SMA Style Coaxial Connector DM Series Characteristic Impedance 50 Ω OUTLINE Lock Type Screw DM series is a SMA connector which conforms to MIL-C-39012. It is compact and tough 50Ω coaxial connector which designed for compact-sized and higher frequency communication device. Screw lock coupling enables reliable connection. Compatible to other SMA style connectors. Crimp, soldering and clamp types are available. APPLICATIONS CONFORMING STANDARD Base Station, Telecom, Wireless LAN, GPS MIL-C-39012 SPECIFICATIONS Characteristic Impedance 50 Ω Dielectric Withstanding Voltage 1000V AC(r.m.s.) for1 minute Insulation Resistance 1000M Ω Mim. at 500V DC Contact Resistance 3m Ω Max. V.S.W.R. 1.05 + 0.01 x f (GHz) * The specifications are typical but may not apply to all connectors. Please check the specifications on each item with its drawing from us when you use. MATERIAL/FINISH Item Shell (Body) RoHS Compliant Compliant Material / Finish Copper Alloy or Stainless Steel / Au, Ag or Ni Plating Coupling Ring Copper Alloy or Stainless Steel / Au, Ag or Ni Plating Contact Copper Alloy / Au or Ag Plating Insulator PTFE ※ We are providing the standard item on this catalogue. Other materal(Brass, Stainless steel) are also available. Please contact our sale office. ※ Notice for mating connectors When screwng up the coupling ring, please screw up by hand and tighten by toque wrench. ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. 110526 http://www.ddknet.co.jp DM Series Unit:mm ○ Straight Plug Connector Crimp Type φA (L) Outer φ A (L) Cable Size Center Conductor Conductor Coupling Assembly Instruction Crimp Tool DM-P-1.5D2V-CR-BS-CF 1.5D-2V 5.5 17.5 Ni Au Ni 1 CR-H-1100 DM-SP-1.5DHQS-CR1-CF 1.5D-HQ・SUPER 4.8 19.3 Ni Au Ni 2 CR-H-1156 DM-P-1.5DQEW-CF 1.5D-QEW 4.8 19.0 Ni Au Ni 3 CR-H-1156 DM-P-58U-CR-BS-CF RG-58A/U 6.25 24.4 Au Au Au 4 CR-H-1105 Coupling Assembly Instruction Crimp Tool Finish Applicable Part Number φA Outer φ A (L) Cable Size DM-SP-2.5DV-CR1-CF Center Conductor Conductor 2.5D-2V 5.9 19.2 Ni Au Ni 5 CR-H-1163 DM-SP-2.5DHQS-CR1-D1-CF 2.5D-HQ・SUPER 5.9 19.0 Ni Au Ni 3 CR-H-1163 DM-SP-2.5DW-CR1-CF 2.5D-2W 5.9 18.8 Passivation Au Passivaion 7 CR-H-1163 3D-2W 7.6 24.2 Au Au 8 CR-H-18293 Coupling Assembly Instruction (L) ☆ Finish Applicable Part Number 2.5D-QEV DM-P-3DW-CR-CF Au for Semi-Rigid, Semi-Flexble Cable φA Part Number (L) Applicable Cable Size UT-85 DM-P-85-SO-BS-2-CF FCCAVG1 Finish 3.5 Cable Size DM-SP-141-SO-2-D1-CF UF141A FCCAVG0 13.7 Ni DM-SP-141-SO-2-D3-CF FCCAVG0 Applicable Cable Size Center Conductor Conductor Ag Ag FCCAVGO-4.6 Part Number Utilize center conductor of the applicable cable DM-P-141-SO-D1-CF Outer Conductor 8.7 Au FCCAVG0 ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 2 Ni Coupling Center Conductor Utilize center conductor of the applicable cable Assembly Instruction Ag Ni Finish (L) UT-141A (L) Au Finish Outer UF-141A (14.2) Center Conductor Conductor Applicable Part Number Outer φ A (L) Coupling Ni Assembly Instruction DM Series Unit:mm ○ Right Angle Plug Connector Crimp Type Finish Applicable Part Number (L1) (L2) Outer (L2) Cable Size