SMC Type Coaxial Connector

SMC Type Coaxial Connector
27DS Series
CONFORMING STANDARD
MIL−PRF−39012
Frequency
Range
DC to 1GHz
Characteristic
Impedance
50 Ω
FEATURE
◆ 27DS series are connectors produced based on
SMC type (Sub miniature type C) specified inMIL-PRF-39012.
◆ Super small size coaxial cable connectors for 50 Ω group corresponding
to minimization of communication equipment.
◆ Recommendation coupling torque : 24.5 ~ 35.3 N・cm
SPECIFICATIONS
Characteristic Impedance
Rated Voltage
50 Ω
335VAC(r.m.s.) Dielectric Withstanding Voltage 1,000V AC(r.m.s.) for 1minute
Insulation Resistance
1,000M Ω min. at 500V DC
Contact Resistance
6m Ω max.
V.S.W.R.
1.2 max. at DC to 1GHz
Operating Temperature
-40 〜 +85℃
* The specifications are typical but may not apply to all connectors. Please check
the specifications on each item with its drawing from us when you use.
RoHS
MATERIAL/FINISH
Compliant
Compliant
Item
Material / Finish
Shell (Body)
Copper Alloy / Ni or Au Plating
Contact (Male)
Copper Alloy / Au Plating
Contact (Female)
Copper Alloy / Au Plating
Insulator
PTFE
※ Please ask us for the cable assemblies to assure its performance.
◎ Specifications and/or dimensions in this catalog are subject to change without notice.
Your checking the latest specifications with our drawings would be highly appreciated.
121226
http://www.ddknet.co.jp
27DS Series
Unit:mm
○ Plug
Applicable
Cable
Part Number
φ6
φ4
27DS-P-1.5-CF
1.5D-QEV
1.5D-2V
27DS-P-196U-CF
RG-196A/U
Part Number
Applicable
Cable
Finish
Assembly
Outer
Center Instruction Crimp Tool
Conductor Conductor
Ni
Au
1
CR-H-1101
Ni
Au
1
CR-H-1101
16.3
○ Right Angle Plug
27DS-LP-1.5-CF
1.5D-QEV
1.5D-2V
Ni
Au
2
CR-H-1101
Ni
Au
2
CR-H-1101
11.85
φ6.0
27DS-LP-196U-CF RG-196A/U
Finish
Assembly
Outer
Center Instruction Crimp Tool
Conductor Conductor
φ4
6.35
13.9
○ Bulkhead Jack
Applicable
Cable
φ4
Part Number
27DS-BJ-1.5-CF
11
1.5D-QEV
1.5D-2V
Panel Thickness : 3.0 Max.
(17)
+0.1
3.2 0
+0.1
1.2 0
+0.1
φ5.2 0
Panel Mounting Hole
◎ Specifications and/or dimensions in this catalog are subject to change without notice.
Your checking the latest specifications with our drawings would be highly appreciated.
http://www.ddknet.co.jp
2
Finish
Assembly
Outer
Center Instruction Crimp Tool
Conductor Conductor
Ni
Au
1
CR-H-1101
27DS Series
Unit:mm
Part Number
φ0.6
φ6
○ Receptacle
27DS-BR-CF
Finish
Outer
Conductor
Center
Conductor
Ni
Au
Panel Thickness : 2.8 Max.
10.7
(14.9)
+0.1
3.2 0
+0.1
1.2 0
+0.1
φ5.2 0
Panel Mounting Hole
Part Number
27DS-R-PC-CF
Finish
Outer
Conductor
Center
Conductor
Ni
Au
Panel Thickness : 3.0 Max.
4.65
4.65
17.2
17.2
+0.1
+0.1
5-φ1.2 0
2.54 0.05
5.08 0.1
+0.1
φ5.2 0
2.54 0.05
+0.1
φ5.2 0
5.08 0.1
5-φ1.2 0
5.08 0.1
2.54 0.05
2.54 0.05
5.08 0.1
Panel Mounting Hole
PCB Mounting Dimensions
Panel Mounting Hole
PCB Mounting Dimensions
◎ Specifications and/or dimensions in this catalog are subject to change without notice.
