SSMB series product data PDF

Low Profile Push-On Coaxial Connector
SSMB Series
Frequency
Range
DC to 2GHz
Characteristic
Impedance
50 Ω
Lock Type
Push On
FEATURE
・ Low profile coaxial connector with push on lock
coupling which is conforms to IEC Pub. 169-19.
・ Mating heights from PCB are available in
conbination SP and LR (6mm) and conbination
LP and SR(11mm).
CONFORMING STANDARD
IEC-Pub. 169-19
SPECIFICATIONS
Characteristic Impedance
50 Ω
Rated Voltage
250VAC(r.m.s.)
Dielectric Withstanding Voltage 500V AC(r.m.s.)for1 minute
Insulation Resistance
1.000M Ω Mim. at 250V DC
Contact Resistance
Center Conductor 7.5m Ω Max.
Outer Conductor 2.5m Ω Max.
V.S.W.R.
1.3 max. at DC to 2GHz
Operating Temperature
-40 〜 +85℃
* The specifications are typical but may not apply to all connectors. Please check the specifications on each item with its drawing from us when you use.
MATERIAL/FINISH
Item
Shell (Body)
Contact (Male)
RoHS
Compliant
Compliant
Material / Finish
Copper Alloy / Au Plating
Copper Alloy / Au Plating
Contact (Female) Copper Alloy / Au Plating
Insulator
121226
PTFE
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without a previous notice.
Moreover, the characteristic and the specification of the published product are the reference values.
Please confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
SSMB Series
Unit:mm
φA
○ Plug Connector
φ5
L
φA
L
Outer
Finish
Center
Conductor
Conductor
0.8D-QEV
5.0
13.9
RG-196A/U
5.0
17.3
Au
Au
1
CR-H-1164
SSMB-SP-1.5QEW-CF
1.5D-QEW
5.5
15.8
Au
Au
2
CR-H-1133
SSMB-SP-85-SO-CF
Outer
Finish
Center
Conductor
FCCAVG1
Conductor
Au
Au
Crimp Tool
SSMB-SP-196U-CF
Applicable
Cable
Au
Assembly
Instruction
SSMB-SP-0.8DV-CR-CF
Part Number
10.5
Dimensions
Applicable
Cable
Part Number
CR-H-13510
Assembly
Instruction
Au
○ Right Angle Plug Connector
5.0
C
A
Dimensions
Part Number
Applicable
Cable
A
B
C
SSMB-LP-0.8DQEV-CF
0.8D-QEV
7.73
3.0
13.5
SSMB-LP-196U-CF
RG-196A/U
7.73
3.0
SSMB-LP-1.5QEW-CF
1.5D-QEW
8.48
4.5
Finish
Outer
Center
Conductor Conductor
Au
Au
1
CR-H-1164
13.5
Au
Au
1
CR-H-1164
12.4
Au
Au
2
CR-H-1133
φB
5.0
Applicable
Cable
8
Part Number
9.05
φ4
SSMB-LP-85-SO-CF
FCCAVG1
Finish
Outer
Center
Conductor
Conductor
Au
Au
Assembly
Instruction
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without a previous notice.
Moreover, the characteristic and the specification of the published product are the reference values.
Please confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
2
Assembly
Crimp Tool
Instruction
SSMB Series
Unit:mm
○ Receptacle Connector
φ0.65
4-0.6
2.5
SSMB-SR-PC-CF
5.2
□5
φ0.65
4-□0.6
5.2
2.5
φ0.65
(11.73)
4-□0.6
5-φ1.2
Conductor
Conductor
Au
Au
Finish
Outer
Part Number
SSMB-LR-PC-CF
φ0.65
□5
Finish
Center
9.23
2.5
0.05
Au
Center
Conductor
Conductor
Au
Au
0.05
11.5
0.05
2.2
4.4
0.05
0.05
5-φ1.2
0.05
2.2
4.4
0.05
2.2
0.05
Au
5.2
(11.73)
4-□0.6
4.4
Conductor
Outer
SSMB-SR-PC-1-CF
9.23
2.5
5.7
5
Center
Conductor
8.5
Part Number
5
Finish
Outer
Part Number
取付穴参考寸法
0.05
.8
φ2.15
φ0.65
4.4
2−φ2.75
6
φ1
2.2
0.05
6.1
12.2
取付穴参考寸法
PCB Mounting
Dimensions
5
1.5
6.7
(13.7)
2−φ2.75
7
5.8
.8
6
φ1
Outer
Part Number
12.2
φ2.15
φ0.65
SSMB-SR2-CF
Conductor
Conductor
Au
Au
0.1
1.5
6.7
(13.7)
5.8
+0.1
φ2.4 0
0.05
5
12.2
7
6.1
0.05
6.1
2-φ2.75
Finish
Center
PCB Mounting Dimensions
2-φ2.75
0.1
取付穴参考寸法
0.05
+0.1
φ2.4 0
12.2
http://www.ddknet.co.jp
6.1
0.05
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without a previous notice.
Moreover, the characteristic and the specification of the published product are the reference values.
Please confirm the content with the latest delivery specifications when you use the product.
3
SSMB Series
Unit:mm
○ Assembly Instruction(1)
①
① Cable cutting
Heat-shrinkable Tube
Insert the heat-shrinkable tube and ferule into
RG-196A/U
Ferule
the cable and cut the cable as left figure.