DM-LP-1.5DW-CR1-CF Center Conductor Conductor 1.5D-QEW Assembly Crimp Instruction Tool Coupling 17.5 16.1 Ni Au Ni 9 CR-H-1156 DM-LP-2.5DHQS-CR1-CF 2.5D-HQ・SUPER 17.8 17.0 Ni Au Ni 10 CR-H-1163 DM-LP-3D2W-CR1-CF 18.8 21.2 Ni Au Ni 11 CR-H-18923 Coupling Assembly Instruction 3D-2W (L1) for Semi-Rigid, Semi-Flexible Cable (L2) Part Number (L1) (L2) Outer Cable Size DM-LP-85-SO-4-CF (L1) Finish Applicable DM-LP-141-SO-4-D1-CF Center Conductor Conductor UT-85 FCCAVG1 UT-141A FCCAVG0 18.0 11.0 Ni Au Ni 19.0 11.4 Ni Au Ni ○ Jack Connector for Semi-Rigid, Semi-Flexible Cable 9 φA Part Number DM-SJ-141-SO-1-CF (L) DM-SJ-85-SO-CF Applicable Connector UT-141A FCCAVG0 UT-85 FCCAVG1 Finish φA L Outer Center Conductor Conductor 6.4 13.3 Ag Ag 4.0 12.5 Ni Au Assembly Instruction ○ Panel Jack Connector for Semi-Rigid, Semi-Flexible Cable 4-φ2.6 φA 8.60 Part Number DM-PJ-141-SO-DI 1.7 9.55 L 8.60 □12.7 DM-PJ-141-SO-D3-CF +0.1 0 Applicable Cable Size UT-141A FCCAVG0 UT-141A FCCAVGO 4-φ2.75 ☆ 8.60 0.05 UT-85 FCCAVG1 12.7 Ni Au 4.7 12.7 Ni Au 3.4 12.7 Ni Au PCB Mounting Dimensions Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 3 Center 4.7 ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Outer Conductor Conductor 8.60 .5 φ6 DM-PJ-85-SO-D3 L 0.05 .1 +0 0 Finish φA Assembly Instruction DM Series Unit:mm ○ Receptacle Connector Finish 8.64 㱵1.27 4-φ2.7 1.65 B 8.64 9.5 Outer L Center DM-SR-18-CF 4.0 1.5 15.0 Ag Ag DM-SR-20-CF 6.0 1.0 16.5 Ag Ag DM-SR-27-CF 5.0 1.0 15.5 Ag Ag +0.1 4-φ2.75 0 □12.7 L B 8.64 0.05 A A Conductor Conductor +0.1 φ4.2 0 PCB Mounting Dimensions 8.64 0.05 Finish 4-φ2.7 Part Number A Outer L Center Conductor Conductor φ1.27 8.64 DM-SR-23-CF 1.65 A 5,1 14.6 Ag Ag DM-SR-28-CF 6.0 15.5 Ag Ag DM-SR-31-CF 3.0 12.5 Ag Ag +0.1 0 9.5 4-φ2.75 8.64 □12.7 L +0.1 0 8.64 0.05 8.64 0.05 φ4.2 PCB Mounting Dimensions Finish Part Number 4-φ2.7 A B Outer L Center Conductor Conductor DM-SR-1 φ1.27 8.64 φ4.11 2.0 4.0 15.5 Passivation Au DM-SR-15-CF 4.0 8.7 22.2 Ag Ag DM-SR-24-CF 5.0 6.5 21.0 Ag Ag DM-SR-30-CF 4.0 6.5 20.0 Ag Ag 1.65 A B 9.5 8.64 +0.1 0 4-φ2.75 □12.7 L +0.1 0 0.05 8.64 8.64 0.05 φ4.2 PCB Mounting Dimensions Finish Part Number 4-φ2.7 Outer Center Conductor Conductor 8.64 1.7 1.65 9.5 8.7 19.9 Ag +0.1 0 4-φ2.75 +0.1 8.64 φ4.2 0 0.05 φ4.11 DM-SR-19-CF 0.62 □12.7 8.64 0.05 PCB Mounting ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. 8.64 φ4.11 Part Number Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 4 Dimensions Ag DM Series Unit:mm ○ Receptacle Connector .8 16 φ +0.1 2-φ2.75 0 DM-SR2-18-CF Ag Ag 6.1 5.8 9.5 Center Conductor Conductor 0.05 φ1.27 1.65 Outer Part Number 12.2 +0.1 0 .2 φ4 1 6 Finish 0.05 12.2 φ4.11 2-φ2.75 15.5 PCB Mounting Dimensions 16 φ 2-M2.6 0.45 +0.1 .8 0.1 L Outer Center DM-SR2-1-CF 5,1 14.6 Ag Ag 0.05 DM-SR2-1-D1-CF 5.1 14.6 Au Au 6.1 5.8 A Conductor Conductor 12.2 12.2 φ1.27 Part Number 0 .1 1.65 9.5 L A Finish 2-φ2.75 0 φ4 + .2 0 DM-SR2-22-CF 3.1 12.6 Ag Ag B L PCB Mounting Dimensions 16 φ +0.1 0 2-φ2.75 2-φ2.75 .8 0.1 12.2 6.1 5.8 Outer Center Conductor Conductor 0.05 12.2 φ4.11 φ1.27 1.65 9.5 B A +0.1 φ4.3 0 A Finish Part Number L DM-SR2-4-CF 2.5 