP
GXB_TX_R3n
GXB_TX_R3p
GND
GND
GND
—
AP
GTB_TX_R0n
GTB_TX_R0p
GND
GND
GND
—
AR
GND
GND
GXB_TX_R1n
GXB_TX_R1p
GND
—
AR
GND
GND
NC
NC
GND
—
AT
GXB_RX_R1n
GXB_RX_R1p
GND
GND
GND
—
AT
GXB_VCCT
GXB_VCCT
GND
GND
GND
—
AU
GND
GND
GXB_TX_R0n
GXB_TX_R0p
GND
—
AU
GND
GND
GXB_TX_R0n
GXB_TX_R0p
GND
—
AV
GXB_RX_R0n
GXB_RX_R0p
GND
GND
GND
GND
AV
GXB_RX_R0n
GXB_RX_R0p
GND
GND
GND
GND
AW
—
GND
GND
—
—
—
AW
—
GND
GND
—
—
—
Differences Between Stratix V GX and Stratix V GT Devices
May 2011 Altera Corporation
Document Revision History
Page 7
Document Revision History
Table 6 lists the revision history for this application note.
Table 6. Document Revision History
Date
May 2011
May 2011
Version
1.0
Altera Corporation
Changes
Initial release.
Migration Between Stratix V GX and Stratix V GT Devices
Page 8
Migration Between Stratix V GX and Stratix V GT Devices
Document Revision History
May 2011 Altera Corporation