Datasheet

SMB Type Coaxial Connector
27DP Series
FEATURE
■ 27DP series are connectors produced based
on SMB type (Sub Miniature type B) specified
in MIL-PRF-39012.
■ 27DP is super small size coaxial cable
connectors for 50 Ω group corresponding to
minimization of communication equipment.
■ Connection method is push on type, and
Dpcosclaw
P_lec
fixing method cable is by crimping or soldering.
DC to 2GHz
CONFORMING STANDARD
Af_p_arcpgqrga
Gkncb_lac
JIS-C-5415、MIL-PRF-39012、DSP-C-6205
50 Ω
SPECIFICATIONS
Characteristic Impedance
50 Ω
Dielectric Withstanding Voltage 1,000V AC(r.m.s.) for 1minute
Insulation Resistance
1,000M Ω min. at 500V DC
Contact Resistance
6m Ω max.
V.S.W.R.
1.2 max.(DC to 2GHz)
* The specifications are typical but may not apply to all connectors. Please check
the specifications on each item with its drawing from us when you use.
RoHS
Compliant
Compliant
MATERIAL/FINISH
Item
Material / Finish
Shell (Body)
Copper Alloy / Au or Ni Plating
Contact (Male)
Copper Alloy / Au Plating
Contact (Female)
Copper Alloy / Au Plating
Insulator
PTFE
※ Please ask us for the cable assemblies to assure its performance.
◎ Specifications and/or dimensions in this catalog are subject to change without notice.
Your checking the latest specifications with our drawings would be highly appreciated.
20111110
http://www.ddknet.co.jp
27DP Series
Unit:mm
○ Plug
Crimp Type
Applicable
Cable
φ6
φA
Part Number
27DP-P-1.5QEV-AA-CF
L
27DP-P-1.5QEW-AA-CF
1.5DS-QEHV
1.5D-QEV
1.5D-2W
1.5D-QEW
Finish
Assembly
Outer
Center Instruction Crimp Tool
Conductor Conductor
φA
L
4.8
17.5
Ni
Au
4.8
17.5
Ni
Au
CR-H-1160
1
CR-H-1160
27DP-SP-1.5DHQS-CR1-CF
1.5D-HQ•SUPER
4.8
18.1
Ni
Au
CR-H-1156
27DP-SP-2.5DHQS-CR1-CF
2.5D-HQ•SUPER
5.9
18.2
Ni
Au
CR-H-1163
Finish
Outer
Center
Conductor
Conductor
Applicable
Cable
Part Number
φ6
φ4
Semi-Flexible Cable Type
27DP-SP-FCCAV1-SO-CF
FCCAVG1
Ni
Assembly
Instruction
Au
12.1
○ Right Angle Plug
Crimp Type
Applicable
Cable
14
Part Number
27DP-LP-0.8DW-CR1-CF
0.8D-QEW
1.5DS-QEHV
27DP-LP-1.5QEV-AA-CF
1.5D-QEV
27DP-LP-1.5QEW-AA-CF
φA
1.5D-QEW
Finish
Assembly
Instruction
φA
Outer
Conductor
Center
Conductor
3.4
Ni
Au
CR-H-K0012-04
4.8
Ni
Au
CR-H-1160
4.8
Ni
Au
CR-H-1160
Crimp Tool
13.2
□6
Applicable
Cable
Part Number
14
27DP-LP-1.5DW-CR1-CF
1.5D-QEW
1.5D-HQ•SUPER
27DP-LP-1.5DHQS-CR1-CF
1.5D-QEV
2.5D-HQ•SUPER
27DP-LP-2.5DHQS-CR1-CF
2.6D-XFV-A
φA
L1
◎ Specifications and/or dimensions in this catalog are subject to change without notice.