5.0 17.0 Ni Au DM-SR2-8-CF 4.0 5.5 19.0 Ni Au DM-SR2-8-D1-CF 4.0 5.5 19.0 Au Au DM-SR2-9-CF 1.5 4.0 15.0 Ag Ag DM-SR2-15-CF 1.5 3.2 14.2 Ni Au A B L PCB Mounting Dimensions φ17 4-φ2.75 Finish 1.65 0.1 6.7 DM-SR2-10-CF 6.9 2.9 16.4 Ag Ag DM-SR2-11-CF 4.4 2.9 13.9 Ag Ag PCB Mounting Dimensions +0.1 φ17 2-φ2.75 0 12.2 12.2 2-φ2.7 +0.1 0 6.7 DM-SR2-16-CF 6.11 1.65 9.5 Finish Part Number Outer Center Conductor Conductor 0.05 φ1.27 φ4.2 2 Center Conductor Conductor 9.5 L 5 Outer 0.1 A 6.1 0.05 φ4.2 0 B φ4.11 Part Number 12.2 12.2 +0.1 φ1.27 φ4.11 2-φ2.7 16.5 PCB Mounting Dimensions ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 5 Ni Au DM Series Unit:mm ○ Right Angle Receptacle Connector L B A Finish 8.64 4-φ2.7 Part Number +0.1 0 8.64 □12.7 φ1.27 φ4.11 4-φ2.75 +0.1 0 A B L Outer Center Conductor Conductor DM-LR-7-CF 6.0 2.0 20.5 Ag Ag DM-LR-8-CF 4.0 6.5 23.0 Ag Ag φ4.2 0.05 8.64 8.64 0.05 15.7 12.5 1.65 PCB Mounting Dimensions 16.9 12.5 4.4 1.65 17 Finish 12.22 2-φ2.7 Part Number DM-LR2-CF φ1.27 φ4.11 15.7 Outer Center Conductor Conductor 6.7 2.9 Ag Ag 16.9 9.5 Finish 4.1 5 φ1 6.6 1.7 Part Number 2-M2.6 DM-LR2-2-CF 12.2 19.15 11.2 Center Conductor Conductor .9 φ1.27 Outer Ag Ag 16.9 9.5 Finish 4.1 1.7 Part Number Center Conductor Conductor 6.6 DM-LR2-5-CF Ag Ag 15.7 11.2 φ1.27 .9 15 2-M2.6 φ Outer 12.2 12.2 0.1 +0.1 6.1 0.05 2-φ2.75 0 +0.1 φ4.2 0 PCB Mounting Dimensions 2.54 0.05 3.5 2.54 5 11.5 0.05 φ1.2 10 0.05 Finish 5-φ1.6 Part Number DM-LR-PC-CF 4-□0.92 □6 □5.08 0.05 13.5 PCB Mounting Dimensions ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 6 Outer Center Conductor Conductor Ni Au DM Series Unit:mm ○ Dust Cap Part Number 1/4-36UNS-2B Flat Diameter:8 Part Number DM-RC-2-CF (60) Contact Plating Ni (8.5) (φ2.3) (φ2.5) DM-RC-1-CF Flat Diameter:8 (68.5) ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 7 Contact Plating Ni DM Series Unit:mm ○ Assembly Insutruction(1) Parts Configuration Contact Ferule Body 1 1.The cable length require for cable assembly L1 1 = L1+26mm L2 2 Sheath 2 = L2 -9mm Outer Conductor 8.0 2. Strip the outer jacket at 8.0 0.3mm from edge of cable. When strip the outer jacket, please be carefule to not damage the outer conductor. 0.3 Ferule 3 3. Insert the ferule into the cable as figure 3. Peel the outer conductor and turn down on the ferule Center Conductor After pre-soldering, cut the cable in 2mm ) Insulator 4 ) 2.0 2.8 0.3 0.2 4.5∼5.0 4. Cut the outer conductor, insulator and center conductor as figure 4. Cut the end of outer conductor in same length. When removing the insulator, please be carefule to not damege the center conductor. Soldering 5. Pre-solder the inside of the contact. and solder the center conductor. When the solder swelled bigger than diameter of the contact, shave the exceeding solder by razor. Wipe the flux by alcohol. 5 Contact No gap Crimp Dies 6 Length of sticking out the ferule : 0.5 max. Body 1∼2 6. Insert the contact into the body and push in until the key inside the insulator meet the key way on the contact, And crimp the ferule as figure 6 by crimp tool (CR-H-110/ DDK No.89171). (Note 1)Please crimp the body at 1-2mm from the end of the body. (Note 2)Length of sticking out from the ferule must be within 0.5mm. ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 8 DM Series Unit:mm ○ Assembly Insutruction(2) Parts Configulation Contact Ferule Body 1 1. The cable length require for cable assembly. L = L1-7.7 = L2+11.6 L2 L1 Ferule 1-1.Insert the cable into the ferule. (Note)Please confirm the direction of ferule Cable Insulator with aluminum foil tape 2 Outer Conductor Center Conductor 2-1.Cut the end of cable as fig.2. (Note)Aluminum foil tape can be cut in 5.4mm. (Note)Please be careful to not damage the center conductor and outer conductor of cable. 2-2.Pre-solder up the center conductor of the cable. Pre-soldering (5.4) 8 0.3 (9.5) 2.6 0.3 1.5 0.3 3 Insulator Sheath 3-1.Pick the outer conductor of the cable and turn down to the sheath. 3-2.Cut the aluminum foil tape at the foot of outer conductor turn down. 3-3.Put back and spread the outer conductor as fig.3. Cut the aluminum foil tape Spread the top 4 Soldering No gap 5 Contact 4-1.Solder the center conductor and contact. (Note)Please be careful to not deform the insulator by heat. (Note)When the solder is stick out, please shave the extra solder. Crimping Dies A-R1 5-1.Insert above cable into the connector body. Cover the naked outer conductor with the ferule and crimp the ferule. (Note)Please be careful to not deform the insulator. 0.5 max. (between body and ferule) ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 9 DM Series Unit:mm ○ Assembly Insuruction(3) g Boot Contact Ferule Body 1 1. The cable length require for the cable assembly L=L1-5.7 L1 2 Sheath Outer Conductor Insulator Center Conductor Pre-soldering 4.5 Cable 7.5 11.0 3 1.0 2. Cut the cable as fig.1. (Note)Please be careful to not damage outer conductor, insulator and center conductor. 2-1.Pre-solder the center conductor. (Note) Please be careful to not deform the insulator by heat. Center Conductor 3. Cut the center conductor as fig.3. 2.5 4 Insulator 4. Solder up the contact to the center conductor of Soldering the cable Contact (Note)Please be careful to not deform the insulator by heat. (Note)No gap between contact and insulator. No gap (Note)When the solder is stick out, please shave 5 Insulator Boot Ferule the extra solder. Spread the top 5 Insert the boot and ferule into the cable. (Note)The boot is required DM-P-1.5DQEW only. 5-1.Spread the outer conductor and pick equally. 6 Crimping Dies 6. Insert the above cable into the connector body until strike the top of the cable. 6-1.Covert the ferule on the outer conductor. 6-2.Crimp the ferule. (Crimp Dies:A-R1) (Note)The gap between connector body and ferule is within 0.5mm. 6-3.Cover the boot on the ferule. (Note)DM-P-1.5DQEW only Body A-R1 Body Level out the end of body and the end of crimping dies Ferule ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 10 DM Series Unit:mm ○ Assembly Insutruction(4) Parts Configuration Boot Ferule Contact 1 Body 1. The cable length require for the cable assembly L = L1 ー 7.1 L1 Cable 2. Insert the boot and ferule into the cable. 