Your checking the latest specifications with our drawings would be highly appreciated.
http://www.ddknet.co.jp
3
27DS Series
Unit:mm
○ Assembly Instruction((1)
①
Sheath
① Cut the cable as fig.1.
A
Cut off in the A size from an end face of a cable.
Please be careful to not damage the outer
conductor.
Outer Conductor
Ferrule
② Insert Ferrule
②
1)At 1.5D-2V and 1.5D-QEV, an application cable
puts a ferrule in inside outside covering.
2)Application cable is RG-196A/U, a ferrule inserts
Ferrule
B
until bump against covering outside the cable.
C
③ Stretched to loosen the cable braid, covers the extent
③
to Trim the outer ferrule wrap.
Center Conductor
Next Dimension B, C (see Table interfere dimension)
(Pre-soldering)
B
so that, except off to adhere to the wound center
C
conductor of the cable insulation. Central Conductor soldered.
Center Conductor
(Pre-soldering)
④ Soldering of Central Contact
Insulator
④
Solder up the contact with the center conductor.
Soldering
Please be careful to not deform the insulator by heat.
When the solder is stick out, please shave the extra
solder. No gap between contact and insulator ofthe
Contact
Heat-shrinkable tube
cable. Let the cable through the shrinkage tube.
No gap
Dies:B
⑤
⑤ Insert the assembly into the body until it hits those
Cable
Body end face
assembled, make sure the position of the contact center.
Crimp the edge according to dies assembled body
and face as shown on left and then using a special
Body Assembly
tool.
⑥ To protect a cable attaching portion at the end, please
⑥
cover, heat and fix heat-shrinkable tubing like a left figure.
Heat-shrinkable tube
■ Dimension table interfere
Part Number
0
A
B
27DS-P-1.5-CF
6.4
2.4
1.6
27DS-P-196U-CF
5.4
2.4
1.6
27DS-BJ-1.5-CF
8.0
2.4
2.4
◎ Specifications and/or dimensions in this catalog are subject to change without notice.
Your checking the latest specifications with our drawings would be highly appreciated.
http://www.ddknet.co.jp
4
C -0.4
27DS Series
Unit:mm
○ Assembly Instruction(2)
①
Sheath
① Remove outer covering.
23
Insert the boot into the cable and cut the cable as fig.1.
Please be careful to not damage the outer conductor.
Outer Conductor
②
Ferrule
② Insert Ferrule
(1) 1.5D-2V and 1.5D-QEV, an application cable
puts a ferrule in inside outside covering.
Ferrule
(2)Application cable is RG-196A/U, a ferrule inserts
until bump against covering outside the cable.
③
2.5
③ Stretched to loosen the cable braid, covers the extent
Center Conductor
to Trim the outer ferrule wrap.
Central Conductor isn't damaged, the insulator of the
cable is cut and removed like next becoming the size as
2.5
fig.3. Center Conductor
④ Put a thermal contraction tube through the of the
cable Put the tip of the center conductor through
⑤
④
Insulator ①
Soldering
the hole of the main body of connector.The part
where covered a ferrule with and braiding is inserted
until bump in the connector body, crimp in the same
way as the above using an exclusive tool.
⑤ Insulator(1) is shown into a central conductor of a
cable and inserted in the connector, and makes sure
that the of the Insulator(1) will fit into the insulator of
the cable.
sure that pulling the loose end of the center conductor
⑥
Insulator ②
length of 1.5mm to be the size of the tip Cut the pre soldering.
Central contact is forced and pays attention and solders so that I may hit an insulator(1) closely.
Boot
⑥ Maintain insulator ② for a contact; is the main body
of combination department on the top protests and
tightens it with a spanner firmly. Cover it with a heatshrinkage Boot like a left-hand
figure and fix it. ◎ Specifications and/or dimensions in this catalog are subject to change without notice.
Your checking the latest specifications with our drawings would be highly appreciated.
http://www.ddknet.co.jp
5