Your checking the latest specifications with our drawings would be highly appreciated.
http://www.ddknet.co.jp
2
Finish
Assembly
Crimp Tool
Center
Instruction
Conductor
φA
L1
Outer
Conductor
4.8
10.0
Ni
Au
4.8
10.0
Ni
Au
CR-H-1156
5.9
11.0
Ni
Au
CR-H-1163
2
CR-H-1156
27DP Series
Unit:mm
○ Right Angle Plug
Semi-Flexible Cable Type
Applicable
Cable
27DP-LP-FCCAV1-SO-1-CF
FCCAVG1
Finish
Outer
Center
Conductor Conductor
Ni
Assembly
Instruction
Au
9.3
Part Number
9.7
○ Bulkhead Jack
Crimp Type
Part Number
Applicable
Cable
27DP-BJ-1.5DW-CR1-CF
1.5D-QEW
Finish
Outer
Center
Conductor Conductor
Ni
Assembly
Instruction
Au
Crimp Tool
CR-H-1156
+0.1
+0.1
3.2 0
φ7.9
φ6
1.2 0
.1
+00
2.5 以下
.2
φ5
8
19.4
Panel Mounting Dimensions
Semi-Flexible Cable Type
Applicable
Cable
Part Number
27DP-BJ-FCCAV1-SO-CF
FCCAVG1
Finish
Outer
Center
Conductor
Conductor
Ni
Au
+0.1
+0.1
3.2 0
φ7.9
φ6
1.2 0
.1
+00
2.5 以下
.2
φ5
3.43
14.3
Panel Mounting Dimensions
◎ Specifications and/or dimensions in this catalog are subject to change without notice.
Your checking the latest specifications with our drawings would be highly appreciated.
http://www.ddknet.co.jp
3
Assembly
Instruction
27DP Series
Unit:mm
○ Receptacle
Finish
Part Number
Outer
Conductor
Center
Conductor
Ni
Au
2.54 0.05
27DP-SR-PC-1-CF
4-□0.7
5.08 0.1
7.3
□5.7
9.8
+0.1
0
5
5−φ1.2
2.54 0.05
5.08 0.1
5.9
PCB Mounting Dimensions
φ3.08
φ1
4−φ2.4
5.9
Finish
Outer
Center
Conductor
Conductor
Part Number
27DP-SR-1-CF
Ni
Au
1.7
9.5
□9.5
4
3
16.5
Finish
Outer
Center
Conductor
Conductor
Part Number
5.9
27DP-SR-2-CF
Ni
φ3.4
1.7
4−φ2.4
5.9
1.7
9.5
□9.5
0.05
+0.1
0
+0.1
0
5.9
φ1
φ3.08
4-φ2.4
Au
1.5
12.7
5.9
0.05
Panel Mounting Dimensions
Finish
Part Number
2−φ2.
75
φ1
2-φ2.75
9.5
+0.1
0
15.5
φ3.4
0.1
4
12.2
2
6.1
1.65
5.8
0.05
0.05
φ3.08
12.2
φ16.8
27DP-SR2-3-CF
Panel Mounting Dimensions
◎ Specifications and/or dimensions in this catalog are subject to change without notice.
Your checking the latest specifications with our drawings would be highly appreciated.
http://www.ddknet.co.jp
4
Outer
Conductor
Center
Conductor
Ni
Au
27DP Series
Unit:mm
○ Right Angle Receptacle
Finish
27DP-LR-PC-1-CF
9.9
4.55
Part Number
Outer
Conductor
Center
Conductor
Ni
Au
2.5
※ cheap version includes die-casting 27DP-LR-PC-14,
(12)
Finish
Part Number
Outer
Conductor
Center
Conductor
Ni
Au
27DP-LR-PC-14
2.54 0.05
(9.9)
7.4
(11.1)
5.08 0.1
2.5
4.55
※ low cost product using the press die-casting method
(φ1)
+0.1
5-φ1.2 0
2.54 0.05
5.08 0.1
PCB Mounting Dimensions
3.45
6.3
(6.6)
Finish
Part Number
0.3
27DP-LR-PS
0.05
0.05
Au
Au
※ low cost product using the press die-casting method
1.55
2.1
1.8
Center
Conductor
0.05
6.52
0.05
1.55
□5.92
0.05
1
3.42
1.8
(φ1)
0.05
1
(1.76)
0.05
(12.9)
Outer
Conductor
0.05
(7.1)
Finish
Part Number
0.3
2-φ1
0.5
3.45
6.3
PCB Land Reference Dimensions
4.92
27DP-LR-PS-1
Outer
Conductor
Center
Conductor
Au
Au
3.26
φ1.2
0.05
※ low cost product using the press die-casting method
0.05
4.92
3.42
6.52
0.05
1.55
□5.92
0.05
1
(φ1)
0.05
1.55
0.05
0.05
0.05
2.1
1.8
1.8 0.05
1
(1.76)
0.05
(12.9)
PCB Land Reference Dimensions
◎ Specifications and/or dimensions in this catalog are subject to change without notice.