2 Ferule Boot 3 3. Cut the cable as fig.3. Sheath Outer Conductor Insulator Center Conductor(Note)Please be carefule to not damage the outer Pre-soldering 6.3 0.2 9.0 0.2 2.0 4 conductor , insulator and center conductor. 3-1. Pre-solder the center conductor. (Note)Please be careful to not deform the insulator by heat 0.2 4. Solder up the contact and center conductor. (Note)Please be careful to not deform the insulator Soldering Insulator Contact by heat. (Note)No gap between contact and insulator. No gap 5 6 Spread the top Connector Body 0.1 Ferule (Note)When the solder is stick out, please shave the extra solder. 5. Spread the top of the outer conductor. 5-1. Insert the root of connector body between outer conductor and insulator. (Note)Please do not pick the outer conductor. 0.1 (Gap between body and contact) 6. Insert the connector body until the gap between body and contact is within 0.1 0.1. 6-1. Cover the ferule on the outer conductor and insert the cable until strike the top of the cable. 6-2. While the cable is touch the connector body, crimp the ferule two points. Crimping Dies :F (Note)Crimp point is nearest to the body first. (Note)The gap between body and ferule is within 0.5. (Note)Crimp height is 5.38 ∼ 5.56. (Note)The gap between body and contact is within 0.1 0.1. Crimping Dies 0.5 max. 0.1 0.1 (Gap between body and contact) Measuring position of crimp height 3.0 1.0 7 7.Cover the boot on the ferule. Boot ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 11 DM Series Unit:mm ○ Assembly Instruction(5) Parts Configuration Ferule Heat-shrinkable tube L Contact Body The cable length require for the cable assembly L = L1+6 L1 1. Insert the boot and ferule into the cable. Heat-shrinkable tube Ferule 1 Cable Outer Conductor Insulator Center conductor 2. Cut the cable as fig..2. 2 Pre-soldering to the center conductor of the cable. (Note)Please be careful to not damage outer conductor, insulator and center conductor. +0.3 2.0 -0.5 Sheath 4.5 0.5 +0.5 10.5 0 3 Soldering 3. Solder up the contact with center conductor. (Note)When the solder is stick out, please shave the extra solder. (Note)No gap between contact and insulator. Contact No gap 4 Spread the top 4. Spread the top of the outer conductor. Insert the root of connector body between outer conductor and insulator. 5 Ferule 5. Cover the ferule on the naked outer conductor and crimp. Crimping Dies:RFD-1 0.5 max. (between body and ferule) 6 6. Cover the heat-shrinkable tube on the ferule and heat up the tube. Heat-shirinkable tube ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 12 DM Series Unit:mm ○ Assembly Instruction(6) Parts Configuration Ferule Contact Body 1 1. The cable length require for the cable assembly. L=L1 ー 8 L1 2 Ferule 2. Insert the ferule into the cable. Cable 3 Outer Conductor Aluminum foil tape 5.5 Insulator 3. Cut the cable as fig.2. (Note)Please be carefule to not damage the center conductor and outer conductor. 3-1. Pre-solder the center conductor. (Note)Please be careful to not deform the insulator by heat 0.3 7.0 (8.7) 4 Center conductor (Pre-soldering) Soldering 1.7 Contact 4. Solder up the contact with center conductor. (Note)Please be careful to not deform the insulator by heat. (Note)No gap between contact and insulator. No gap (Note)When the solder is stick out, please shave 5 the extra solder. 