Outer Conductor
Insulator
Center Conductor
RG-196A/U
Ferule
RG-196A/U
Heat-shrinkable Tube
Ferule
RG-196A/U
Heat-shrinkable Tube
Ferule
Heat-shrinkable Tube
Outer Conductor
Insulator
Outer Conductor
Part Number
A
Outer
Conductor
Center Conductor
Insulator
B Insulator
SSMB-SP-196U-CF
Center Conductor
Center Conductor
C
SSMB-LP-196U-CF
A
SSMB-LP-0.8DQEV-CF
A B
Body
A
B
C
B
B
C
6
8.5
10.5
6
8.5
9.5
6
8.5
9.5
C
Body
C
②
A
Body
Body
② Crimping outer conductor
Stretch the outer conductor of cable, insert
(SP)
the body and crimp the ferule on the outer
(LP)
conductor by dies.
0∼1
0∼1
0.5∼1
Dies
Dies
Dies
0.5∼1
Soldering
Soldering
③
Dies Dies
0.5∼1
Dies
Dies
0∼1
Dies
0∼1
0.5∼1
Center conductor must be
located between contact slit.
Center conductor must be
located between contact slit.
Center conductor must be
Center located
conductor
must be
between
contact slit.
located between contact slit.
Contact
③ Soldering contact
Contact
Solder the contact with center conductor
Soldering
No gap Contact
Soldering
Contact
Soldering
No gap
(SP)
④
0∼1
(LP)
(LP)
(LP)
0∼1
0∼10∼1
(SP)
(SP)
(SP)
No gap
No gap
(SP)
(SP)
(SP)
Heat-shrinkable Tube
Soldering
Soldering
Soldering
Contact
Press the plate more than 0.1.
(LP)
Contact
Insulator
Press the plate more than 0.1.
Contact
Contact
Press the plate more than 0.1.
Press the plate more
than 0.1.
(LP)
Insulator
Plate
Insulator
Insulator
Heat-shrinkable Tube
Heat-shrinkable Tube
Heat-shrinkable Tube
of the cable.
(LP)
(LP)
Insert the insulator and screw the shell.
Plate
Plate
Connector
④ Assemble connector
(Recommended screw torque : 49N/㎝).
Plate
In case of LP style, insert the plate and press it
Heat-shrinkable Tube
into the connector.
Cover the root of connector with heat-shrinkable
Connector
Connector
Connector
Heat-shrinkable Tube
tube and heat shrink.
Heat-shrinkable Tube
Heat-shrinkable Tube
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without a previous notice.
Moreover, the characteristic and the specification of the published product are the reference values.
Please confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
4
SSMB Series
Unit:mm
○ Assembly Instruction (2)
①
① Removing outer jacket
Outer Conductor
Removing outer jacket as left figure.
Outer Conductor
8
Outer Jacket
8 Conductor
Ferule Outer
Outer Jacket
②
Outer Conductor
Outer Jacket
Insert ferule into the cable, stretch the outer
Ferule
8
Insulator
Outer Jacket
Ferule
Center Conductor
Insulator
A
A
Dies
Body Surface
(SP)
Dies Surface
Dies
DiesSurface
Surface
Body
④ (SP)
Body Surface
Dies Surface
B
(LP)
Center Conductor
Center Conductor
(LP)
0.5∼1
Soldering
DIes Surface
Dies
Body Surface
No gap
Soldering
Contact
Contact
No
gap
(SP)
(SP)
No gap
Contact
Contact
Insulator
Connector
④ Crimping body
surface and
⑤ Soldering contact
Soldering
Soldering the contact with center conductor
Soldering
(LP)
Press the plate more than 0.1
Soldering
(LP)
of the cable
Press the plate more than 0.1
(LP)
Press the plate more than 0.1
(LP)
Press the plate more than 0.1
Plate
⑥ Assemble connector
Insert the insulator and screw the connector.
Plate
Connector
Connector
4.7
Soldering
Insulator
Contact
Insulator
Contact
Insulator
5.2
2.8
Center Conductor must be
located between contact slit.
No gap
(SP)
2.8
SSMB-LP-1.5QEW-CF
Center Conductor must be
located DIes
between
contact slit.
Surface
Center
BodyConductor
Surface must be
located between contact slit.
Contact
Soldering
B
SSMB-SP-1.5QEW-CF
Dies
DIes Surface
Insert the body and crimp it by dies.
Body Surface
Center Conductor
be
Crimping body should be equal to body
DIesmust
Surface
located between contact slit.
Body
Surface
Dies
dies surface.
Contact
Soldering
A
Dies
0.5∼1
Center Conductor
0.5∼1
(SP)
Part Number
(LP)
0.5∼1
⑥
cable as left figure.
(LP)
Center Conductor
Dies
Body Surface
⑤
Cut the center conductor and insulator of the
Center Conductor
B
B
A
Dies
③ Cutting cable
Center Conductor
B
A
Insulator
(SP)
(SP)
the sleeve
Sleeve
Center Conductor
Sleeve
Insulator
Insulator
Dies Surface
Cut off the outer conductor of the cable along
Sleeve
Insulator
③
conductor of the cable and insert sleeve.
Sleeve
Insulator
Insulator
② Insert ferule and sleeve
8
Ferule
(Recommended screw torque : 49N/㎝)
Plate
In case of LP style, insert the plate and press it
into the connector. Plate
Connector
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without a previous notice.
Moreover, the characteristic and the specification of the published product are the reference values.
Please confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
5