Your checking the latest specifications with our drawings would be highly appreciated.
http://www.ddknet.co.jp
5
27DP Series
Unit:mm
○ Bulkhead Receptacle
Finish
Part Number
φA
φB
C
D
L
Outer
Conductor
Center
Conductor
27DP-BR-9-CF
7.0
0.5
27DP-BR-11-CF
6.2
0.8
2.2
6.0
12.9
Ni
Au
3.0
5.4
13.7
Ni
Au
φB
φA
M5 0.
5
1 2.3
L
C
D
◎ Specifications and/or dimensions in this catalog are subject to change without notice.
Your checking the latest specifications with our drawings would be highly appreciated.
http://www.ddknet.co.jp
6
27DP Series
Unit:mm
○ Assembly Instruction (1)
Parts Configuration
Ferrule
Boot
Insulator
①
Outer Conductor
Contact
Center Conductor
Pre-soldering
① Show it to illustration dimensions through a boot
to a cable.
(Note) Be careful about the directionality of the ferrule.
(Note) Please be careful to not damage the outer
conductor, insulator and center conductor.
Pre-soldering the center conductor.
2
Boot
1.5
Cable
Ferrule
4
Contact
②
No gap
② Soldering cable inside conductor and a contact.
(Note) Please be careful to not deform the insulator
by heat.
(Note) When the solder is stick out, please shave
the extra solder.
Soldering
→
③
Body
③ Spread the tip of the outside conductor.
Spread the tip
④
④ Insert a cable in body assembling and cover with
the ferrule which let go through beforehand on an
outside conductor, Crimp.
(Note)The thing by which a gap between the body
assembly ferrule is less than 0.5.
Crimping Dies
A-R
1.72∼2.14
(body assembling - contact interval)
⑤
⑤ Cover the boot on the ferule. Boot
◎ Specifications and/or dimensions in this catalog are subject to change without notice.
Your checking the latest specifications with our drawings would be highly appreciated.
http://www.ddknet.co.jp
7
27DP Series
Unit:mm
○ Assembly Instruction (2)
Parts Configuration
Plate
Body
Ferrule
The cable length required for the cable assembly. L
L=L1+0.6
L1
L=L2-2.5
L2
①
Ferrule
① Insert the ferrule into the cable.
Cable
Insulator
Center Conductor
Outer Conductor
Pre-soldering
②
② Handle a cable end face to illustration dimensions.
2
0.2
5
0.2
(Note)Please be careful to not damage the outer
conductor and center conductor. Pre-solder the center conductor.
8.6
0.2
③ Disentangle an outside conductor uniformly and
③
spread the tip.
Spread the tip
④
Cable outside conductor
stab expectation
Contact
slit part
Body assembly
Crimping Dies
A-R1
Soldering
Contact
⑤
④ Insert body assembling between an outside
conductor, insulators.
(Note)Internal conductor in a contact slit more than
half Being satisfied.
(Note)Aya cover evenly over the first knurling the outer
conductor. cover with the ferrule which let go
through beforehand on an outside conductor and
knock it against body system and crimp it.
(Note) The gap between body and ferrule is within 0.5.
Solder cable inside conductor and a contact.
(Note) Please be careful to not deform the insulator by heat.
0.5 max.
0.15∼0.3
Height after
press-in
(gap between ferrule and body)
⑤ Compress the plate into the body.
◎ Specifications and/or dimensions in this catalog are subject to change without notice.
Your checking the latest specifications with our drawings would be highly appreciated.
http://www.ddknet.co.jp
8