5. Spread the top of the outer conductor. 5-1. Insert the root of connector body between outer conductor and aluminum foil tape. (Note)Aluminum foil tape is inserted into the connector body. 5-2. Cover the ferule on the naked outer conductor and crimp the connector body. (Note) The gap between body and ferule is within 0.5. Spread the top Connector Body Crimping Dies RFD-1 Ferule ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 13 DM Series Unit:mm ○ Assembly Insutruction(7) Parts Configuration Heat-shrinkable tube Ferule Contact Body 1. The cable length require for the cable assembly. L = L1 ー 7.0 1 L L1 2 Sheath Outer Conductor Insulator Cable 7.3 (9.5) Center Conductor 2. Cut the cable as fig.2. (Note)Please be careful to not damage the outer conductor, insulator and center conductor. 2-1. Pre-soldering the center conductor. (Note)Please be careful to not deform the insulator by heat 2.3 2.2 Soldering 3 Contact 3-1. Solder up the contact with center conductor. (Note)Please be careful to not deform the insulator by heat. No gap Insulator 4 (Note)No gap between contact and insulator. (Note)When the solder is stick out, please shave the extra solder. Heat-shrinkable tube Ferule Spread the top DIes 4. Insert the heat-shrinkable tube and ferule into the cable. 4-1.Spread the top of outer conductor. 4-2.Insert the root of connector body between outer conductor and insulator. 4-3.Cover the ferule on the naked outer conductor. 4-4.Crimp the ferule. (Crimping Dies : RFD-1) (Note)The gap between connector body and ferule is within 0.5. Ferule 5.Cover the heat-shrinkable tube on the root of the connector body and heat up the tube. 5 Heat-shirinkable tube ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 14 DM Series Unit:mm ○ Assembly Instruction(8) Parts Configuration Boot Contact Ferule Body 1. The cable length require for the cable assembly. L = L1 ー 7.2mm 1 L1 Boot Ferule Outer Conductor 2 2. Insert the boot and ferule into the cable and strip the sheath as fig.2. 12.3 Cable 3 Outer Conductor Insulator Center Conductor 3. Cut the outer conductor, insulator and center Pre-soldering conductor as fig.3. And pre-solder the center conductor. 0 7.0 -0.5 0 +0.5 0 2.0 --0.5 10.3 4 Insulator 4. Solder up the contact with the center conductor. (Note)No gap between contact and insulator. Soldering Contact (Note)When the solder is stick out, please shave the extra solder. No gap 5 Outer Conductor Body 5. Spread the outer conductor and insert into the connector body. Contact Body 6 Ferule 2.18 0.15 6. Cover the ferule on the naked outer conductor and crimp. (Crimping Dies : D-P) 0.5 max. (between body and ferule) Crimping Dies D-P 7 Boot 7. Cover the boot on the root of the connector body. ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 15 DM Series Unit:mm ○ Assembly Instruction(9) Parts Configuration Boot Ferule Plate Body 1 1. The cable length require for the cable assembly. L=L1+14 (mm) L1 Boot Ferule 2 11.0 Cable 2. Insert the boot and ferule into the cable. And cut the sheath as fig.2. 0.5 Outer Conductor Insulator Center Conductor 3 3. Cut the outer conductor, insulator and center conductor as fig.3. And pre-solder the contact. 0 4.0 -0.5 8.5 4 0.25 0 1.6 -0.5 No gap 4. Pick the outer conductor and insert the connector body into the cabe between outer conductor and insulator. Ferule 5 leveling equally 5. Cover the ferule on the naked outer conductor and crimp. (Crimping Dies :A-R1) Crimping Dies(A-R1) 6 6. Solder up the contact and center conductor. (Note)Please be careful to not deform the insulator. Soldering 7 7. Cover the boot on the ferule. Boot 8 Height after press-in 0.3∼0.5 Gap between body and contact 0∼0.25 8. Insert the plate on the top of connector and press-in. Plate ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 16 DM Series Unit:mm ○ Assembly Instruction(10) Parts Configuration Ferule 1 2 Body Blind Screw L L1 1. The cable length require for the cable assembly. L=L1+0.5 Outer Conductor Aluminum foil tape Sheath Center Conductor 2. Cut the cable as fig.2. (Note)Please be careful to not damage the outer conductor and center conductor. 2-1. Pre-solder the center conductor. Pre-soldering 1.8 6.0 Cable 11.0 3 3. Insert the ferule into the cable. Cable 4 Ferule Contact Slit Spread the top Crimping Dies 4. Spread the top of the outer conductor. 4-2. Insert the body into the cable between outer conductor and aluminum foil tape. (Note)Center conductor is caught in the contact slit enough. (Note)Aluminum foil tape is inserted in the body. Body 5 5. Cover the ferule on the naked outer conductor. 5-1. Crimp the ferule. (Crimping Dies : RFD-1) (Note)The gap between body and ferule is within 0.5. Ferule Soldering 6 6. Solder the contact with center conductor. Contact Blind Screw 7 7. Screw up the blind screw on the body. Screw torque 9.8N・cm(1Kgf・cm) ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 17 DM Series Unit:mm ○ Assembly Instruction(11) Blind Screw Washer Parts Configuration Gasket FErule 1 Body L2 1. The cable length require for the cable assembly. L=L1+0.6 =L2-3.4 1-1. Insert the ferule into the cable. L1 Ferule Cable 2 Insulator Center Conductor Outer Conductor Pre-soldering +0.5 6.0 0 0 +0.5 10.0 0 3 2.0 -0.5 Contact Slit Spread the top 3. Spread the top of the outer conductor. 3-1. Insert the body into the cable between outer conductor and insulator. (Note)The center conductor is caught in the contact slit enough. Body Crimping Dies :D-P 4 2. Cut the cable as fig.2. (Note)Please be careful to not damage the center conductor and outer conductor. 2-1. Pre-solder the center conductor. 0.5 max. Ferule 4. Cover the ferule on the naked outer conductor. 4-1. Crimp the ferule. (Crimping Dies :D-P) (Note)The gap between body and ferule is within 0.5. 1∼1.5 (gap between dies and body) Soldering 5 5. Solder up the contact with center conductor. Contact Blind Screw 6 Washer 6. Insert the gasket, washer and blind screw. And screw up the blind screw. Screw toque・・・9.8 ∼ 19.6N・cm (1 ∼ 2Kgf・cm) Gasket ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 18